ENGLISH
2.1 Intended use
This symbol shows parts which must be read with care.
This symbol means the parts which describe safety issues.
This symbol tells you what to tell the end-user.
The complete TRA04 system is for commanding 230 V AC mono-phase automated operators
Any installation and use other than that specified in this manual is forbidden.
"IMPORTANT INSTALLATION SAFETY INSTRUCTIONS"
“WARNING: IMPROPER INSTALLATION MAY RESULT IN SERIOUS HARM. PLEASE FOLLOW ALL INSTALLATION INSTRUCTIONS”
“THIS MANUAL IS INTENDED ONLY FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT INDIVIDUALS”
2.2 Application settings
Engineered and built entirely by Came Cancelli Automatici
S.p.A.
The TRA04 kit includes:
-1
ZR24
: control panel;
-1
AF43S
: snap-in radio card;
-1
TOP432NA
: two-channel radio transmitter.
The two-channel radio transmitter can be used to command
rolling shutter, industrial shutters and retracting awning
operators.
The card is powered by 230 V AC on terminals L1 and L2, and
should be input protected by a 5 A fuse, while the 24 V - low
voltage accessories - are protected by a 1 A fuse.
Warning! The overall power of the 24 V accessories must not
exceed 5 W.
All connections are protected by quick fuses, see table.
The card provides and controls the following functions:
- automatic closing after an opening command;
- maintained action command.
The available command modes are:
- opening/closing;
- open-stop-close-stop;
- total stop.
The photocells, after detecting an obstacle, may trigger:
- the reopening of the closing gate;
- a total stop.
Special trimmers regulate:
- the working time for automatic closing;
- the working time.
Came Cancelli Automatici employs an ISO 9001 certified quality management system and an ISO 14001 environmental
management system. Came only engineers and manufactures in Italy.
This product is compliant with:
see statement of compliance.
The overall power load of the connected motor must not exceed 500W.
F U S E TA B L E
to protect: fuses for:
Electronic board (line)
A 5
Accessories
1 A
T E C H N I CA L DATA
line voltage
230 V
Maximum allowed power load
500 W
power draw when idle
15 mA
maximum power for 24 V accessories
5 W
circuit insulation class
container material
ABS
container protection rating
IP54
working temperature
-20 / +55°C
Legend of symbols
2 Conditions of use
3 Reference standards
4 Description
You can also connect:
- courtesy - lamp lighting the parking area for opening/
closing cycle.