If an error occurs, operating mode «A» and error display «E» light up alternately and an error code such as E 012 is displayed. The LED changes to red,
the 4 most recent errors are stored and can be interrogated.

Display

E001

E002

E011

E012

E101

E201

E301

E302

E311

E312

Error

Interruption
Loop 1

Interruption
Loop 2

Short circuit
Loop 1

Short circuit
Loop 2

Under-
voltage

EPROM
Error

Loop 1
too large

Loop 2
too large

Loop 1
too small

Loop 2
too small

Briefly pressing the «Data» button shows the last of 4 errors on the display. Another short press switches to the error before that,
and so on. When the button is pressed for the 5th time, the device switches back to automatic mode. If you press the «Data» button
for 2 seconds during the query, all error messages are deleted. The figure shows memory slot 1 in which error 001 Interruption loop
1 has been stored (example).

5

Determination of the number of loop turns

6

Troubleshooting

7

Reset

8

Most important technical data

Mode
Sim1

2 seconds

Reset 1 (recalibration)

The loop(s) is/are recalibrated.

Mode
Sim1

8 seconds

Data
Sim2

Reset 2 (factory setting)

All values are reset to the factory settings (see Table 4.1a). The
loop(s) is/are recalibrated.

For conformity reasons, in any situation, the antenna factor defined as the loop surface multiplied by the number of turns
should not exceed NA = 20

max.

50

mm

For example, if L = 2m, Ea = 1m and the number of turns = 4, then the NA = 2x1x4 = 8 < 20.
Find hereafter the recommended values for the turns:

Area

Number of turns

< 3 m

2

4

3-5 m

2

3

6-10 m

2

2

Profondità della scanalatura

Loop

sealant

30 - 50 mm depending
on cable turns number

Clean and dry slots prior
to inserting cable

Supply voltage
SMA, SMA2

24 VAC –20 % to +10% 84 mA
24 VDC –10 % to +20% 84 mA

Supply voltage
SMA 230

94–240 VAC ± 10%, 50/60 Hz,
23 bis 12 mA

Power consumption

max. 2 VA

Loop resistance

< 8 Ohm with connection wire

Loop inductance

max. 40–1000 µH,
ideally 80–300 µH

Loop connection wiring

max. 25 m 1,5 mm

2

min. 20x/m

Output relay (loop)

240 VAC/2 A AC1

Output relay (alarm)

60 VAC, 0.3 A, AC1

Dimensions

22.5 x 94 x 88 mm (W x H x D)

Operating temperature

–20°C to +60°C

Connection type

Plug-in terminals

Storage temperature

–40°C to +70°C

Protection class

IP 30

Air humidity

<95% non-condensing

All data checked with the maximum care. However, no libality is accepted for any error or omission.
The declaration of conformity and other technical documentation are available on our website www.came.it – BUY-TO-SELL PRODUCT

CAME

CANCELLI AUTOMATICI S.P.A.
Via Martiri Della Liberta, 15
31030 Dosson di Casier
Treviso -

ITALY

Phone (+39) 0422 4940
Fax

(+39) 0422 4941

Assistenza Tecnica
Numero Verde
Phone 800 295830
Web: www.came.com
E-Mail: [email protected]

69

26

-0

6-

02

88

b

01

/1

0

25

94

16

www.c

ame.co

m

C

od

ic

e

m

an

ua

le

:1

19

R

T2

0-

EN

ve

r.

3.

0

01

/2

01

0

©

C

A

M

E

ca

nc

el

li

au

to

m

at

ic

is

.p

.a

.

Reviews: