ELECTRICAL CONNECTIONS AND PROGRAMMING
🅳
⚠
Before proceeding, cut off the main power supply.
DIP SWITCHES for fitting the terminator resistor
🅴
The terminator resistor is used to balance the Bus cable over long
distances. Normally the resistor is fitted to the last devices (the
farthest) connected along the bus line.
To plug the terminator resistor set DIP switch 2 to ON (2 OFF is
the default setting).
Setting the DIP switches on the interface card
🅵
The DIP switch is set for selecting the I/O card's ID and
assigning a univocal address to the device connected on the
serial Bus.
FINAL OPERATIONS
🅶
Once the electrical connections are done fasten the cover using
the screws.
DISMANTLING AND DISPOSAL
Always make sure you comply with local laws before
dismantling and disposing of the product.
DO NOT DISPOSE OF IN NATURE!
The contents of this manual may be changed at any time without
prior notice.