background image

CV-500PPK-V.2

 Installation Instructions 

 

 

 
 
 

www.camdencontrols.com  
Toll Free: 1.877.226.3369 

File: CV-500PPK-V.2_NF-Man_Rev1.doc 
Revised: March 8, 2011 
Part No.: 40-82B131 

5502 Timberlea Blvd.,  
Mississauga, ON Canada L4W 2T7 

Wiring Diagram of Auxiliary Reader 

 
 

CV-500PPK-V.2 Aux. 

Reader 

 12 

Power 

supply 

 V 

Power 

supply 

1 1 

Data 

2 2 

Buzzer 

3 3 

Green 

LED 

M 4 

Common 

5 5 

Red 

LED 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

Figure

 

3

Auxiliary

 

Reader

 

Wiring

 

Diagram

It is recommended to use a separate 
Power supply for the auxiliary reader 

Summary of Contents for inVISION CV-500PPK-V.2

Page 1: ... or N C Jumper selection Relay 1 door relay RL1 Door Relay RL2 Alarm Relay Figure 1 Wiring Diagram Figure 2 Auxiliary Reader Connections This device comes with a varistor The varistor must be connected on the strike terminal electromagnet operated by the device If this product operates more than one strike each of them should have a varistor The varistor controls the overload produced by the strik...

Page 2: ...ter Code 000000 Relay time release 1 second Key in keypad 10 seconds Alarm OFF Audible Signals 1 beep long Validation of data in programming mode master code master card user card or time delay Or authorized access card or Pin code 2 beeps long Unauthorized access 4 beeps short Incorrect mode user number time entered data error 6 beeps long Entering in programming mode Or exiting from the programm...

Page 3: ...en door with PIN code and proximity card Green LED Present card and key in 4 digit PIN code Door opens MENU and Programming Procedure 1 2 3 4 5 6 7 8 Key in 6 digit Master Code Factory default code 000000 OR Present Master Badge 6 beep Red and Green LED Flashing Green LED Flashing Program Group of Card and PIN code automatically Program new Master code or Master badge Cancel Card and PIN code with...

Page 4: ...and enter the 4 digit Pin cod 1 beep is emitted and the LED flashes green and red Or enter the last 6 digit code decimal number of the first card from the sequential card group and press then enter the 4 digit Pin code 1 beep is emitted and the LED flashes green and red 9 Press to exit from the programming mode 6 beeps confirm the reader is in standby mode NOTE The card and pin code programming do...

Page 5: ...ed and the LED flashes green and red 7 Press to exit from the programming mode 6 beeps confirm the reader is in standby mode 3 Enter User Number 000 499 1 Beep Green LED flashing 1 Beep Green and RED LED flashing 1 Beep Red LED Program Door Release Time 1 Press 2 Enter the 6 digit master code for the first use the master code default is 000000 3 Press or present the Master Card 6 audible beeps are...

Page 6: ...Enter the 6 digit master code for the first use the master code default is 000000 3 Press or present the Master Card 6 audible beeps are emitted and the LED flashes green and red to confirm entry into programming mode 4 Press 6 then to enter into the alarm time delay menu 1 audible beep is emitted and the LED flashes green 5 To program the alarm time delay enter the 2 digit number from 01 to 99 Th...

Page 7: ...aster Card 6 audible beeps are emitted and the LED flashes green and red to confirm entry into programming mode 4 Press 8 then to enter inot the cancel group of card Pin code menu 1 audible beep is emitted and the LED flashes green 5 Enter the number of cards to cancel to a maximum of 99 Cards and Pin codes 6 Press 1 audible beep is emitted and the LED stops flashing 7 Present the first card from ...

Page 8: ...ll Free 1 877 226 3369 File CV 500PPK V 2_NF Man_Rev1 doc Revised March 8 2011 Part No 40 82B131 5502 Timberlea Blvd Mississauga ON Canada L4W 2T7 User Badges List make additional copies if required User Number Name User Number Name User Number Name User Number Name ...

Page 9: ... 8 2011 Part No 40 82B131 5502 Timberlea Blvd Mississauga ON Canada L4W 2T7 Wiring Diagram of Auxiliary Reader CV 500PPK V 2 Aux Reader 12 Power supply V Power supply 1 1 Data 2 2 Buzzer 3 3 Green LED M 4 Common 5 5 Red LED Figure 3 Auxiliary Reader Wiring Diagram It is recommended to use a separate Power supply for the auxiliary reader ...

Page 10: ...ile CV 500PPK V 2_NF Man_Rev1 doc Revised March 8 2011 Part No 40 82B131 5502 Timberlea Blvd Mississauga ON Canada L4W 2T7 7 8 23 2 mm 5 3 8 135 mm 4 3 4 120 mm 4 1 8 105 mm 13 16 20 5 mm 1 24 9 mm 5 8 15 mm 1 1 2 28 mm 2 3 8 61 mm 3 75 5 mm Figure 4 CV 500PPK V 2 Mounting Bracket Template ...

Page 11: ...dencontrols com Toll Free 1 877 226 3369 5502 Timberlea Blvd Mississauga ON Canada L4W 2T7 File CV 500PPK V 2_NF Man_Rev1 doc Revised March 8 2011 Part No 40 82B131 1 25 mm 1 4 6 mm 2 3 8 60 mm 3 3 4 96 mm 3 75 mm Figure 5 Auxiliary Reader Template ...

Reviews: