9
Functions
Terminal boards
+
Power supply
14-18 VDC
–
BOUT
Riser
Solenoid lock
12 V - 1 A max
–
Door lock release button (NA)
Door contact input (NC)
–
Ground
Entry panel enabling output (active towards earth)
–
Ground
Connectors
CN2:
Connector for the keyboard or RFID access control module.
CN4:
Additional push button panel connector.
MINI USB:
Programming connector.
Adjustments
loudspeaker audio
microphone audio
solenoid lock 1-10 s. (default 1 s)
Signals
Red - Call in progress
Green - Door open
Yellow - Conversation in progress
Blue - System busy
Programming
The entry panel is supplied already confi gured through a call put through
to any receiver that has NEVER been programmed.
It is possible, however, to add buttons or receivers as explained in the entry
panel’s programming manual.
The VA/01 power supply unit automatically recognises the entry panel
connected the fi rst time the ‘self-connection’ button is pressed. The power
supply unit is programmed after a couple of seconds.
L
M1
CN4
M2
CN2
DATI
MINI USB
OUT
BOUT
PROG
KIT FREE DC-DVC 24810380 16-09-14_EN