background image

If in any doubt about how to correctly operate or maintain your Cambrionix system  

product or OEM module, or if any part of this safety document is unclear or confusing,  

please do not use your product and contact Cambrionix before proceeding further.

Important Electrical and Safety Messages

Safety warning

Potential consequence if ignored

Do not modify the product in any way. 

Fire, electric shock or personal injury may occur.

Do not dismantle the product. 

Fire, electric shock or personal injury may occur.

Do not bend, compress or drill into any part of the product. 

Damage, electric shock or personal injury may occur.

Parts of Cambrionix products may become hot during  
operation. Do not obstruct air vents on the product or operate the 
product in an environment where the ambient temperature is outside 
the recommended operating temperature region. 

An increased internal temperature may cause a fire.

Cambrionix products are not reverse-polarity protected.  
The power connections MUST be connected correctly.  
If in doubt, please contact Cambrionix.

Damage to your Cambrionix product may occur. A fire or electric shock 
may result.

Do not short circuit the Power Supply Unit (PSU) supplied  
with your Cambrionix product.

Sparks, fire or electric shock may result.

Ensure dust does not collect around the power plug pins  
or power socket, or in or around the air vents to the extent  
it causes a reduction in air circulation. 

A fire may result if there is combustible material within the power 
socket or around the power plug, or if the internal  
temperature increases due to lack of air circulation.

Do not allow liquids to come into contact with the unit or  
power supply.

Fire, electric shock or personal injury may occur.

Keep the mains power socket (where the power cord is  
connected) unobstructed.

The power cord must be disconnected to cut off power to the product 
when an issue occurs. Note that the product may not be completely 
powered down by only using the power switch on the product.

Do not use a damaged power cord or plug, or a loose power socket.

An electric shock or fire may result.

Do not power multiple products from a single power socket. 

Overheated power sockets may cause a fire.

Do not touch the power plug with wet hands.

An electric shock may result.

Insert the power plug all the way into the socket so that it is not loose. 

An unsecured connection may cause a fire.

Connect the power plug to an earthed socket. 

Failure to connect use an earthed socket may result in an electric 
shock or injury.

Do not bend or pull the power cord with force. Be careful not  
to leave the power cord underneath a heavy object. 

Damage to the power cord may result in fire or electric shock.

Do not place the power cord near heat sources.

A fire or electric shock may result.

Only use the power cord provided (if applicable).

A fire or electric shock may result.

Only use the power supply provided with the product  
(if applicable). 

A fire or electric shock may result.

Do not disconnect the power cord while the product is being used.

The product may become damaged by electric shock.

Cambrionix OEM modules are susceptible to Electrostatic Discharge 
(ESD). OEM modules should be handled in an ESD safe area. 

Damage to your Cambrionix OEM module may occur.

There are sharp edges, corners and components.  
Suitable protective equipment must be worn during handling  
of Cambrionix OEM modules.

Personal injury may occur.

No power supply is shipped with a Cambrionix OEM module. Please 
contact your power supply manufacturer directly for safety related 
information.

Fire, electric shock or personal injury may occur. Please see the 
installation instructions for your Cambrionix product for correct wiring 
requirements.

When mounting a Cambrionix OEM module, all mounting holes should 
be used with appropriate spacers, screws and a torque level of 1.1Nm.

Damage or personal injury may occur.

This product can expose you to chemicals, including Nickel, which is known  
to the State of California to cause cancer or birth defects or other reproductive  
harm. For more information, go to www.p65Warnings.ca.gov 

Safety Guidelines and Precautions 

Please read and understand these  
guidelines prior to installation or use. 

The TS3-16 has ESD, over-voltage, over-current  

and over-temperature protection. However, to use 

the equipment safely you should follow all local  

regulations relating to the use of electrical  

equipment and note that: 

•  Failure to install and operate the equipment  

in accordance with all local and these safety  
guidelines may result in unit failure, electrical 
shock and personal injury.

•  The plug on the power cord is considered the 

“disconnect device” and consequently the mains 
outlet should be located near the TS3-16, easily 
accessible in case the power supply needs to be 
isolated from the mains power.

•  If there is a liquid spillage over a ventilation 

slot, external data/power connector or product 
aperture, remove power from the unit without 
contacting the liquid immediately.

ThunderSync3-16 

USER GUIDE

11

Summary of Contents for ThunderSync3-16

Page 1: ...ThunderSync3 16 USER GUIDE Charge Connect Manage ...

Page 2: ......

Page 3: ...5 4 1 Charging 5 4 2 Data Transfer 5 4 3 Scalability Syncing more than 16 devices 6 5 Manage Ports devices and updating your USB hub 7 5 1 LiveViewer and Updating your usb 7 5 2 Command Line Instructions CLI 8 5 3 Cambrionix API 9 6 Specifications 10 7 Certifications 10 8 Safety Guidelines and Precautions 11 Contents ThunderSync3 16 USER GUIDE 3 ...

Page 4: ... rate up to 2 4A per port The two Thunderbolt 3 rear ports provide 15 Watts each When a local host computer is attached the host can control the operation of each individual port using software provided by Cambrionix Device charging and synchronisation can be monitored through Cambrionix s LiveViewer App the Application Programming Interface API or Command Line Interface CLI Cambrionix s free moni...

Page 5: ...to a Thunderbolt 2 or Thunderbolt 3 compliant port of a local computer the TS3 16 defaults to Sync mode and charge currents are determined according to USB Implementers Forum USB IF SuperSpeed USB3 2 Gen 1 specifications If the attached device complies with USB IF Battery Charging specification BC1 2 and supports Charging Downstream Port CDP the TS3 16 can provide high speed charging at 1 5A If th...

Page 6: ... to synchronise more than 16 devices multiple TS3 16 can be daisy chained to allow up to 96 devices to be managed from a single host computer simultaneously In order to daisy chain multiple TS3 16 each TS3 16 needs to be connected to mains power individually and the first TS3 16 in the chain should be connected to the local computer through one of the Thunderbolt ports The next TS3 16 in the daisy...

Page 7: ...s battery capacity to receive and hold a charge Monitor Monitor speed of control and easily switch between charge and sync Numbers Check mobile devices IMEI OS version manufacturer and more Charge Information Duration How long the device has been attache End time Time the battery reaches a threshold full level Current Instantaneous charge current in mA Energy Present energy rate in Wh Hub health i...

Page 8: ...le i 1 0 Enable 1 or disable 0 profile i set_profiles p l Set profiles l associated with port p get_profiles p List profiles associated with port p sec arm disarm Set or reveal security mode host auto manual Show if USB host is present and set mode change id Show id string bd Board description logc s Report mA for each port every s seconds loge s Report state for all ports every s seconds and even...

Page 9: ...ownloaded from https www cambrionix com api and installed on the host machine Port information and control can be provided through the API Use Node JS or any other web technology to access information from the API using WebSockets Object Notation JSON Remote Procedure Calls RPC over TCP JSON RPC calls send a request to the API to Get port device or hub information or Set port functions such as mod...

Page 10: ...95 non condensing Dimensions approx 482 long x 270 wide x 42 high mm Approximate weight 3 7kg 7 Certifications Independently safety tested by the Underwriters Laboratory UL under file E346549 CE Tested and marked CB Certificate FCC Part 15 Tested and marked RoHS Compliant China CCC certification Japanese PSE certification pending Complies with the latest EN62368 safety requirements for ITE Housed ...

Page 11: ...r plug to an earthed socket Failure to connect use an earthed socket may result in an electric shock or injury Do not bend or pull the power cord with force Be careful not to leave the power cord underneath a heavy object Damage to the power cord may result in fire or electric shock Do not place the power cord near heat sources A fire or electric shock may result Only use the power cord provided i...

Page 12: ...Cambrionix Ltd The Maurice Wilkes Building Cowley Road Cambridge CB4 0DS United Kingdom T 44 0 1223 755 520 E enquiries cambrionix com W www cambrionix com TS3 16_0221 ...