If the services test function has been set on the CAME control panel, connect the TX
photocells to terminals 10 and TS, instead of 10 and 11, on the control panel.
For the OUT output contacts, always check the connection and function instructions
in the relevant CAME control panel manual.
For installations alongside photocells of a diff erent type, we recommend
installing TX transmitters and RX receivers alternately, as shown in the fi gure
F
Status warning LED
LED
RX-TX photocell alignment
1 fl ash per second
weak
2 fl ashes per second
suffi cient
3 fl ashes per second
good
On
excellent
③
Operation on TX signal
Photocell pairs
Slow fl ash
Quick fl ash
1 synchronised pair
TX1
-
2 or more synchronised
pairs
TX1
from TX2 to TX8
⑥
Active output on RX signal
LED
Message
On
Output idle
Off
Output active