Functions map
F 1
Total stop function (1-2)
F 2
Function associated to input 2-CX
F 3
Function associated to input 2-CY
F 4
Function associated to input 2-CZF 5 Safety test function
F 6
Maintained action function
F 7
Control mode on 2-7
F 9
Obstruction detection with motor idle function
F 10
Warning light function
F 11
Encoder exclusion
F 14
Sensor type selection function
F 18
Additional light function
F 19
Automatic closing time
F 20
Automatic closing time after partial opening
F 21
Preflashing time
F 22
Working time
F 25
Courtesy light time
F 30
Adjusting gearmotor slow-down speed
F 34
Sensitivity during movement
F 35
Sensitivity during slow-down
F 36
Adjusting partial opening
F 37
Adjusting the gearmotor's opening slow-down starting point
F 38
Adjusting the gearmotor's closing slow-down starting point
F 49
Managing functions
F 50
Saving data in the memory roll
F 51
Reading memory roll data
F 52
Passing settings in paired/alternating mode
F 54
Opening direction
F 56
Peripheral number
F 63
Changing COM speed
F 71
Partial opening time
U 1
Entering new user with an associated command
U 2
Deleting single users
U 3
Deleting all users
A 3
Calibrate gate run
A 4
Reset settings
A 5
Counting the number of maneuvers
H 1
Software version
IMPORTANT! Begin programming by first performing the following functions: OPENING DIRECTION (F54), TOTAL STOP (F1) and
TRAVEL CALIBRATION (A3).
⚠
Programming the features is to be done when the operator is stopped.
You can memorize up to 25 users.
Functions menu
F1
Total stop [1-2]
0 = Deactivated (
default
) / 1 = Activated
NC input – Gate stop that excludes any automatic closing; to resume movement, use the control device. Fit the safety device onto [1-2].
F2 Input
[2-CX]
0 = Deactivated (
default
) / 1 = C1 / 2 = C2 / 3 = C3 / 4 = C4 / 7 = C7 / 8 = C8
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive safety-edges.
F3 Input
[2-CY]
0 = Deactivated (
default
) / 1 = C1 / 2 = C2 / 3 = C3 / 4 = C4 / 7 = C7 / 8 = C8
NC input – Can associate: C1 = reopening during closing by photocells, C2 = reclosing during opening by photocells, C3 = partial stop, C4 =
obstruction wait, C7 = reopening during closing by sensitive safety-edges, C8 = reclosing during opening by sensitive safety-edges.