background image

TITLE

7

 pre-installed

 sim card

The pre-installed SIM card is an IOT/M2M multi SIM complete with 480MB data allowance and 3 year life term. 
Under average usage of 3-4 gate manoeuvres per day, the data should last approximately 3 years.
In case you use up the 480MB data volume before the end of the 3-year term, you can easily add another 480MB data 
volume by making a top-up, details of which can be found here:

www.cameconnect.co.uk/gsmmodule

Due to situations outside of our control, CAME cannot guarantee signal strength or availability and therefore will not be 
held liable for lack of service.

came 

automation

internet

came 

cloud

setup app

for the installer

GET IT ON

App Store

GET IT ON

automation app

for the end user

GET IT ON

App Store

GET IT ON

System Frequency

Approx. Movements

Est. SIM Life Based on Usage

Occasional Usage

Approx. 5 gate manoeuvres per 

week

4-7 Years*

Average Usage**

Approx. 3-4 gate manoeuvres 

per day

3-4 Years

High Usage

Approx. 5+ gate manoeuvres per 

day, multiple scenarios running

1-3 Years

* SIM will expire after 3-4 years. (CAME guarantees 3 years with some tolerance for shelf life consideration)  

** We anticipate SIM provided will have suffi cient data for Average Usage (as shown above) lasting approx. 3 years   

8

 initial 

power ON

Power on the control board.

to check motor direction using

 control panel

CAUTION, Ensure the gate movement area is clear of all obstructions

Check the motor direction  

A

 

2

 

 – 

O

 

N

 

 

For motor 2, Press and hold

 

 

The gate should open, if not reverse the motor cables for motor 2 (Connections M2, N2) 

 

Leave the gate leaf in the halfway position.

For motor 1, Press and hold

 

 

The gate should open, if not reverse the motor cables for motor 1 (Connections M1, N1) 
Leave the gate leaf in the halfway position.

OUT1

OUT2

Keycode

123456789ABCDE F

MATR

54051 6

300mAE

GSM – 900  33dBm

DCS – 1800   30dBm

869.5MHz     14dBm  

24V

CONNECT

123

4

GND

A

N

T

10

+

2

COM

IN2

COM

IN1

B
A

 1A 30V

RGSM001S

1

2

1

     GSM LED (Blue)

    After a few seconds the LED will flash 1x/sec  

  indicating the RGSM001S is registered on a  
  GSM network.

2

     POWER LED (Green)

    The LED will flash 5x/sec indicating the  

  RGSM001S is not yet configured on the  
  Connect platform.

antenna bracket 

Fitting instructions

Make sure your kit 

contains the antenna, 

bracket and cable.

Remove the safety 

screw from the cable.

Tighten the safety 

screw until the cable is 

secure.

Screw the bracket 

into place using the 

two holes.   Do not 

screw into the plastic 

enclosure as this 

will invalidate your 

warranty.

Slot the cable into 

the single hole of the 

bracket and re-attach 

the safety screw.

Screw the antenna into 

place.

1

2

3

4

5

6

Installer Tip 

 If the RGSM001S is located 

in a concealed area and a 

low GSM signal observed, 

please use the supplied cable 

extension for the GSM aerial. 

This then allows the aerial to 

be located in a more suitable 

position.

Summary of Contents for 8K01MP-0408

Page 1: ...UIDE Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a pair of swing gates weighing up to 400kg per leaf max width 3m TO BE READ IN...

Page 2: ...RGSM001S Gateway Module RSE Connection Card SIM May be preinstalled in RGSM001S 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Wiring Diagram 7 Pr...

Page 3: ...sing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gates by remote control unless they are in view Do not attempt to block or interfere with the gate...

Page 4: ...lands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection ratin...

Page 5: ...mm 90 130 130 960 1220 50 90 150 220 910 1290 150 90 120 270 890 1300 200 120 180 130 910 1300 50 Preliminary checks Side hung gate GEOMETRY 3m Tick 1 Check that the gate structure is sturdy enough t...

Page 6: ...refully at the same speed as the automatic operator 4 To re engage close the gate and turn the key back to its original position D Attempt to manually move the gate to ensure it is fully engaged Basic...

Page 7: ...r to OFF TOP A433N Antenna Cable length RG58 Max 5m DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m 10 2 TX C NC TX 2 RX TX RGSM001S Gateway Module Cable length Max 3m pow...

Page 8: ...rength or availability and therefore will not be held liable for lack of service came automation internet came cloud setup app for the installer GET IT ON AppStore GET IT ON automation app for the end...

