F1 Total stop [1-2]
0 = Deactivated (
default
) / 1 = Activated
NC input – Gate stop that excludes any automatic closing; to resume movement, use the control device. The
safety device is inserted into [1-2].
F2 Input
[2-CX]
0 = Deactivated (
default
) / 1 = C1 / 2 = C2 / 3 = C3 / 4 = C4 / 7 = C7
/ 8 = C8
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by
photocells, C3 = partial stop, C4 = obstruction wait, C7 = reopening during closing by sensitive safety-edges,
C8 = reclosing during opening by sensitive safety-edges.
F3 Input
[2-CY]
0 = Deactivated (
default
) / 1 = C1 / 2 = C2 / 3 = C3 / 4 = C4 / 7 = C7
/ 8 = C8
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by
photocells, C3 = partial stop, C4 = obstruction wait, C7 = reopening during closing by sensitive safety-edges,
C8 = reclosing during opening by sensitive safety-edges.
F5 Safety
test
0 = Deactivated (
default
) / 1 = CX / 2 = CY / 4 = CX+CY
After every opening or closing command, the board will check whether the photocells are working properly.
The safety test is always active for wireless devices.
F6 Maintained
action
0 = Deactivated (
default
) / 1 = Activated
The gate opens and closes by keeping the button pressed. Opening button on contact 2-3P and closing button
on contact 2-7. All other control devices, even radio-based ones, are excluded.
F7 Command
[2-7]
0 = Step-step (
default
) / 1 = Sequential
From the control device connected to 2-7 it performs the step-step (open-close-invert) or sequential (open-stop-
close-stop) command.
F8 Command
[2-3P]
0 = Opening (
default
) / 1 = Partial opening
From the control device connected to 2-3P it performs the total opening (0) or partial opening (1) of the gate.
The partial opening time is adjusted on function F 71.
F9 Obstruction detection with
motor idle
0 = Deactivated (
default
) / 1 = Activated
With the gate closed, opened or totally stopped, the gearmotor stays idle if the safety devices, that is, photocells
or sensitive safety-edges detect an obstruction.
F10 Gate-.open signal output
0 = lit when gate is open or moving (
default
) /
1 = when opening it fl ashes intermittently every half-second,
when closing it fl ashes intermittently every second,
stays lit when gate is open
is off when gate is closed
It signals the gate status. The signal device is connected to contact 10-5.
F11 Encoder
0 = Activated (
default
) / 1 = Deactivated
Functions menu
IMPORTANT! Start programming by fi rst performing the following: MOTOR-TYPE SETTING (A1), OPENING
DIRECTION (F54), TOTAL STOP (F1) and TRAVEL CALIBRATION (A3)
⚠
Programming the features is to be done when the operator is stopped.
You can memorize up to 25 users.