background image

3

A

ll t

h

e d

at

a a

n

d i

n

fo

rm

at

io

n c

o

n

ta

in

ed h

er

ei

n

 i

s c

o

n

si

d

er

ed

 s

u

b

je

ct to c

h

an

g

e a

t a

n

y t

im

e a

n

d a

t o

u

r d

is

cr

et

io

n

ENGLISH

4.2 Technical information

—#

—#

8

4.3 Parts description

AUTOMATION UNIT

ACCESSORIES

VIEW FROM THE BAR 

SUPPORT BRACKET

VIEW FROM INSPECTION 

HATCH

 1)

 Upper dome

 2) 

Bar beam plate

 

 3) 

Bar fitting intermediate plate

 4) 

Cover for semioval aluminium bar

 5) 

Anti-shearing protection cover 

 6) 

Sheet-steel or stainless steel cabi-

net with galvanized and painted finish  

 7) 

Inspection hatch

 8) 

Gearmotor

 9) 

ABS container for electric 

board with transformer 

9

7

1

2

3

4

5

6

GEARMOTOR 

Power supply: 230V A.C. 50/60Hz
Motor power supply: 24V D.C. 50/60Hz
Max. absorption: 1.3A (230V) / 15A (24V) 
Rated power: 300W
Max. torque: 600 Nm
Reduction ratio: 1/202

Opening time: 2÷6 s
Operative intermittence: intensive operation
Protection level: IP54
Weight: 54 kg
Insulation class: I

 1) 

G03750 - Semioval aluminium bar, painted white L = 4 m.

 2) 

G03752 - Oval aluminium bar, painted white L = 4 m.

 3) 

G02040 - Ø40 (yellow) balancing spring

 

4) 

G04060 - Ø50 (green) balancing spring

 5) 

G06080 - Ø55 (red) balancing spring

 

6) 

G0465 - Rack

 7) 

G02802 - Support for DIR photoelectric cells

 

8) 

G02803 - Luminous cord

 

9) 

G02807 - Fixed barrier support

10) 

G02808

 

- Mobile barrier support

11) 

G02809 - Adhesive reflector strips

12) 

G02801 - Flashing dome lamp

13) 

G03751 - Emergency battery housing support

14) 

ZL38 - Electric board designed to accommodate radio board coupling

15) 

G03753 - cover for oval aluminium bar

CAME

CAME

CAME

CAME

:,

7

12

11

8

9

10

14

2

3

4

6

5

13

1

15

Summary of Contents for GARD 4 SERIES

Page 1: ...AUTOMATION FOR STREET BARRIERS INSTALLATION MANUAL GARD 4 SERIES G4040 G4040I...

Page 2: ...L38 Electric board designed to accommodate radio board coupling 002 LB38 Board for the connection of three 12V 6Ah emergency batteries The following accessories are optional to the GARD 4 automation s...

Page 3: ...50 60Hz Max absorption 1 3A 230V 15A 24V Rated power 300W Max torque 600 Nm Reduction ratio 1 202 Opening time 2 6 s Operative intermittence intensive operation Protection level IP54 Weight 54 kg Insu...

Page 4: ...it continuity are allowed as long as they include additional insulation with respect to other internal drive parts Install suitable tubes and ducts for electric cable passage to guarantee protection a...

Page 5: ...ls 2 1 7 3 4 5 6 8 8 Photoelectric cells 9 Fixed barrier support 10 Magnetic sensor 11 Photoelectric cell support 12 Magnetic reader 13 Column for reader 9 10 11 12 13 5 3 Cable list and minimun thick...

Page 6: ...e a hole to house the fixing base and prepare sheath tubes from the branch pit for the connections 4 Remove the nuts and washers from the threaded screws position the cabinet on the base in correspond...

Page 7: ...designed to be installed on the left of the gateway as seen from inside 3 Should installation on the right be required the direction of the bar s opening must be inverted Proceed in the following man...

Page 8: ...insert it in the bar s conduit a procedure that should be carried out on both sides Insert the shock resistant profile and cut excess length Lastly secure the bar end plug with the screws provided 4 P...

Page 9: ...resistant profile and mobile barrier support Barebar shock resistantprofile luminouscordandmobilebarriersupport Bare bar rack and mobile barrier support Bare bar luminous cord rack and mobile barrier...

Page 10: ...n anchor nut 4 Hook the tie rod to the anchoring bracket release the gearmotor and manually turn the spring to increase or decrease traction until the bar rests at 45 WARNING The release procedure may...

Page 11: ...is loose when the bar is in the vertical position at rest the spring is tight when the bar is in the horizontal position tense 5 7 ZL38 Electric board installation 1 Loosen the three screws in the con...

Page 12: ...cessary proceed to the adjustment of the dampers Warning For greater safety and better unit performance the bar s opening and closing operations should be carried out with the inspection hatch closed...

Page 13: ...g and closing adjustment tighten the locking nuts under the dampers 5 Insert the inspection hatch and close it 4 After making adjustments and settings from the control panel put the container lid in p...

Page 14: ...ower The unit does not work with the back up batteries 8 25 26 15 Check the bar length ratio with mountable accesso ries The unit is slow to respond 7 16 Re save radio code 18 Adjust sensitivity 22 En...

Page 15: ...parts of the following Standards 98 37 CE 98 79 CE MACHINERY DIRECTIVE 98 336 CEE 92 31 CEE ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 73 23 CEE 93 68 CE LOW VOLTAGE DIRECTIVE 89 106 CEE CONSTRUCTION PR...

Page 16: ...Cod 119GT80 ver 0 2 06 06 CAME CANCELLI AUTOMATICI CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431...

Reviews: