CAME ZA3N Installation Manual Download Page 3

p. 

3

 - M

an

u

al

 

FA

0

1

07

8

-E

N

 - 0

2

/2

0

18 © C

A

M

E S

.p.

A

. - T

ra

n

sl

ati

on of th

e o

rig

in

al

 in

str

u

cti

on

s

• All maintained-action switches that are connected to the control panel must be po-
sitioned so that the maneuvering area is completely visible from the switches, yet far 
enough away from any moving parts. • Make sure that the operator has been properly 
adjusted and that any associated safety and protection devices, as well as the gearmo-
tor's manual release, are working properly. • If the power-supply cable is damaged, it 
must be replaced by the manufacturer or by the licensed technical-assistance center or 
by duly trained, skilled staff, to prevent any risks. • During all phases of the installation 
make sure you have cut off the mains power source. • The electrical cables must run 
through corresponding tubes or conduits to ensure suitable protection against mecha-
nical damage and they must not come into contact with parts that could heat up during 
use. • Make sure you have set up a suitable dual pole cut off device along the power 
supply that is compliant with the installation rules. It should completely cut off the power 
supply according to category III surcharge conditions. • If the control panel is used for 
automating guided parts in residential settings, permanently fit the entrapment-hazard-
warning signage, so that it is clearly visible or close enough to all command and control 
devices. After installing, make sure that the operator is properly adjusted and that the 
guided part, in case it touches any object that is 50 mm high off the ground, reverses 
its movement or that the object may easily be removed (for operators that have built-in 
anti-entrapment systems that depend on coming into contact with the lower edge of 
the guided part). Also make sure that the guided part does not extend onto any public 
pedestrian passages or onto the street. • Store this manual inside the technical folder, 
along with the installation manuals of the other devices in the system. Remember to 
hand over to the end users all the operating manuals of the products that make up the 
final machinery.

Summary of Contents for ZA3N

Page 1: ...Control panel for 230Vgearmotors ZA3N INSTALLATION MANUAL EN English FA01078 EN...

Page 2: ...te any guided part that includes a pedestrian gate unless the latter can be activated only when the pedestrian gate is secured Make sure the anchoring spot is clear of any potential impacts that the a...

Page 3: ...Make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation rules It should completely cut off the power supply according to category...

Page 4: ...table The card providesand controls the following functions automatic closing following an opening command pre flashingby the movement indicator light obstructiondetection when gate is not moving at...

Page 5: ...ted internally Colour of thetransformer and condenser cables white red black orange purple light blue Description of parts 1 Connection terminals 2 Control board fuses 3 Fuse for control devices and a...

Page 6: ...57 IEC whereas indoors use H05VV F type cables that conform to 60227 IEC 48V 53 IEC When powered up to you may use FROR 20 22 II type cables that conform to standard EN 50267 2 1 CEI For the Encoder u...

Page 7: ...otor with delayed opening Electolock connection 12V 15W max Terminals for powering the 24VA C accessories Control panel 230V A C 50 60 Hz ELECTRICAL CONNECTIONS AND PROGRAMMING Input voltage Gearmotor...

Page 8: ...n made on the DIP switches see selecting functions DIP switches 2 and 3 Key switch selector and or opening button N O contact For commanding the gate to open Stop button N C contact For commandingthe...

Page 9: ...to ON Safety devices with DIP switch 8 OFF DIP switch 10 OFF with DIP switch 8 OFF DIP switch 10 ON Connection for reclosing during opening N C contact With safety devices such as photocells sensitive...

Page 10: ...osingcommand thegateleavesjoltinwards forasecond tohelpreleasetheelectriclockconnectedtoterminals11 S This is active only if the leaves are closed and at the end of the operating time or at the rst ma...

Page 11: ...ontrol board AFTER CUTTING OFF THE MAINS POWER SUPPLY N B The control board recognizes the radiofrequency card only when it is powered up Saving CH1 Channel for direct commands to a feature of the gea...

Page 12: ...SPOSAL Always make sure you comply with local laws before dismantling and disposing of the product The packaging materials cardboard plastic and so on should be disposed of as solid household waste an...

Reviews: