General Notes

• Read the instructions carefully before beginning the installation and carry 

out the actions as specified by the manufacturer.

• The installation, programming, commissioning and maintenance of the 

product must only be carried out by qualified technicians, properly trained 

in compliance with the regulations in force, including health and safety 

measures and the disposal of packaging.

• The installer must ensure that the information for the user, where there is 

any, is provided and delivered.

• Before carrying out any cleaning or maintenance operation, disconnect the 

devices from the power supply.

• The equipment must only be used for the purpose for which it was 

expressly designed.

• The manufacturer declines all liability for any damage as a result of impro-

per, incorrect or unreasonable use.

eventuali danni derivanti da usi impropri, erronei ed irragionevoli.

This product complies with the relevant directives in force.

Decommissioning and disposal. 

Dispose of the packaging and the device 

at the end of its life cycle responsibly, in compliance with the laws in force 

in the country where the product is used. The recyclable components are 

marked with a symbol and the material's ID marker.

The data and information shown in this manual are to be considered as 

subject to change at any time and without the need for any advance warning.

Measurements, unless otherwise indicated, are in millimetres.

001DC02EARY 

Installation 

Open the unit by pressing the lever on the back 

A

Remove the casing from the back of the unit.

Attach the back of the unit to a wall box using the screws provided 

B

B

. The box must be installed at a suitable height for the user. Do not 

over-tighten the screws.

Once connections have been completed, re-assemble the casing to the 

back of the unit 

C

.

Summary of Contents for 001DC011AC

Page 1: ...10 11 7 2 001DC011AC 001DC002AC 001DC011AC 001DC02EARY 001CS1PLCO INSTALLATION MANUAL 001CK0009 001CK0012 FR 001CK0013 FR EN English FA00959 EN AUDIO ENTRY KIT...

Page 2: ...allliabilityforanydamageasaresultofimpro per incorrect or unreasonable use eventuali danni derivanti da usi impropri erronei ed irragionevoli This product complies with the relevant directives in forc...

Page 3: ...time and without notice Technical features Type 001DC02EARY Power supply from BUS V DC 15 20 Consumption max mA 30 Consumption in stand by mA 0 5 Single LED consumption mA 1 Storage temperature C 25...

Page 4: ...ming the melody associated with a call from the floor To listen to the melodies in sequence press button e To select the melody and exit programming hang up the handset f To select the melody and cont...

Page 5: ...ate electric panel NOTE Proper ventilation is required if the power supplier is installed in a metal container Technical features Type 001DC002AC Power supply V AC 230 Max current demand A AC 0 2 Max...

Page 6: ...iver kit thedevicenotonlysuppliesthekitbutitalsoallowsyoutooperatethe gate Command 2 7 is executed by a clean contact relay Technical features Type 001DC011AC Minimum input voltage V AC 20 Maximum inp...

Page 7: ...ry panelasdescribedtothechapter Programming InstallthefrontplateA Recessed Installation optional Install the recessed box at the desired height but in advance run the hose with the system conductors t...

Page 8: ...of b Recessed box 001DC00PLCO03 c Recessed frame 001DC00PLACO02 d Technical features Tipo 001CS1PLCO Power supply V AC 16 18 Consumption mA 250 Consumption in stand by mA 100 Storage temperature C 25...

Page 9: ...thout notice Features J Terminal board a BOUT Riser Power supply 16 18VDC Terminal board Earth Door lock release button NA Solenoid lock 12V 1 A max PROG key and PROG LED Programming key and LED see P...

Page 10: ...ry h and continue repeating the same operations for the other extensions Entering Programming Mode Press the PROG a key for at least 3 seconds and then release it within 6 seconds as soon as the LED P...

Page 11: ...and remains lit At the end exit programming briefly press the PROG key g the PROG LED will turn off If no action is performed the procedure will end automatically after 30 minutes Programmingthecallk...

Page 12: ...02AC 2 001DC002AC 2 2 2 2 001DC002AC 2 001DC002AC 2 001DC011AC 4 4 10 11 7 2 001DC011AC CAME GATE 2 2 001DC002AC 2 001DC002AC 2 2 2 001DC011AC 4 4 10 11 7 2 001DC011AC CAME GATE 2 2 001DC002AC 2 001DC...

Page 13: ...M1 001DC02EARY M1 SW3 B 2 001DC02EARY M1 SW3 B 1 2 BOUT M1 M2 11 10 7 2 2 7 10 11 001DC02EARY SW3 M1 B 001CS1PLC0 001DC011AC CAME GATE 10 11 7 2 001DC011AC Page 13 Manual FA00959 EN vers 1 10 2017 Ca...

Page 14: ...011AC Page 14 Manual FA00959 EN vers 1 10 2017 Came S p A The contents of this manual may be changed at any time and without notice Distances VCM 1D VCM 2D UTP CAT 5 2x2 5mm2 La Lb Lc Ld 250 m 250 m L...

Page 15: ...Page 15 Manual FA00959 EN vers 1 10 2017 Came S p A The contents of this manual may be changed at any time and without notice...

Page 16: ...tiri Della Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Page 16 Manual FA00959 EN vers 1 10 2017 Came S p A The contents of this manual may be changed at any time a...

Reviews: