LED-SIGNALS

The ORANGE LED 
fl ashes 1 x.

The ORANGE LED 
fl ashes 2 x.

The ORANGE LED 
fl ashes 4 x.

The ORANGE LED 
fl ashes 5 x.

The ORANGE LED 
fl ashes quickly.

The ORANGE LED 
is on.

The RED LED fl ashes 
quickly after an 
assisted setup.

The RED LED 
lights up 
sporadically.

The GREEN LED 
lights up 
sporadically.

The LED is off.

The reaction of 
the door does not 
correspond to the 
LED-signal.

A DIP-switch was changed 
without confi rmation.

The sensor signals 
an internal fault.

Irregularities in the 
power supply

The sensor receives 
not enough IR-energy.

The sensor receives 
too much IR-energy.

The sensor encounters 
a memory problem.

The sensor vibrates.

The sensor sees the door 
during the assisted setup.

The sensor sees the door.

The sensor is disturbed by 
lamps or another sensor.

The sensor is disturbed 
by the rain.

The sensor is disturbed by 
rain and/or leaves.

The sensor vibrates.

Ghosting

The sensor sees the door 
or other moving objects.

Check power supply.
Check wiring.

Use the 1 m prism if possible (accessory). 
Check the angle of the IR-curtains.

Confi rm the DIP-settings by a long push on the 
push button.  

Cut and restore power supply.  
If orange LED lights up again, replace sensor.

Check the angle of the IR-curtains.
Launch a new assisted setup.

Attention: Do not stand in the detection fi eld!

Change the activation mode of relay R1 (DIP 4).

Use a low energy prism if possible (accessory). 
Check the angle of the IR-curtains.

Check if the sensor is fastened fi rmly.
Check position of prism and cover.

Choose the critical environment presetting (DIP 1+2).

Choose the critical environment presetting (DIP 1+2).

Choose the critical environment presetting (DIP 1+2).

Change radar antenna angle.

Check if the sensor is fastened fi rmly.
Check position of cable and cover.

Remove the objects if possible.
Change radar fi eld size.

Launch an assisted setup and adjust the IR angle.

Cut and restore power supply.
If orange LED fl ashes again, replace sensor.

Check connections to test output.
If your door controller is not able to test the sensor, 
connect the red and blue cable to the power supply.*

 

SAFETY INSTRUCTIONS

The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC. 

Only trained and qualifi ed personnel may install and setup the sensor. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Avoid 
touching any electronic and optical components.

M

R

82

04

 / F

A

00

02

5M

06 

O

riginal

 in

st

ru

ct

ion

s

 V

IO

-D

T2 / 4

2.

82

74 / v

2 - 0

2.

15

Came S.p.A. hereby declares that MR8204 is in conformity with the basic requirements and the other relevant provisions 
of the directives 1999/5/EC, 2004/108/EC and 2006/42/CE.
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment 
(WEEE)
Original upon request.

BUY

-

TO

-

SELL

 

PRODUCT

Reviews: