P
ag.
13
-
FA01497M4A
- 03/2021 - © C
AME S.p.A. -
Description
S0002P - External, two-channel, 12-24 V AC - DC IP54 control card for keypads and transponder.
Description of parts
❶
Save code key for channel 1 (OUT1)
❷
Save code key for channel 2 (OUT2)
❸
Delete all code key
❹
Warning LED
❺
Expansion board
❻
Terminals for channel outputs OUT1 and OUT2
❼
Power supply terminals
❽
Terminals for connecting accessories
Size
Installation
Fix the board container in a place protected from knocks.
The distance between the S0002P card and the keypad selector or transponder must be
max. 30 m.
Connections
Connect up the electrics as shown in the figure.
Connect up to 4 keypad selectors or 4 transponder selectors.
Use H05RN-F cables that are 60245 IEC 57 (IEC) compliant.
Incoming current protection / limitation of 500 mA is recommended.
Technical data
Type
806SL-0370
Power supply (V AC/DC)
12 - 24
Protection rating (IP)
54
Maximum power draw at 24V AC (mA)
350
Number of relay contacts
2*
24V DC max relay capacity (A)
1
Max. users
250**
Operating temperature (°C)
-20 to +55
Device class
III
* OUT1 = Monostable, OUT2 = configurable as Monostable (default) / Bistable / Hold-to-run.
** With the expansion board inserted.
Summary of Contents for 8K06SL-007
Page 1: ...806SL 0370 RU FR Fran ais EN English IT Italiano FA01497M4A...
Page 2: ...46 23 27 108 91 Pag 2 FA01497M4A 03 2021 CAME S p A...
Page 3: ...4 max 30 m Pag 3 FA01497M4A 03 2021 CAME S p A...
Page 26: ...Pag 26 FA01497M4A 03 2021 CAME S p A CAME S p A 2014 53 EU www came com...
Page 29: ...Pag 29 FA01497M4A 03 2021 CAME S p A 1 2 3 8 1 OUT2 1 20 3 1 1 2 3 8 3 3 8 10 OUT2 2 1 3 20...
Page 30: ...Pag 30 FA01497M4A 03 2021 CAME S p A OUT2 OUT2 S0002P S0002P 1 7 2 3 10 3 20 1 7 2 0 3 0 3 20...