Technical Features
Input Voltage
12 V AC/DC
Output
2 relay outputs, N/O & N/C contact 3 A @ 125 V
Anti-Triggering Contact
500 mA 50 V AC/DC
Card
500 programmable cards or badges
PIN Code
500 programmable codes, 4-digit PIN code
Master Code
6-digit programmable code
Input 1
request-to-exit
Keyboard
12-digit keypad with built-in buzzer (audible signal)
Distance between the
second reader and the
CV-500PPK-V.2
Minimum 24 inches (60 cm)
Maximum 165 feet (50 meters)
(cable minimum requirement is 7 conductor 22 AWG)
Default Values
Master Code:
000000
Relay time release:
1 second
Key-in keypad:
10 seconds
Alarm:
OFF
Audible Signals
1 beep (long)
Validation of data in programming mode: master code, master card, user card or time delay.
Or
authorized access card or Pin code.
2 beeps (long)
Unauthorized access.
4 beeps (short)
Incorrect mode, user number, time entered, data error.
6 beeps (long)
Entering in programming mode.
Or
exiting from the programming mode.
Visual Signals
LED Color
Normal Mode
Programming Mode
Green
Door relay activated
Code/Badge position empty
Green flashing
Data computing validated
Red
Alarm relay activated
Code/Badge position busy
Red flashing
Proximity badge validated
Orange flashing
Stand-by
Data computing error
Request-to-exit
The request-to-exit push button PB1 operates relay RL1.
The LED turns green when the relay is activated.
Warning: