background image

LINE  
FUSE 

ON 

3  4  5  6  7  8  9  10 

L1T  L2T  CT  VS  VF 

W  E1 

24 

12 

 

10  11 

TS 

3P 

C1  C3 

EB  EB 

FC  FA 

+ A. C.T. -

+ PAR.OP - 

ELECTRIC 

BLOCK 

1.6A 

BOARD 315mA 

ACCESSORIES 

1A 

BATTERY 1.6A 

CONTROL 

BOARD 

ZBK8 

AF1 

AF2 

CH1 

 

ON

OFF

/.

       

LINE  
FUSE 

ON 

3  4  5  6  7  8  9  10 

L1T  L2T  CT  VS  VF 

W  E1 

24 

12 

 

10  11 

TS 

3P 

C1  C3 

EB  EB 

FC  FA 

+ A. C.T. -

+ PAR.OP - 

ELECTRIC 

BLOCK 

1.6A 

BOARD 315mA 

ACCESSORIES 

1A 

BATTERY 1.6A 

CONTROL 

BOARD 

ZBK8 

AF1 

AF2 

CH1 

 

p. 

1

4

14

 - M

an

u

al

F

A

0

0

6

0

5

-E

N

FA

0

0

6

0

5

-E

N

 v.

 

1

- 0

1/

2

0

17 - © C

A

M

E S

.p.

A

. - T

h

e c

onte

nts of th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed, at a

ny ti

m

e, a

n

d w

ith

ou

t n

oti

ce

.

Features selection

Settings

Trimmer Description of functions

PAR. OP.

Partial opening

It regulatesthe gate's opening time.

By pressing on the partial opening button on 2-3P, the gate will open for a interval of 1 to 15 seconds.

A.C.T.

Automatic Closing Time

It sets the open gate's waiting time. Once this time elapses, a closing maneuver is automatically performed.
The waiting time can be set to between 1 and 140 seconds.

DIP-SWITCH Description of functions

1 ON

AUTOMATIC CLOSING (1 OFF - deactivated)

2 ON

OPEN-STOP-CLOSE-STOP from button on 2-7 and/or from transmitter (with AD card fitted)

2 OFF

OPEN-CLOSE-INVERT from the button on 2-7 and/or from a transmitter (with AF card fitted)

3 ON

ONLY OPEN from button 2-7 and/or from transmitter (with AF card fitted)

4 ON

MAINTAINED ACTION (4 OFF - deactivated)

5 ON

PRE-FLASHING when opening and closing (pre-flashing duration: 5 seconds) (5 OFF - deactivated)

6 ON

OBSTRUCTION DETECTION when motor is idle (6 OFF - deactivated)

7 OFF

REOPEN WHEN CLOSING (7 ON - deactivated)

8 OFF

PARTIAL STOP (8 ON - deactivated)

9 ON

RUNNING THE SAFETY TEST (9 OFF - deactivated)

10 OFF

TOTAL STOP (10 ON - deactivated)

Summary of Contents for BK-1200P

Page 1: ...INSTALLATION MANUAL BK 1200P OPERATOR FOR SLIDING GATES FA00605 EN English EN ...

Page 2: ...AT THE PHOTOCELLS ARE FREE OF ANY OVERGROWN VEGETATION AND THAT THE OPERATOR S AREA OF OPERATION IS FREE OF ANY OBSTRUCTIONS DO NOT ALLOW CHILDREN TO PLAY WITH FIXED COMMANDS OR TO LOITER IN THE GATE S MANEUVERING AREA KEEP ANY REMOTE CONTROL TRANSMITTERS OR ANY OTHER COMMAND DEVICE AWAY FROM CHILDREN TO PREVENT THE OPERATOR FROM BEING ACCIDENTALLY ACTIVATED THE APPARATUS MAY BE USED BY CHILDREN O...

Page 3: ...tment blocks alike Any installation and or use other than that specified in this manual is forbidden Limits to use Type BK 1200P Max gate leaf weight kg 1 200 Maximum door leaf length m 14 Pinion module 4 This symbol shows which parts to read carefully This symbol shows which parts describe safety issues This symbol shows which parts to tell users about LEGEND Intended use Technical data Type BK 12...

Page 4: ...r 3 Control board 4 Front cover 5 Anchoring plate 6 Control board holder 7 Limit switch fins 8 Mechanical limit switch 9 Fan 10 Transformer 11 Release hatch 12 Release key Standard installation 1 Operator 2 Limit switch fins 3 Rack 4 Key switch selector 5 Flashing light 6 Antenna 7 Photocells 8 Photocells post 9 Mechanical gate stop 10 Sensitive safety edge 11 Junction pit ...

Page 5: ...gh making sure they are protected from any mechanical damage Cable types and minimum thicknesses Connection Cable type Cable length 1 15 m Cable length 15 30 m 230 V AC power supply to control panel H05RN F 3G x 1 5 mm2 3G x 2 5 mm2 Flashing light 2 x 0 5 mm2 Photocell transmitters FROR CEI 20 22 CEI EN 50267 2 1 2 x 0 5 mm2 Photocell receivers 4 x 0 5 mm2 Command and safety device 2 x 0 5 mm2 Pai...

Page 6: ...inforce the concrete Fit the bolts into the fastening plate and tighten them using the nuts Remove the pre shaped clamps using a screw driver or pliers If the rack is already there place the anchoring plate being careful to respect the measurements shown in the drawing Careful The tubes must pass through their corresponding holes Fill the foundation frame with concrete The plate must be perfectly ...

Page 7: ...e electric cables into the tubes so that they come out about 600 mm Setting up the operator Remove both covers Place the gearmotor above the anchoring plate Careful The electric cables must pass under the gearmotor case Lift the gearmotor by about 5 to 10 mm from the plate adjust the threaded rests to allow for future adjustments between the pinion and the rack ...

Page 8: ... RELEASING THE GEARMOTOR paragraph rest the rack above the gearmotor pinion weld or fasten the rack to the gate along its entire length To assemble the rack modules use an extra piece and rest it under the joint then fasten it using two clamps Adjusting the pinion rack coupling Manually open and close the gate and adjust the pinion rack coupling distance using the threaded feet vertical adjustment...

Page 9: ...otor to the plate using the plates and nuts Establishing the limit switch points For opening open the gate fit the opening limit switch tab onto the rack until the micro switch activates spring and fasten it using the grub screws Spring 20 mm For closing close the gate fit the closing limit switch fin into the rack until the micro switch is activated spring and fasten it using the grub screws 20 mm ...

Page 10: ... card slot for Pratico System 12 Battery fuse 1 6 A 13 Control unit fuse 315 mA 14 Electric lock fuse 1 6 A 15 Signal LEDs 230 V 16 Electric lock limit switch and accessory connection terminals 17 PRATICO SYSTEM radio code signal LED 18 Button for memorizing the PRATICO SYSTEM radio code ZBK8 TECHNICAL DATA Power supply voltage 230 V 50 60 Hz Absorption when idle 38 mA Accessories maximum power lo...

Page 11: ...230 V AC frequency 50 60 Hz Eyelet with screw and washer for ground connection Closing micro switch Changes to the electrical connections for installing on the right Invert the U V gearmotor phases and the FA FC limit switch phases Opening micro switch Description of the electrical connections is the same as that for installing on the left Condenser Motor 230V AC Orange Orange Red Red White White ...

Page 12: ...ntrol button or any other control device If unused set DIP switch to ON ONLY OPEN function from control device NO contact OPEN STOP CLOSE STOP sequenziale function or OPEN CLOSE INVERT step by step from a control device NO contact See selecting functions DIP switches 2 and 3 PARTIAL OPENING feature from command device NO contact Adjustable via PAR OP trimmer ONLY CLOSE function from control device...

Page 13: ... triggers an inversion of movement until it is wide open IMPORTANT When the safety test function is activated the NC contacts if unused should be excluded by their corresponding DIP switches see the Selecting functions paragraph Connecting the safety devices i e the safety test At each opening and closing command the control board checks the efficacy of the safety devices such as photocells Any ma...

Page 14: ...2 3P the gate will open for a interval of 1 to 15 seconds A C T Automatic Closing Time It sets the open gate s waiting time Once this time elapses a closing maneuver is automatically performed The waiting time can be set to between 1 and 140 seconds DIP SWITCH Description of functions 1 ON AUTOMATIC CLOSING 1 OFF deactivated 2 ON OPEN STOP CLOSE STOP from button on 2 7 and or from transmitter with...

Page 15: ...terminal connected to the battery into the motherboard connector For the memorization procedure the board must be battery powered Check that the LED signaling the 230 V power supply is switched off Disconnect the 230 V power supply and fit the AF radio card into slot AF2 the mother board recognizes it only when it is battery powered Press and keep pressed key on the base board the alert LED will fla...

Page 16: ...F card only when it is the mains power supply is restored C Keep pressed the CH1 key on the control board the alert LED will flash D Press any key on the transmitter to send the code the LED will stay on to signal that memorization is now complete Repeat C D for any other transmitter buttons ACTIVATING THE RADIO CONTROL Make all the electrical connections only on the control board of motor CONNECT...

Page 17: ... and 3 to ON on both boards For opening with the radio command connect an external receiver RExxx RBExxx with relay switch in MONOSTABLE mode to terminals 2 3 of gearmotor Connect the two control boards as shown in the figure Make the same adjustments and activate the same functions on both boards FINAL OPERATIONS Do the final operation only once the connections are complete and the system is starte...

Page 18: ...TING ISSUES POSSIBLE CAUSES FIXES It neither opens nor closes Power supply missing The gearmotor is stuck The stop button is either stuck or broken The opening closing button or the key switch selector is stuck The transmitter does not work the battery is flat Photocells in partial stop mode Check main power supply Lock the gearmotor Call for assistance Call for assistance Replace the batteries of...

Page 19: ...aintenance log Fitter s stamp Name of operator Job performed on date Technician s signature Requester s signature Job performed __________________________________________________________________________________________ ______________________________________________________________________________________________________ ______________________________________________________________________________...

Page 20: ...follow these brief disposal guidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic and so on should be disposed of as solid household waste and simply separated from other waste for recycling Always make sure you comply with local laws before dismantling and disposing of the product DISPOSE OF RESPONSIBLY DISMANTLING AND DISPOSAL Our products are made of various materials ...