Minimum thicknesses and cables types
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter based
on the actual power draw from the connected devices and according to the CEI EN 60204-1 standards.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual
power draw and distances.
When connecting products that are not specified in this manual, please follow the documentation provided with said
products.
Connections
Cable Type
Cable Length
1 < 10 m
Cable Length
10 < 20 m
Cable Length
20 < 30 m
230V 2F power supply
FROR CEI
20-22
CEI EN
50267-2-1
3G 1,5mm²
3G 2,5mm²
3G 4mm²
230V 2F motors
4G 1mm²
4G 1,5mm²
4G 2,5mm²
230V fl ashing lamp
2 x 0,5mm²
2 x 1mm²
2 x 1,5mm²
230V cycle / courtesy lamps
3G 0,5mm²
3G 1mm²
3G 1,5mm²
Power for 24V accessories
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
24V pilot lamp
2 x 0,5mm²
2 x 0,5mm²
2 x 1mm²
Safety contacts
2 x 0,5mm²
2 x 0,5mm²
2 x 0,5mm²
N.O./N.C. command keys
2 x 0,5mm²
2 x 0,5mm²
2 x 0,5mm²
End-stop
2 x 0,5mm²
2 x 1mm²
2 x 1,5mm²
Aerial connection
RG58 - max. 10 m
Encoder connection
Shielded cable
2402C 22AWG - max. 5 m