Wall mounting 

With the allen wrench unscrew the blocking screws and remove the plate 

A

. Fix the given plugs and screw the entry panel 

B

 at the desired height.

Run the hose with the system conductors 

B

Extract the plastic terminal cover and wire the connections 

C

Once all the connections have been made, re-insert the terminal covers.

For the installation of the accessories refer to the chapter “Button module in-

stallation”. Perform the programming and adjustment operations of the entry 

panel as described to the chapter “Programming”. Install the front plate 

A

.

Recessed Installation (optional)

Install the recessed box at the desired height, but in advance, run the hose 

with the system conductors through one of the breaking points 

D

 

a

During installation of the recessed box it is possible to avoid any deformation 

by using the provided spacer 

D

 

. With the allen wrench unscrew the 

blocking screws and remove the entry panel plate 

A

. Introduce the cable 

connections in the special hole 

B

 and fix the entry panel on the frame 

E

extract the plastic terminal cover and wire the connections 

C

.

Once the connections have been made and re-insert the terminal covers. 

For the installation of the accessories refer to the chapter “Button module 

installation”.

Perform the programming and adjustment operations of the entry panel as 

described to the chapter “Programming”. Install the front plate 

A

.

Summary of Contents for 001DC011AC

Page 1: ...10 11 7 2 001DC011AC 001DC002AC 001DC011AC 001DC02EARY 001CS1PLCO INSTALLATION MANUAL 001CK0009 001CK0012 FR 001CK0013 FR EN English FA00959 EN AUDIO ENTRY KIT...

Page 2: ...allliabilityforanydamageasaresultofimpro per incorrect or unreasonable use eventuali danni derivanti da usi impropri erronei ed irragionevoli This product complies with the relevant directives in forc...

Page 3: ...time and without notice Technical features Type 001DC02EARY Power supply from BUS V DC 15 20 Consumption max mA 30 Consumption in stand by mA 0 5 Single LED consumption mA 1 Storage temperature C 25...

Page 4: ...ming the melody associated with a call from the floor To listen to the melodies in sequence press button e To select the melody and exit programming hang up the handset f To select the melody and cont...

Page 5: ...ate electric panel NOTE Proper ventilation is required if the power supplier is installed in a metal container Technical features Type 001DC002AC Power supply V AC 230 Max current demand A AC 0 2 Max...

Page 6: ...iver kit thedevicenotonlysuppliesthekitbutitalsoallowsyoutooperatethe gate Command 2 7 is executed by a clean contact relay Technical features Type 001DC011AC Minimum input voltage V AC 20 Maximum inp...

Page 7: ...ry panelasdescribedtothechapter Programming InstallthefrontplateA Recessed Installation optional Install the recessed box at the desired height but in advance run the hose with the system conductors t...

Page 8: ...of b Recessed box 001DC00PLCO03 c Recessed frame 001DC00PLACO02 d Technical features Tipo 001CS1PLCO Power supply V AC 16 18 Consumption mA 250 Consumption in stand by mA 100 Storage temperature C 25...

Page 9: ...thout notice Features J Terminal board a BOUT Riser Power supply 16 18VDC Terminal board Earth Door lock release button NA Solenoid lock 12V 1 A max PROG key and PROG LED Programming key and LED see P...

Page 10: ...ry h and continue repeating the same operations for the other extensions Entering Programming Mode Press the PROG a key for at least 3 seconds and then release it within 6 seconds as soon as the LED P...

Page 11: ...and remains lit At the end exit programming briefly press the PROG key g the PROG LED will turn off If no action is performed the procedure will end automatically after 30 minutes Programmingthecallk...

Page 12: ...02AC 2 001DC002AC 2 2 2 2 001DC002AC 2 001DC002AC 2 001DC011AC 4 4 10 11 7 2 001DC011AC CAME GATE 2 2 001DC002AC 2 001DC002AC 2 2 2 001DC011AC 4 4 10 11 7 2 001DC011AC CAME GATE 2 2 001DC002AC 2 001DC...

Page 13: ...M1 001DC02EARY M1 SW3 B 2 001DC02EARY M1 SW3 B 1 2 BOUT M1 M2 11 10 7 2 2 7 10 11 001DC02EARY SW3 M1 B 001CS1PLC0 001DC011AC CAME GATE 10 11 7 2 001DC011AC Page 13 Manual FA00959 EN vers 1 10 2017 Ca...

Page 14: ...011AC Page 14 Manual FA00959 EN vers 1 10 2017 Came S p A The contents of this manual may be changed at any time and without notice Distances VCM 1D VCM 2D UTP CAT 5 2x2 5mm2 La Lb Lc Ld 250 m 250 m L...

Page 15: ...Page 15 Manual FA00959 EN vers 1 10 2017 Came S p A The contents of this manual may be changed at any time and without notice...

Page 16: ...tiri Della Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Page 16 Manual FA00959 EN vers 1 10 2017 Came S p A The contents of this manual may be changed at any time a...

Reviews: