Sensor type
Set the type of control device.
F14
Sensor type
0 = Transponder selector switch
1 = Keypad selector (default)
Additional light
Choose the operating mode of the lighting device connected to the output.
F18
Additional light
0 =Flashing beacon (Default)
1 = Cycle light.
The light remains off if an automatic closing time is not set.
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
F19
Automatic close
OFF (Default)
From 1 to 180 seconds
Automatic closing after partial opening
Set the time before automatic closure is activated, after a partial opening command has been performed.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
Do not deactivate the function [Automatic close].
F20
Automatic partial close
OFF
From 1 to 180 seconds (default: 10 seconds)
Pre-flashing time
Set the time for which the beacon is activated before each manoeuvre.
F21
Pre-flashing time
OFF (Default)
From 1 to 10 seconds
Opening slowdown speed
Set the slowdown speed during opening (as a percentage of the maximum speed).
This function appears only if the [Encoder] function is active.
F30
Opening slowdown speed
OFF (Default)
1 = High
2 = Medium
3 = Low
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
This function appears only if the [Encoder] function is active.
F34
Travel sensitivity
10% to 100% (Default 100%) - 10% = maximum sensitivity - 100% = minimum
sensitivity