background image

CM-324 Series  

Active Infrared “Hands-Free” Switch

Installation Instructions

BY CAMDEN

Section 1: General Description

Sure-Wave™ hands-free” switch is an active infrared 

device designed for use with an automatic door operator 

or other access control product. 
Applications include low-energy doors, drive-up windows, 

health-care facilities, manufacturing, etc.
The assembly will fit in a variety of locations from a  

1 3/4” door frame to a 1-gang or 2-gang electrical box. 

Various size surface mounting boxes are also available 

from Camden. 

 

Three standard face plate widths are available:

CM-324:

 2 ¾” x 4 ½” polycarbonate or stainless steel, 

fits on single gang electrical boxes.

CM-324/ N:

 1 ¾” x 4 ½” polycarbonate or stainless 

steel, fits 1 ¾” door frames or our CM23D Jamb box.

CM-324/ W:

 4 ½” x 4 ½” polycarbonate or stainless steel, 

fits on single gang, double gang or 4 x 4 electrical boxes.
All faceplates may be ordered up with a plain face (/1), 

with the waving hand symbol (/2), or with the waving 

hand symbol and words: WAVE TO OPEN (/3).

Section 2: Installation 

Mounting

Sure-Wave™ may be mounted in door jambs, single or 

double gang electrical boxes, and 4 x 4 boxes.   

 

NOTE: The sealing gasket (included) is recommended for 

outdoor or wet locations. 

If using with Automatic doors install in 

accordance with ANSI A156.10 / A156.19. Select from one of 

the following three mounting subsections:

SINGLE GANG ELECTRICAL BOX: 

CM-324

1a – If using an in-wall box ensure the box is plumb and 

square, and flush with the wall surface. (See Diagram 1)
1b – If using a surface box, ensure it is secure & plumb.
2 – Bring your 4-conductor wire through the back or 

side of the enclosure and leave approximately 6” tail for 

wiring connection.
3 – Make the electrical connections to the device 

according to the wiring section (following).

4 – Using the dip switch located on the end of the unit, set 

the operating mode. (See Section 4) 
5 – Attach the unit to the enclosure using the two #6-32 

screws provided.
6 – Apply power and adjust range and time delay via the 

potentiometers on the front of the unit. (See Section 4 for 

adjustments)
7 – Attach the faceplate to the unit using the two black  

#6-32 x 3/8 machine screws or tamperproof screws.

Do not overtighten!!

Diagram 1 - Proper Box Installation

Rough Wall

Finish

Recessed

Box

Unaligned

Box

Wall

Wall Box

Flush

Smooth 

Wall Finish

Page 1 to 4

Summary of Contents for Sure-Wave CM-3242W

Page 1: ... mounted in door jambs single or double gang electrical boxes and 4 x 4 boxes NOTE The sealing gasket included is recommended for outdoor or wet locations If using with Automatic doors install in accordance with ANSI A156 10 A156 19 Select from one of the following three mounting subsections SINGLE GANG ELECTRICAL BOX CM 324 1a If using an in wall box ensure the box is plumb and square and flush w...

Page 2: ...ctions to the device according to the wiring section following 4 Using the dip switch located on the end of the unit set the operating mode See Section 4 5 Attach the unit to the enclosure or jamb using the two 6 32 screws provided 6 Apply power and adjust range and time delay via the potentiometers on the front of the unit See Section 4 for adjustments 7 Attach the faceplate to the unit using the...

Page 3: ...his will advise the person entering the swing side zone that the door will move 2 Instruct the owner on door system operation and how to test it This should be checked on a daily basis 3 Instruct the owner on what to do if the door or any of its components become damaged 4 Strongly recommend to the owner that the complete entry be inspected twice a year as part of the service agreement Section 5 T...

Page 4: ...gnetic Locks Key Switches Relays Timers Access Control CM 324 Active Infrared Hands Free Switch Installation Instructions CM 324 Rev1 Revised 03 18 2011 2 30 PM Part No 40 82B100 Diagram 2 Jamb Cutout Dimensions 1 0 2 3 3 75mm 26 660mm Diagram 5 Adjustable Range Settings 73mm 7 8 2 32mm 1 4 1 83mm 9 32 3 Drill Tap 6 32 2 holes Page 4 to 4 ...

Reviews: