ELECTRICAL CONNECTIONS
Before working on the control panel, cut off the mains power supply and remove the batteries, if any.
To access the terminal block, remove the protective cover.
Input voltage
1
Blue cable
2
Purple cable
3
Orange cable
4
Red cable
5
Black cable
6
White cable
To vary the motor torque, move the corresponding faston
terminal to one of the four positions; from 1 (minimum) to 4
(maximum).
Accessories power supply output
7
Output delivers normally 24 V AC.
Maximum power 20 W.
8
Electric lock 12 V - 15 W max
9
230VAC-50-60HZ power supply
24V
C1 7 2 1 11 10 ES ES
12V 0
CT
L
N
L2T L1T
2LT
1LT
1
2
3
0
12
24
4
1
2
3
4
5
6
7
8
9
Connecting up the gearmotor