background image

CM-324 Active Infrared “Hands-Free” Switch Installation Instructions

Switch 3 – LED On/LED Off

This switch disables the LED, 

should this feature be desired. 

Factory setting is 

ON

.

Once the Dip switches have been 

set, and the unit is installed in the 

frame or enclosure, apply power to 

the unit and observe operation.
Set both potentiometers to 

minimum setting initially (fully 

counter-clockwise).  

See Diagram 3 for location.
Adjust the range potentiometer 

by turning the pot in a clockwise 

manner, and passing your hand 

in front of the unit. Rotate the pot 

until the desired range is obtained. 

See Diagram 4 for patterns.
Next, adjust the time delay 

potentiometer by turning clockwise 

until the desired time delay is 

obtained. It is sometimes beneficial 

to leave this adjustment set to minimum and utilize the 

time delay on the door operator, if present. 

 

NOTE: Timer is non-functional in Toggle Mode.

Install the faceplate using the screws provided.

Do not overtighten!!

OPTIONAL

 – Apply the included Wheelchair logo to the 

frame or wall at desired location. See Diagram 5 on page 4.  

 

Do not apply directly to the faceplate!

If using this product with an Automatic Door, proceed to 

Section 4 for 

System Inspection Instructions

.

Section 4:  

System Inspection Instructions

After the Installation and operational check of the system:
1. Place warning label on the door (as per ANSI A156.10  

or A156.19 guidelines).  This will advise the person 

entering the swing side zone that the door will move.
2. Instruct the owner on door system operation and how  

to test it.  This should be checked on a daily basis.
3. Instruct the owner on what to do if the door or any of  

its components become damaged.
4. Strongly recommend to the owner that the complete 

entry be inspected twice a year as part of the service 

agreement.

Section 5: Technical Data

Section 6: Warranty

Camden Door Controls guarantees the Sure-Wave™ to  

be free from manufacturing defects for 3 years from date 

of sale.
If during the first 3 years the CM-324 fails to perform 

correctly, it may be returned to our factory where it will be 

repaired or replaced (at our discretion) without charge.  

Except as stated herein, Camden extends no warranties 

expressed or implied regarding function, performance or 

service.

Model

CM-324

Body Size

4” L x 1” W x 1 ½” Deep

Mounting

2 x #6-32 MS

Faceplates Sizes

Jamb, 1-gang, & 2-gang

Technology

Infra-Red with Coded Modulated Carrier

Security

Automatic Self-changing ID

Operating Modes

Pulse (sense) / Toggle

Operating Temp

-4 to +153 ºF (-20 to +85 ºC)

Operating Voltage

12-24 Volts, AC/DC ± 12%

Current Draw

50 - 60 mA.

Response Time

100 ms.

Activation Range: 

Minimum  

 

Maximum 

 

1” – 3”  

1” – 26”

Relay Output

Form C (SPDT)

Relay Contact Rating 5 amps @ 30 VDC
Output Type

Normal or Fail-Safe

Connections

11” 22 AWG Leads

Time Delay

1 to 5 Seconds

Electrical Life

100,000 Operations@ Rated Capacity
500,000 Operations@ ½ Rated Capacity

Door

Frame

25mm

1" 

CM-324/N3

Questions? Call us toll-free at 1-877-226-3369

Diagram 4  

Wheelchair  

Sticker  

Placement

Page 3 to 4

Summary of Contents for Sure-Wave CM-3242W

Page 1: ... mounted in door jambs single or double gang electrical boxes and 4 x 4 boxes NOTE The sealing gasket included is recommended for outdoor or wet locations If using with Automatic doors install in accordance with ANSI A156 10 A156 19 Select from one of the following three mounting subsections SINGLE GANG ELECTRICAL BOX CM 324 1a If using an in wall box ensure the box is plumb and square and flush w...

Page 2: ...ctions to the device according to the wiring section following 4 Using the dip switch located on the end of the unit set the operating mode See Section 4 5 Attach the unit to the enclosure or jamb using the two 6 32 screws provided 6 Apply power and adjust range and time delay via the potentiometers on the front of the unit See Section 4 for adjustments 7 Attach the faceplate to the unit using the...

Page 3: ...his will advise the person entering the swing side zone that the door will move 2 Instruct the owner on door system operation and how to test it This should be checked on a daily basis 3 Instruct the owner on what to do if the door or any of its components become damaged 4 Strongly recommend to the owner that the complete entry be inspected twice a year as part of the service agreement Section 5 T...

Page 4: ...gnetic Locks Key Switches Relays Timers Access Control CM 324 Active Infrared Hands Free Switch Installation Instructions CM 324 Rev1 Revised 03 18 2011 2 30 PM Part No 40 82B100 Diagram 2 Jamb Cutout Dimensions 1 0 2 3 3 75mm 26 660mm Diagram 5 Adjustable Range Settings 73mm 7 8 2 32mm 1 4 1 83mm 9 32 3 Drill Tap 6 32 2 holes Page 4 to 4 ...

Reviews: