C1 partial stop.
Gate stops, if it is moving, and prepares to automatically close
(if this function is activated).
Configure contact C1 and/or C5
(NC), input for safety devices such
as photocells, which comply with
EN 12978 regulations.
Safety devices
C3 reopening during closing.
When gate is closing, opening the contact
triggers an inversion of movement until it is wide open.
IMPORTANT:
When the safety test function is
activated, the NC contacts - if
unused - should be excluded
by their corresponding DIP
switches (see the Selecting
functions paragraph).
Connecting the safety devices (i.e. the safety test)
At each opening and closing command, the control board checks the effi cacy of the safety devices (such as, photocells).
Any malfunction will inhibit any command and is signaled by the fl ashing (PROG) LED on the control board. It cancels any command from either
transmitter or button.
Electronic connection for running the photocells' safety test:
- both the transmitter and the receiver must be connected as shown in the drawing;
- set DIP-switch 9 to ON to activate the running of the test.