background image

CX-ED2079

‘Universal’ Electric Strike 

Installation Instructions

1. Description 

Camden CX-ED2079 low profile grade 2 ANSI strike for 

cylindrical locksets offers the very best strike quality and 

performance, with three stainless steel faceplates provided. 

The ‘Universal’ strike design delivers unparalleled application 

flexibility, with field selectable voltage, fail safe/fail secure 

operation and mechanical adjustment of the strike body.

1- 4 PIN power connector
1- ESP1B, ESP3B and    

  ESP4B faceplates
4- Wire nuts 
5- M5 x 12mm screws
2- #10 x 1  1/4” wood    

 screws

2- #10-32 x 1/2” screws
2- Mounting brackets
2- Spacers
1- Varistor

This Package Includes:

Page 1 of 3

2. Specifications

Voltage

12/24V AC/DC

Current Draw

300mA@12V DC 
150mA@24V DC

Static Strength

1,000 Lbs.

Dynamic Strength

50 Ft-Lbs.

Endurance

700,000 Cycles (Factory Tested) 
250,000 Cycles (UL Verified)

Mode

Field Selectable 
Fail Safe/Fail Secure

Mech. Adjustment

Strike Body/Faceplate

Operation

AC-Buzz  
DC-Silent

Duty

Continuous

Dimensions (Body)

3 3/8” H x 1 7/8” W x 1 7/32” D 
(86mm x 47mm x 31mm)

3. Dimensions

(32mm)

1 1/4”

(3mm)

1/8”

(12mm)

(86mm)

3 3/8”

(31mm)

1 7/32”

(31mm)

1 7/32”

(31mm)

1 7/32”

1/2”

(32mm)

(16mm)

1 1/4”

(42mm)

1 5/8”

(19mm)

3/4”

5/8”

(104mm)

4 1/8”

(123mm)

4 7/8”

(47mm)

1 7/8”

UL 1034
UL 294

UL 294 Performance Levels

  - Line Security = Level I
  - Attack Level = Level I 
  - Endurance Level = Level IV
  - Standby Power = Level I

Reviews: