Safety instructions

1

These devices and their accessories may only be operated in compliance with the operating instructions (intended use)!
These devices and their accessories may only be commissioned by trained and qualified personnel.
These devices may only be operated with the intended operating voltages and parameters.
If malfunctions occur that cannot be rectified, shut down the device and send it in for repair.
These devices are only allowed to be repaired by the manufacturer. Tampering and alterations are not permitted. This will invalidate all guarantee and
warranty claims.

The loop connection wiring to the loop detector must be twisted at least 20 times per meter.
Please wire the device in accordance with the terminal assignment. Make sure the terminals are assigned correctly.

1

LOOP DETECTOR

Documentazione

Tecnica

T20

rev. 3.0

01/2010

©

CAME

CANCELLI

AUTOMATICI

119RT20-EN

SMA - SMA 2 - SMA 230

E

N

G

L

IS

H

Operating instructions for Installing and Start-up

(Translation)

Mounting and electrical connection

SMA is mounted directly onto a standardized 35-mm mounting rail.
The terminals for all connections are coded pluggable terminals.

2

Supply voltage

Loop connection

1-channel device

Loop connection

2-channel device

Alerting

Output

2nd output

+/~

–/~

A1
A2

L3
L4

L3
L4
L5
L6

1

2

31
32
34

common
nc

no

14

11
12

common
nc

no

24

21
22

common
nc

no

Relay response to malfunctions (see chapter 6 Troubleshooting):

General

Explanation of the LCD display

Explanation of the LED

Standard display
1-loop device

Standard display
2-loop device

Control button

Control button

1

1

2

Mode
Sim1

Data
Sim2

1

2

Loop 2,
output 2

Example:
Parameter «h»
set

Function

Example:
Time
function set

Loop 1, output 1

Info

Red:

Start-up phase

Green:

Operation

Red & green:

Configuration

Flashing green:

Loop activated

Flashing red:

Error

Flashing red + green:

Simulation

The settings of the devices in this chapter are shown and explained for the 1-loop device. The settings for loop 2 of a 2-loop device should be made using
the corresponding method.

1.Door/gate

systems

A malfunction causes
the output relay to be
released. The alarm
relay drops out.

2. Barrier

A malfunction causes
the output relay to pick
up. The alarm relay
drops out.

3. Quiescent

current

A malfunction causes the
output relay to be
released. The alarm relay
drops out.

4. Direction logic

(2-loop device
only)

A malfunction causes
the output relays to be
released. The alarm
relay drops out.

Parameters
1: Door and gate

The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.

2: Barrier

The assigned output relay picks up when the loop is activated and drops out when the loop returns to a non-activated condition.

3: Quiescent current

The assigned output relay drops out when the loop is activated and picks up again when the loop returns to a non-activated condition.

4: Direction logic

Output 1 switches if an object moves from loop 1 to 2. Output 2 switches if an object moves from loop 1 to 2.

Both loops

must be

activated for a short time. The outputs are reset again when loop 2 returns to a non-activated condition. Both loops must have re-
turned to a non-activated condition for another direction detection.

0: Loop 2

Loop 2 / output 2 can be deactivated in a 2-loop device.

3

Value and parameter setting options

LCD display and controls

3.1

Basic functions

0

(see Table 4.1a for settings)

3.2