Page 9: ...SM LED Blue After a few seconds the LED will flash 1x sec indicating the RGSM001S is registered on a GSM network 2 POWER LED Green The LED will flash 5x sec indicating the RGSM001S is not yet configur...

Page 10: ...ceive an email containing your log in information and request to confirm the account Should the email not arrive please check your junk folder download the connect setup app adding the rgsm gateway to...

Page 11: ...2040825 Mr Wilson Maple Avenue Derby Front Gate 123456789ABCDEF WILSON DERBY 8988228066602040825 Mr Wilson Maple Avenue Derby Front Gate CAME RGSM Keycode 123456789ABCDEF 1NCE SIM No 89882280666020408...

Page 12: ...do this using the Installer Setup App The information can be found in the Gateway Information Device configured Online 123456789ABCDEF WILSON DERBY 8988228066602040825 Mr Wilson Maple Avenue Derby Fr...

Page 13: ...be on solid and the BLUE 1 flashing 1x sec CONGRATULATIONS the RGSM001S has now been successfully added to the Connect platform adding the rgsm gateway to your technician account continued 3 OUT1 OUT...

Page 14: ...en press Add adding automation 1 ZL65 ZL65 Automation for swing gates Activated Axo ATS M1 M2 Front Gates Front Gates 1 Installer Tip The Name and Description entered here can be used to identify the...

Page 15: ...ition or Add with QR Code If you pressed Local Acquisition the screen will change to the one shown here Select the button on the fob and it will add the button straight onto the control panel Set the...

Page 16: ...cess for all fobs Select the back button to return to the main menu If you select ADD via QR Code the app will open the devices camera enabling scanning of the QR code on the fobs packaging Once the Q...

Page 17: ...n App On first login you will be prompted to accept the gateway You will then be presented with control options for your automation To transfer to a customer select the 3 dots Select Transfer site Ent...

Page 18: ...open if not reverse the motor cables for motor 1 Connections M1 N1 Leave the gate in the halfway position 8 Setup the encoder A 3 O N The Gates will now perform a close and open cycle 9 Exit the progr...

Page 19: ...saved remove a transmitter button 1 Press and hold the button for 2 seconds to access programming F 1 appears on the display 2 Remove a transmitter button U 2 O N 3 Use the arrow buttons to choose the...

Page 20: ...quire activation from a command device to restart C1 REOPENING DURING CLOSING When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its m...

Page 21: ...it the replacement SIM card into the slot Replace the casing and power up the control panel Send an SMS to the telephone number of the SIM reporting the APN details Access Point Name ask the service p...

Page 22: ...colour 806SL 0240 SELB1SDG2 Surface mounted with blue backlighting for 50 users RAL7024 Grey colour 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour TRANS...

Page 23: ...to each other with no interference issues cross talk 001DIR10 Pair of 12 24 V AC DC outdoor photocells range 10m 001DIR20 Pair of 12 24 V AC DC outdoor photocells range 20m 001DIR30 Pair of 12 24 V AC...

Page 24: ...correct use of the Software requires the possession of an automation home automation security temperature control and or video surveillance system manufactured by Came which has been enabled for remo...

Page 25: ...ation of the automation home automation security temperature control and or video surveillance system manufactured by Came may be associated with the system itself In this way the installer can perfor...

Page 26: ...mediate effect in the event of the violation of the terms of Articles 2 2 and or 2 5 In this case termination shall occur automatically upon receipt by the Installer of the noti cation sent by Came wi...

Page 27: ...idual parts of the additional network services and other related services referred to in Section 3 1 lit c of these GTC 1NCE expressly points out that the type and scope of such services of the respec...

Page 28: ...ction 2 of these GTC for the Services Within the framework of the conclusion of the contract the Customer may choose between different payment methods offered by 1NCE Unless otherwise agreed between t...

Page 29: ...Protection Act Bundesdatenschutzgesetz 10 2The Parties also undertake to treat all other con dential information of the other Party that the receiving Party becomes aware of in connection with the co...

Page 30: ...TITLE notes...

Page 31: ...TITLE notes...

Page 32: ...House Maxted Road Maylands Ind Est Hemel Hempstead Herts HP2 7DX Tel 01442 230 800 CAME BPT Ireland Unit 9 The Westway Centre Ballymount Dublin 12 Tel 353 0 1 450 7442 8K01MP 0408 QS0922 2022 EN YOU...

Reviews: