CHECKING AND CHANGING OPERATING MODE
Press
SUN
briefly.
The LED corresponding to the brightness level comes on:
• if it goes off after 2 seconds, the sensor is set in mode 1;
• if the LED flashes 3 times after 2 seconds, the sensor is set in mode 2;
Hold down the
SUN
key for 10 seconds to switch from mode 1 to mode 2 and vice versa. The LED flashes 5 times to indicate that
the operation has been performed.
INSTALLATION
⚠
Installation must be carried out by qualified and experienced personnel in compliance with applicable regulations.
⚠
Internal use only
Preliminary checks and securing
Check that the point where the device is positioned is in an area protected from shocks, but still exposed to sunlight.
To improve adherence to the window, it is advisable to clean the glass thoroughly.
The double-sided adhesive film allows you to detach and reattach the sensor several times to the window leaving no glue residue
or streaks on the glass.
Putting into operation
In order to activate the sensor, perform:
P2 + P2
on a transmitter that has already been stored
P2
on the sensor.
Check: move the moving part halfway along its run by pressing
UP
on the sensor. The moving part moves to the upper limit
switch.
Summary of Contents for 001YE0169
Page 56: ...56 56 119T70575 119T70575 1 1 09 2016 CAME S p A 1 2 3 4 5 6 0 1 2 3 4 0 15 60 P2 0 0 1 2...
Page 57: ...57 57 119T70575 119T70575 1 1 09 2016 CAME S p A 2 1 2 3 2 10 1 2 5 P2 P2 P2...
Page 58: ...58 58 119T70575 119T70575 1 1 09 2016 CAME S p A 2 15...
Page 59: ...59 59 119T70575 119T70575 1 1 09 2016 CAME S p A CAME S p A 2014 53 CE...