p.
18
- Manual
FA01354-EN
- 07/2019 - © C
AME S.p.A. - The cont
ents of this manual may change, at any time, and without notice. - Original instructions
PROGRAMMING
Function of the programming buttons
3
2
1
1
ESC button
The ESC key is used to perform the operations described below.
Exiting the menu
Delete the changes
Return to the previous screen
Stop the operator
2
< > buttons
The <> keys are used to perform the operations described below.
Navigate through the menu items
Increasing or decreasing values
Close or open the operator
3
ENTER button
The ENTER key is used to perform the operations described below.
Accessing menus
Confirm the choice
Temporary stop
It stops the boom and excludes the automatic closing; after 15 seconds the boom opens slowly.
F1
Temporary stop
OFF (Default)
ON
CX input
It associates a function with the CX input.
F2
CX input
OFF (Default)
C1 = Reopening while closing (Photocells)
C4 = Obstacle wait (Photocells)
C5 = Immediate closing at the opening travel end
C7 = Reopening while closing (Sensitive safety-edges)
C9 = immediate closing at the travel end during opening with obstacle waiting, during
closing
C10 = Immediate closing during opening with obstacle waiting during closing
r7 = reopening while closing (Sensitive safety-edges with 8K2 resistor)
CY input
It associates a function with the CY input.
F3
CY input
OFF (Default)
C1 = Reopening while closing (Photocells)
C4 = Obstacle wait (Photocells)
C5 = Immediate closing at the opening travel end
C7 = Reopening while closing (sensitive safety-edges)
C9 = immediate closing at the travel end during opening with obstacle waiting, during
closing
C10 = Immediate closing during opening with obstacle waiting during closing
r7 = reopening while closing (sensitive safety-edges with 8K2 resistor)