background image

4

5

+

+

- Test the good functioning of the installation before leaving the premises.
- The device cannot be used for purposes other than its intended use. All other uses cannot be guaranteed by the manufacturer 
  of the sensor.  
- The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system 
  in compliance with applicable national and international regulations and standards on door safety. 
- The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor. 
- Only trained and qualifi ed personnel may install and setup the sensor. 
- The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. 
- Avoid touching any electronic and optical components, avoid vibrations, do not cover the sensor and avoid proximity to 
  neon lamps or moving objects.
- It is recommended to clean the optical parts at least once a year or more often if required due to environmental conditions.

PRESETTINGS

ENVIRONMENT

RELAY R1 ACTIVATION

SAFETY INSTRUCTIONS

TIP

Launch an 

ASSISTED SETUP

 to verify wiring, position of the 

curtains and correct functioning of the sensor.

SETTINGS 

(by DIP-switch)

QUICK SETUP

ASSISTED SETUP

SETUP

Step outside of the infrared fi eld before launching a setup.

LONG (> 3s)

SHORT

standard

critical

environment

shopping

street

1

hospital

2

standard

extreme

3

Can only be used if DIP 4 is OFF.

Not available on MR8204. If selected, the presetting «standard» is applicable.

3

 Enhanced IR-immunity which excludes EN 16005-conformity of the door system.

4

 The opening relay (R1) is activated in case of detection in the radar or infrared fi eld.

motion

 or 

presence

4

motion

After changing a DIP-switch, the orange LED fl ashes. 
A LONG push on the push button confi rms the setting.

Always launch a setup after changes of the DIP-settings.

LONG (> 3s)

critical environment

: enhanced immunity (rain, snow, lamps...) and only 1 IR-curtain activated.

shopping street

: optimized for narrow sidewalks > the opening relay (R1) is activated in case of detection in radar + IR-fi eld.

hospital

: optimized for persons with reduced mobility (PRM)

standard

: standard environments (factory setting)

OFF

RED-GREEN

RED-GREEN

OFF

OFF

OPEN+CLOSE

ORANGE

M

R

82

04

 / F

A

00

02

5M

06 

☜☞

 V

IO

-D

T2 / 4

2.

82

74 / v

2 - 0

2.

15

Reviews: