ZLJ14 & 24 

1.

 

Insert all wires between motors and CB, Set limits on operators, Insert AF43S card 

2.

 

Connect lead to L and N, turn power on 

3.

 

To enter the MENU, press and hold <

ENTER

> for at least ONE SECOND 

4.

 

Scroll to LANGUAGE <

ENTER

> select ENGLISH <

ENTER> ESC, ESC

 

5.

 

Scroll to FUNCTIONS <

ENTER

6.

 

Scroll to AUTOCLOSE <

ENTER

> select DISABLED <

ENTER

7.

 

Scroll to TOTAL STOP <

ENTER

> select DISABLED <

ENTER

8.

 

Scroll to CX <

ENTER

> select DISABLED <

ENTER

9.

 

Scroll to CY <

ENTER

> select DISABLED <

ENTER

> (CZ disabled ex-factory) 

ESC

ESC

 

10.

 

Scroll to IMP.RUN <

ENTER

> MOTOR TYPE <

ENTER

> set your motor <

ENTER

ESC, ESC

 

11.

 

Scroll to ENCODER <

ENTER

12.

 

Scroll to SENSIB. RUN <

ENTER

> select half the dots <

ENTER

13.

 

Scroll to SENSIB.DECEL<

ENTER

> select half the dots<

ENTER

14.

 

Scroll to SET ENCODER <

ENTER

> select CONFIRM YES <

ENTER

ESC, ESC

 

 

TO ADD USERS 

15.

 

Scroll to USER <

ENTER

16.

 

Scroll to ADD USER <

ENTER

> scroll to ADD USER CONFIRM YES <

ENTER

> scroll to 

RELATED FUNCTIONS <

ENTER

17.

 

You can now press the Tx button 

18.

 

Repeat to add further users. Clone to add further remotes to each User slot. 

ESC, ESC

 brings you back to the home screen of 

www.came.it

 (wait for 30 seconds to go out of 

programming mode) 

You can change the home screen by going to INFO <

ENTER

> scroll to STANDBY MSG. <

ENTER

insert new msg. <

ENTER

> hold for at least ONE SECOND 

 

 

Summary of Contents for SDN Series

Page 1: ...confirm 3 The next available user slot between 1 25 will start to flash Press and release the remote button to be programmed 4 Press Esc to exit programming You can clone this code from remote to remo...

Page 2: ...ully and set the RED cam to the CLOSED position always close onto the body of the micro switch not to the spring 6 Open the gate fully and set the WHITE cam to the OPEN position 7 Set all the pots to...

Page 3: ...3W 2 7 Open Close dipsw 2 3 off Open stop close stop dipsw 2 on Open only dipsw 3 on Open only dipsw 2 3 on SAFETY Anything with a C is for safety C1 Reopening dipsw 9 C3 Partial Stop dipsw 10 C7 Saf...

Page 4: ...sert all wires between motors and CB unlock motor using trilobed key 2 Set limits on operators lock motor using trilobed key 3 Insert AF43S card 4 Connect power lead to L and N terminals turn power on...

Page 5: ...TER 9 Scroll to CY ENTER select DISABLED ENTER CZ disabled ex factory ESC ESC 10 Scroll to IMP RUN ENTER MOTOR TYPE ENTER set your motor ENTER ESC ESC 11 Scroll to ENCODER ENTER 12 Scroll to SENSIB RU...

Page 6: ...installed F46 Number of Motors select 0 for 2 motors or 1 for single motor on M2 A2 Motor Test change to 1 then press and hold which will activate the M2 motor Next press and hold the for the M1 moto...

Page 7: ...FF ENTER STOP 1 ENTER select OFF ENTER CX ENTER select DISABLED ENTER CY ENTER select DISABLED ENTER CZ OFF ex factory RADIO USERS ENTER scroll to NEW USER ENTER scroll to RELATED FUNCTIONS ENTER You...

Page 8: ...1 Block 2 10 OFF 2 7 DIP 3 ON ZL92 MENU MENU SETTINGS 2 7 ZL180 7 8 ON 1 2 Bridged 7 OFF 2 7 DIP 3 ON ZLJ 14 24 MENU MENU SETTINGS 2 7 ZN7 A1motor A3 configure F2 2 3P DUPLICATING THE TRANSMITTER CLON...

Page 9: ...If the arm goes down the motor polarity is reversed and the M Brown N Blue terminals need to be swapped Also swap the limit switch terminals FA White FC Red AUTOMATING THE BARRIER CAME Remotes Turn o...

Page 10: ...ic Gates Access Control Parking Equipment Bollards CAME Australia Pty Limited ABN 31 116 251 024 Unit 55 11 21 Underwood Road Homebush NSW 2140 T 02 9746 9991 F 02 9746 8891 W www came com au AMICO IN...

Page 11: ...atic Gates Access Control Parking Equipment Bollards CAME Australia Pty Limited ABN 31 116 251 024 Unit 55 11 21 Underwood Road Homebush NSW 2140 T 02 9746 9991 F 02 9746 8891 W www came com au AXO IN...