To enable the intercommunicating function, press the intercommunicating call button you want to call with on the internal receiver you 
want to program 

. A beep indicates that the function has been programmed successfully. Repeat for all of the other internal receiv-

ers to be included in the intercommunicating group. To conclude programming, press the PROG button on the entry panel briefl y 

.

NOTE. Once an internal receiver has been included in a group by assigning the intercommunicating call button, it cannot be 
excluded from this group. If you want to change the call button on an internal receiver which has already been programmed 
as an intercommunicating receiver, or you want to add new internal receivers to the group, repeat the operations detailed 
under “Programming an intercommunicating group”.

Enabling/disabling

Press the PROG button on the entry panel and hold for at least 20 seconds 

.

The red 

 and yellow 

 LEDs fl ash quickly for 3 seconds 

NOTE: If the intercommunicating function is disabled, follow this procedure to enable it, and vice versa.

The yellow LED 

 comes on for 2 seconds to show the function has been enabled, or the red LED 

 comes on for 2 seconds to show 

the function has been disabled.

NOTE. Program the intercommunicating group after assigning calls to all indoor receivers.

Programming an intercommunicating group

Press and hold the PROG button on the entry panel for at least 8 seconds and release within 11 seconds 

The red 

 and yellow 

 LEDs fl ash to show intercom programming is in progress 

.

RESTORING FACTORY SETTINGS

To restore the entry panel to the default settings (including the terminal functions 

), remove the power supply, press and hold 

the two call buttons on the unit and power the device.
After 5 seconds the entry panel restarts.

NOTE: if the entry panel does not restart, it has not been restored to factory settings.

Summary of Contents for AGTMTMVKIT

Page 1: ...AGTMTMVKIT AGT V M2 M1 VAS 101 MTMV 01 FA01481 EN INSTALLATION MANUAL AGT V MTM KIT IT Italiano EN English FR Fran ais RU P FA01481M04...

Page 2: ...ures as speci ed by the manufacturer The product must be installed programmed commissioned and serviced by quali ed technicians correctly trained with regard to respecting the regulations in force inc...

Page 3: ...escription Internal video receiver Function of terminals and jumpers Terminal board M1 B BUS line input Landing call AL Alarm input Closing resistance CL RES Master slave selector M S Technical data T...

Page 4: ...f the support Fix the wall support to the round 60 mm recessed box to the rectangular box 503 or to the Ophera PHI recessed box with the TOP arrow pointing upwards Avoid overtightening the screws Use...

Page 5: ...at any time and without notice Translation of the original instructions VCM 1D UTP CAT5 No Master 3 2 1 1 No Slave 0 3 7 3 VCM 1D VCM 2D UTP CAT 5 2x1mm2 2 x 2 5 mm2 La Lb 100 m 100 m Lc 25 m 60 m La...

Page 6: ...en to the melodies in sequence press To select the melody and exit the programming mode press To select the melody and continue programming press 3 Programming the melody associated with a call from t...

Page 7: ...for the unit for the hard of hearing Additional unit socket Terminal board cover For more information on the button and LED func tions please see the programming instructions Function of terminals MT...

Page 8: ...uctions REMOTE CONTROLLING CALL BUTTONS Manual configuration of terminals and as call inputs 1 and 2 Short circuit the terminals and press and hold the two call buttons on the unit and power the devic...

Page 9: ...any time and without notice Translation of the original instructions PROGRAMMING Programming for the first time Entering programming mode Press and hold the PROG button on the entry panel for at least...

Page 10: ...e basic module no call buttons a a you do not need to press the buttons that are shown as ashing in gure a a Once programming is complete you are automatically taken to programming calls Programming c...

Page 11: ...nal re ceiver to indicate that the function has also been enabled on the module NOTE If the module is programmed with the open gate function the door contact input terminal will function exclusively a...

Page 12: ...ness level of the entry panel light can be adjusted from any receiver Press the auto connection button on the internal receiver b b to activate the video camera on the entry panel for which you want t...

Page 13: ...oup repeat the operations detailed under Programming an intercommunicating group Enabling disabling Press the PROG button on the entry panel and hold for at least 20 seconds The red and yellow LEDs as...

Page 14: ...NOTE Ensure there is correct ventilation if the power supply is installed in a metal case Terminal board M1 Network Terminal board M2 Power supply output 18 V DC The device is electronically protecte...

Page 15: ...rence standards DISPOSAL Dispose of the packaging and the device at the end of its life cycle responsibly in compliance with the laws in force in the country in which the product is used The recyclabl...

Page 16: ...15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Page 16 Manual FA01481 EN 09 2020 CAME S p A The contents of this manual may be changed at any time and without notice Transl...

Reviews: