Time setting menu
[TIMING ADJ]
[Endstop]
[NC] / [NO]
Configure the endstops as normally closed or open contacts.
Warning!
Configure the endstops as normally closed contacts
[NC].
[Cmd 2-7]
[Open-Close] / [Op.-Stop-Cl]
Setting the 2-7 contact to step-by- step mode (open-close) or sequential (open-stop-close-stop).
[Cmd 2-3P]
[Pedestrian] / [Partial]
Configure the 2-3P contact to pedestrian opening (second gate leaf opens fully) or partial (second gate leaf opens partially) depending on the
time set
[Ped.opening]
in the
[TIMING ADJ]
menu.
[Lamp E3]
[Courtesy]
/
[Cycle]
Configure the light connected to E-E3:
- courtesy: outdoor light, which can be positioned freely, for better illumination in the parking/driveway area. It stays on for 5 minutes;
- cycle: outdoor light, which can be positioned freely, for better illumination in the parking/driveway area. It stays on from the moment the gate
leaf begins to open, until it is fully closed (including automatic closing time). Where the automatic closing function is not inserted, it stays on
only during gate movement.
[Output B1-B2]
[Monostable] / [Bistable]
Configure contact B1-B2 in monostable or bistable mode (switch).
[No. Motors]
[M1+M2] / [M2]
Setting the number of motors, either one or two, depending on the number of gate leaves installed in the system.
[CRP address]
[1]
⇨
[32]
For systems with more than one automation device using a CRP (Came Remote Protocol) connection system, set an address between 1 and
32 for each panel.
[CRP baudrate]
[1200] / [2400] / [4800] / [9600] / [19200] / [38400] / [57600] / [115200]
Set the communication speed used in the connection system and CRP (Came Remote Protocol).
[A.C.T.]
[0 s]
⇨
[300 s]
The waiting time before the gate closes automatically starts when the endstop point is reached during opening. The time can be set to between
0 s and 300 s. The gate is not closed automatically where the safety devices are triggered by an obstacle, after a total stop or where there is
no power.
[Pedestrian ACT]
[0 s]
⇨
[300 s]
Waiting time for the (M2) second gate leaf when in the open position. Once this time has elapsed, the gate closes automatically. The waiting
time interval can be between 0 s and 300 s.
[Cycle Time]
[10 s]
⇨
[150 s]
Gearmotor cycle time during opening or closing. The cycle time can be set to between 10 s and 150 s.
[Op. Delay M1]
[0
s]
⇨
[10 s]
M1 delayed opening with respect to M2 after each opening command. The waiting time interval can be between 0 s and 10 s.
[Cl. Delay M2]
[0
s]
⇨
[60 s]
M2 delayed closing with respect to M1 after each closing command. The waiting time interval can be between 0 s and 60 s.
[Prefl ashing T.]
[1
s]
⇨
[60 s]
After an opening or closing command is given, the flashing light connected to E1-E2 flashes for between 1 s and 60 s before the gate
begins to move.
[Lock time]
[1
s]
⇨
[15 s]
The time required for releasing the electrolock after each opening command. The time can be set to between 1 s and 5 s.
[Ram hit time]
[1
s]
⇨
[10 s]
The gearmotor thrust time when closing and opening after each command. The thrust time can be set to between
1 s and 10 s
[Ped. opening]
[5
s]
⇨
[60 s]
M2 opening time. The time can be set to between 5 s and 60 s.