4
GEOMETRY
• The greater the motor angle, the greater the opening
speed and the slower the gear motor’s thrust.
• The smaller the motor angle, the slower the opening
speed and the greater the gear motor’s thrust.
Opening
A (mm)
B (mm)
C (mm)
90
°
140 ÷ 210
540
0 ÷ 50
90
°
140 ÷ 200
510
75 ÷ 200
90
°
150 ÷ 180
510
225 ÷ 250
110
°
200 ÷ 220
480
0 ÷ 50
Preliminary checks
Side hung gate GEOMETRY
Tick
1. Check that the gate structure is sturdy enough, the hinges work efficiently and that there is
no friction between the fixed and moving parts
2. Make sure that measurement
C
does not exceed the value shown in the reference table
3. Make sure that you have fitted opening and closing mechanical gate stops
A
B
120 mi
n
C
27.
5
150 min
(°)
410 max
390
414
OUTward OPENING gates
For outward opening gate geometry and electrical connection differences, please refer to the full
Installation Manual.