L
N
U
V
W
X
Y
E
E3
10 11
S
1
2
3
3P
4
5
7
2
C1 CX B1 B2
TS 10
L1T
CT
0
12 24
L2T
2
FC1 FA2 FC2
FA1
L2T
L1T
1
2
3
4
0
12
24
L
N
U
V
W
X
Y
E
E3
10 11
S
1
2
3
3P
4
5
7
2
C1 CX B1 B2
TS 10
L1T
CT
0
12 24
L2T
2
FC1 FA2 FC2
FA1
L2T
L1T
1
2
3
4
0
12
24
L
N
U
V
W
X
Y
E
E3
10 11
S
1
2
3
3P
4
5
7
2
C1 CX B1 B2
TS 10
L1T
CT
0
12 24
L2T
2
FC1 FA2 FC2
FA1
L2T
L1T
1
2
3
4
0
12
24
L2T
L1T
1
2
3
4
p.
10
- M
an
u
al
FA
0
1
07
9
-E
N
- 1
0
/2
0
2
0 © C
A
M
E S
.p.
A
. - T
ra
n
sl
ati
on of th
e o
rig
in
al
in
str
u
cti
on
s
Selector
1 ON Automatic closing enabled (1 OFF-disabled);
2 ON "Open-stop-close-stop" with button (2-7) and radio-control (AF card fi tted) enabled;
2 OFF“Open-close” with button (2-7) and radio control (AF card fi tted) enabled; 3 ON
“Only open” and radio control (AF card fi tted) enabled (3 OFF-disabled);
4 ON Pre-fl ashwhen opening and closing enabled (4 OFF- disabled);
5 ON Obstruction detection enabled (5 OFF-disabled);
6 OFF “Maintainedaction” (excludes the radio control from functioning) disabled (6
ON - enabled);
7 ON Final jolt enabled; at each opening and closing command, the gate leaves jolt inwards
for a second, to help release the electric lock connected to terminals 11-S. It is active
only if the leaves are closed at the end of the operating time, or at the fi rst maneuver after
powering up the system (7 OFF - disabled);
8 OFFTerminal CX enabled (8 ON - disabled);
9 ON Ten-second slow-down disabled (9 OFF - enabled );
10 ON Photocellstest enabled (10 OFF disabled).
Selector
1 ON Limit switches enabled (1 OFF - disabled);
2 OFF CX withreclose while opening function;
2 ON CX with partialstop function.
TRM2
= To set the closing delay on Motor 2 from a minium of 0 seconds
to
a maximum of 15 seconds, and simultaneously the partial opening from
a
minimum of 0 seconds to a maximum of 30 seconds.
ACT
= To set the automatic closing time from a minimum of 1 second to
a
maximum of 120 seconds.
Adjusting the motor torque
To vary the motor torque, move the show faston to one of
the four positions:
1 min., 4 max..
Trimmer adjusting
Flashing in quick
succession
Slow-down
speed
1
minimum
2
medium
3
maximum
For adjusting the slow-down speed (perform procedures only when gate is
stopped):
•
set DIP-switch 6 to ON;
•
by pressingCH 1, the red
LEDwill show the set slow-down
speed (see table);
•
by againpressing CH 1 it shifts to the next speed;
•
confirmthe choice by pressing CH2;
•
resetDIP-switch 6 to OFF.
Adjusting slow-down speed
OT
= To set the operating time to a minimum of 10 seconds and a
maximum of 120 seconds.
Functions selection