1
0
-
F
A01584M4A - 02/2022 - © CAME S.p.A.
Getting started
Once the electrical connections have been made, proceed with commissioning. Only skilled and qualifi ed staff may perform this operation.
Make sure that there are no obstacles in the way.
Power up and proceed with the operations indicated below.
A1 - Motor type
F46 - Number of motors
A2 - Motor test
> open the M2 leaf
< open the M1 leaf
Check that both leaves open. If they do not, invert M and N on the relevant terminal.
F2 - CX input
F3 - CY input
F72 - Limit-switch function*
F73 - Input type FC/FA**
A8 - Motor power**
A3 - Travel calibration
*Only with end-of-travel microswitches used.
**Only with generic motor [Function A1 set at 0].
If “A1” scrolls across the display, this means the type of motor must be set before any other parameters can be modifi ed.
If “A3” scrolls across the display, calibrate the travel. The panel does not accept motion commands, except for the motor test (A2).
Complete programming and check the warning and safety devices are working properly.
After powering up the system, the fi rst manoeuvre is always to open the gate Wait for the manoeuvre to be completed.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the system.
Summary of Contents for FA01584M4A
Page 2: ...2 FA01584M4A 02 2022 CAME S p A Installazione...
Page 8: ...8 FA01584M4A 02 2022 CAME S p A Installation...
Page 14: ...14 FA01584M4A 02 2022 CAME S p A Installation...
Page 20: ...20 FA01584M4A 02 2022 CAME S p A...
Page 23: ...23 FA01584M4A 02 2022 CAME S p A 1 2 Enter 3 F50 F51...
Page 24: ...24 FA01584M4A 02 2022 CAME S p A E1 1 E2 2 E3 E4 E7 E9 E10 E11 E12 E13 E15 E17 E18 E24 E25...