P
age
32
- Manual
FA01412-EN
- 01/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
CZ input
Associate a function with the CZ input.
Confi guration>
Wired safety devices
CZ input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
C13 = Reopen while closing, with immediate stop once
the obstruction has been removed, even if the gate is not
in motion
r7 = Reopen while closing (sensitive edges with 8K2
resistor)
r8 = Reclose while opening (sensitive edges with 8K2
resistor)
r7 (two sensitive edges) = Reopen while closing (pair of
sensitive edges with 8K2 resistor)
r8 (two sensitive edges) = Reclose while opening (pair of
sensitive edges with 8K2 resistor)
CK input
Associate a function with the CK input.
Confi guration>
Wired safety devices
CK input
Deactivated (Default)
C1 = Reopen while closing (photocells)
C2 = Reclose while opening (photocells)
C3 = Partial stop Only with [Automatic close] activated.
C4 = Obstacle standby (photocells)
C7 = Reopen while closing (sensitive edges)
C8 = Reclose while opening (sensitive edges)
C13 = Reopen while closing, with immediate stop once
the obstruction has been removed, even if the gate is not
in motion
r7 = Reopen while closing (sensitive edges with 8K2
resistor)
r8 = Reclose while opening (sensitive edges with 8K2
resistor)
r7 (two sensitive edges) = Reopen while closing (pair of
sensitive edges with 8K2 resistor)
r8 (two sensitive edges) = Reclose while opening (pair of
sensitive edges with 8K2 resistor)