Programming the open-gate function 

An operator control can be connected to the module auxiliary 
relay and/or an operator status to the door status input.
From applicable, preconfi gured internal receivers, the relay can 
be controlled using the open-gate command and/or the operator 
status shown via the relevant LED on the internal receiver itself.
To confi gure the module with the open-gate function, enable the 
function on one of the connected internal receivers, by entering 
call programming (see previous paragraph), and send an open-
gate command from the internal receiver (press and hold the 
“key” button) as an alternative to or in addition to associating 
the call button. The open-gate LED lights up on this internal re-
ceiver to indicate that the function has also been enabled on 
the module. 
NOTE. If the module is programmed with the open-gate function, 
the “door contact input” terminal will function exclusively as an 
operator status indicator.
NOTE. This function is available from version 1.03.000 of the 
module software.
NOTE. You can force the switch from one programming mode to 
another by pressing the PROG button on the module unit for 3 
seconds and releasing within 6 seconds. If you force the switch 
to call programming from button programming, the button units 
which have not been programmed will be confi gured to 8 calls. 
If the basic module is not programmed, calls are not confi gured.

Exiting programming

 

Press the PROG button briefl y 

. The LEDs on the entry panel 

switch off .

Adjusting the brightness and colour of the module 
backlight 

During call programming 

 

, you can adjust the brightness 

and colour of the module backlight. Press the left call button to 
select white 

 

, and the right call button to select blue 

 ③

.

Press the same button repeatedly to select one of the fi ve bright-
ness levels (off , 25%, 50%, 75%, 100%).

Summary of Contents for AGTMTMVKIT

Page 1: ...AGTMTMVKIT AGT V M2 M1 VAS 101 MTMV 01 FA01481 EN INSTALLATION MANUAL AGT V MTM KIT IT Italiano EN English FR Fran ais RU P FA01481M04...

Page 2: ...ures as speci ed by the manufacturer The product must be installed programmed commissioned and serviced by quali ed technicians correctly trained with regard to respecting the regulations in force inc...

Page 3: ...escription Internal video receiver Function of terminals and jumpers Terminal board M1 B BUS line input Landing call AL Alarm input Closing resistance CL RES Master slave selector M S Technical data T...

Page 4: ...f the support Fix the wall support to the round 60 mm recessed box to the rectangular box 503 or to the Ophera PHI recessed box with the TOP arrow pointing upwards Avoid overtightening the screws Use...

Page 5: ...at any time and without notice Translation of the original instructions VCM 1D UTP CAT5 No Master 3 2 1 1 No Slave 0 3 7 3 VCM 1D VCM 2D UTP CAT 5 2x1mm2 2 x 2 5 mm2 La Lb 100 m 100 m Lc 25 m 60 m La...

Page 6: ...en to the melodies in sequence press To select the melody and exit the programming mode press To select the melody and continue programming press 3 Programming the melody associated with a call from t...

Page 7: ...for the unit for the hard of hearing Additional unit socket Terminal board cover For more information on the button and LED func tions please see the programming instructions Function of terminals MT...

Page 8: ...uctions REMOTE CONTROLLING CALL BUTTONS Manual configuration of terminals and as call inputs 1 and 2 Short circuit the terminals and press and hold the two call buttons on the unit and power the devic...

Page 9: ...any time and without notice Translation of the original instructions PROGRAMMING Programming for the first time Entering programming mode Press and hold the PROG button on the entry panel for at least...

Page 10: ...e basic module no call buttons a a you do not need to press the buttons that are shown as ashing in gure a a Once programming is complete you are automatically taken to programming calls Programming c...

Page 11: ...nal re ceiver to indicate that the function has also been enabled on the module NOTE If the module is programmed with the open gate function the door contact input terminal will function exclusively a...

Page 12: ...ness level of the entry panel light can be adjusted from any receiver Press the auto connection button on the internal receiver b b to activate the video camera on the entry panel for which you want t...

Page 13: ...oup repeat the operations detailed under Programming an intercommunicating group Enabling disabling Press the PROG button on the entry panel and hold for at least 20 seconds The red and yellow LEDs as...

Page 14: ...NOTE Ensure there is correct ventilation if the power supply is installed in a metal case Terminal board M1 Network Terminal board M2 Power supply output 18 V DC The device is electronically protecte...

Page 15: ...rence standards DISPOSAL Dispose of the packaging and the device at the end of its life cycle responsibly in compliance with the laws in force in the country in which the product is used The recyclabl...

Page 16: ...15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Page 16 Manual FA01481 EN 09 2020 CAME S p A The contents of this manual may be changed at any time and without notice Transl...

Reviews: