TROUBLESHOOTING
PROBLEM
REFERENCE
CHECK
The boom neither opens nor closes
1-2-3-4-6-8-
13-18
1 - Lock the inspection hatch with the key
The boom opens but does not close
4-7
2 - Deactivate the MAINTAINED ACTION function
The boom closes but does not open
4-7-12-13
3 - Check the power supply and fuses
The barrier does not perform automatic closing
11-12-13
4 - The NC contacts are open
The barrier does not work with the transmitter
2-14-16
6 - Deactivate the MASTER-SLAVE function
The boom's direction of travel is inverted
7-18
7 - Check the boom's balancing and spring tautness
Only one transmitter works
22
8 - Deactivate the OBSTRUCTION DETECTION function
The photocells do not work
12-23-24
11 - Activate the AUTOMATIC CLOSING function
The warning LED flashes quickly
4
12 - Check the proper direction of travel
The warning LED stays lit
13
13 - Check the control devices
The boom does not reach the endstop
7
14 - Replace the AF card
The boom cannot be balanced
7-15
15 - Check the length ration between boom and applied
accessories
The barrier does not slow down
7-15
16 - Memorize the radio code again
The barrier does not work with emergency batteries
8-25-26
18 - Adjust the sensitivity
The boom starts slow
7
22 - Enter or duplicate the same code on all transmitters
23 - Activate the photocells
24 - Connect the photocells serially instead of in parallel fashion
25 - Check the batteries
26 - Respect the photocell's power supply polarities
Er1
The boom travel calibration was interrupted by the activation of the STOP button.
Er3
Encoder is broken.
Er4
Services test error.
Er5
Insufficient working time
Er6
Maximum number of obstructions detected.
Er7
Transformer overheating.
Er8
The inspection hatch is open.
C0
Contact 1-2 (NC) is open.
C1, C4, C5 or C9
The (NC) contacts are open.
The warning LED
flashes
The control board is not yet calibrated for the boom travel.
ERROR MESSAGE
The error messages appear on display and are notified by LEDs
.
Summary of Contents for G2080EZ
Page 33: ...Automatic barriers GARD 8 series G2080EZ INSTALLATION AND OPERATION English FA01038 EN...
Page 65: ...Barri res automatiques s rie GARD 8 G2080EZ MANUEL D INSTALLATION Fran ais FA01038 FR...
Page 97: ...GARD 8 G2080EZ FA01038 RU...
Page 98: ...2 FA01038 RU 1 01 2018 CAME S p A Came S p 2 5 20 CE 1 8 1 5 EN 12453 EN12445 8...
Page 103: ...7 FA01038 RU 1 01 2018 CAME S p A 24 600...
Page 104: ...N M 8 FA01038 RU 1 01 2018 CAME S p A 90 M N...
Page 105: ...UNI5931 M8x20 UNI5931 M8x12 UNI5931 M8x20 UNI6954 2 9x13 9 FA01038 RU 1 01 2018 CAME S p A...
Page 107: ...11 FA01038 RU 1 01 2018 CAME S p A 45 UNI5739 M12x70 UNI5588 M12...
Page 114: ...18 FA01038 RU 1 01 2018 CAME S p A 89...
Page 122: ...Z L 3 8 26 FA01038 RU 1 01 2018 CAME S p A...