CX-ED2079
‘Universal’ Electric Strike
Installation Instructions
1. Description
Camden CX-ED2079 low profile grade 2 ANSI strike for
cylindrical locksets offers the very best strike quality and
performance, with three stainless steel faceplates provided.
The ‘Universal’ strike design delivers unparalleled application
flexibility, with field selectable voltage, fail safe/fail secure
operation and mechanical adjustment of the strike body.
1- 4 PIN power connector
1- ESP1B, ESP3B and
ESP4B faceplates
4- Wire nuts
5- M5 x 12mm screws
2- #10 x 1 1/4” wood
screws
2- #10-32 x 1/2” screws
2- Mounting brackets
2- Spacers
1- Varistor
This Package Includes:
Page 1 of 3
2. Specifications
Voltage
12/24V AC/DC
Current Draw
300mA@12V DC
150mA@24V DC
Static Strength
1,000 Lbs.
Dynamic Strength
50 Ft-Lbs.
Endurance
700,000 Cycles (Factory Tested)
250,000 Cycles (UL Verified)
Mode
Field Selectable
Fail Safe/Fail Secure
Mech. Adjustment
Strike Body/Faceplate
Operation
AC-Buzz
DC-Silent
Duty
Continuous
Dimensions (Body)
3 3/8” H x 1 7/8” W x 1 7/32” D
(86mm x 47mm x 31mm)
3. Dimensions
(32mm)
1 1/4”
(3mm)
1/8”
(12mm)
(86mm)
3 3/8”
(31mm)
1 7/32”
(31mm)
1 7/32”
(31mm)
1 7/32”
1/2”
(32mm)
(16mm)
1 1/4”
(42mm)
1 5/8”
(19mm)
3/4”
5/8”
(104mm)
4 1/8”
(123mm)
4 7/8”
(47mm)
1 7/8”
UL 1034
UL 294
UL 294 Performance Levels
- Line Security = Level I
- Attack Level = Level I
- Endurance Level = Level IV
- Standby Power = Level I