GREASE GUN  
(OR TUBE APPLICATOR)

NEEDLE NOSE ADAPTER

"O" RING OR SEAL

SWIVEL RACE WAY

NYLON BUSHING OR 
BALL BEARING

VII. Care and Maintenance

WARNING ELECTRIC SHOCK HAZARD

MODULES: 

WARNING!

 Completely cool heater unit prior to cleaning or maintenance. 

WARNING!

 Do not submerge Hot or Cold module in water or spray water on it.

TO REMOVE ANY LINGERING SCENTS AND STAINS:

 

Use an odor removing soak or sanitizer to remove scents and stains that can occur from holding products with strong odors.
•  A diluted solution of 2-3 tablespoons of baking soda per gallon of hot tap water or 1 part lemon juice or vinegar to 4 parts hot water is also an effective 

way to remove lingering odors.

•  Rinse thoroughly with hot water and dry.

CLEANING INSTRUCTIONS

1.   Remove power from the unit prior to cleaning.
2.   DO NOT use pressurized cleaners or a water hose to clean this unit.
3.   Clean with mild detergent, hot water and a soft cloth. DO NOT use detergents or cleaners containing ammonia or bleach.
4.   Hand wash using a soft cloth or brush to clean all interior and exterior surfaces. DO NOT use steel wool or abrasive scrub pads or brushesd compartment.
5.   Clean the control display panel with a soft cloth without chemicals. Avoid scrubbing and damaging any safety or electrical labeling.
6.   Air dry or dry cart outside and inside with clean, dry, soft cloth. DO NOT power the unit unless everything has dried.

1.   Grease swivel raceway of caster using a lubricant such as Lubriplate No. 930-AA, Keystone #84EPXLT multi-purpose grease or the equivalent. Moving “O” Ring or 

seal with finger, apply grease using a grease gun with a needle nose adapter or a tube-type applicator such as “Sta-lube” Moly-graph Assembly Lube. These can 
be obtained at most auto parts stores.

2.   Use a light oil such as WD-40 on the nylon bushing at the hub. Check caster for any damage and test caster spin and swivel rotation before returning to service.

CASTER MAINTANANCE: 

To be performed every 6 months or after unit has been washed or steam cleaned: Wheel and swivel bearings last longer if lubricated regularly. Some lube 
applied to friction points on the wheel hub, washer and leg surfaces of straight roller bearing systems reduces drag and improves reliability. Normal conditions 
may warrant lubrication every six months, but once a month may be necessary in extreme applications, such as corrosive or exceptionally dirty environments. 
Cart washings may necessitate lubrication after each wash.

Summary of Contents for PRO CART ULTRA PCU800

Page 1: ...lated transporter versatile enough to hold hot or cold food If you have any further questions please contact your Cambro Sales Representative visit www cambro com or call our Customer Service Departme...

Page 2: ...CU2000 500Lbs 226 8Kg Empty weight 228Lbs 103 4Kg PCUL1000 250Lbs 113 4Kg Empty weight 154Lbs 69 9Kg Cleaning and user maintenance shall not be made by children without supervision Children shall not...

Page 3: ...es this clearance and fresh air at 82F 27 8 C or lower for best performance 9 The convenient magnet latches provide ease of access when loading or unloading the compartments 10 After loading all of yo...

Page 4: ...the C F button to decrease the desired temperature 3 Do not press any buttons for three 3 seconds and the temperature will be set How to set F or C units 1 Press the C F button to toggle between Cels...

Page 5: ...lled with hot water at starting temperature of 190 F 87 8 C held in compartment with door shut Water temperature dropped an average of only 3 F 1 61 C hr 1 Put the cart s brakes on if applicable and m...

Page 6: ...ompartment 5 Clean the control display panel with a soft cloth without chemicals Avoid scrubbing and damaging any safety or electrical labeling 6 Air dry or dry cart outside and inside with clean dry...

Page 7: ...aced in the center of the compartment Check fans for obstructions If none found replace unit Contact Cambro Customer Service Persistent odor inside the cabinet Initial start up of unit Food left in th...

Page 8: ...ENT PARTS Call Cambro Customer Service at 800 833 3003 or Call International 714 848 1555 Fax your order to 714 842 3430 or Call your local Cambro Representative or Distributor WARNING Components and...

Page 9: ...nd void including any responsibility for damage costs and legal actions resulting from use or installation of product s in any non commercial setting 7 Adjustments such as calibrations leveling tighte...

Reviews: