background image

ModIT-MAX

Página 16 de 41

Para conectar varios concentradores en cadena, cada concentrador debe estar conectado a la
red eléctricaindividualmente, luego el primer concentrador de la cadena debe conectarse a la
computadora local a través de uno de los puertos Thunderbolt™. El siguiente concentrador en la
conexión en cadena se conecta mediante uno de sus puertos Thunderbolt™ al puerto
Thunderbolt™ restante del primer concentrador. Es posible añadir un tercer, cuarto y quinto
hubs de la misma manera, conectando el puerto Thunderbolt™ disponible delhub anterior a uno
de los puertos Thunderbolt™ del siguiente dispositivo de la conexión en cadena. Using this
approach, a maximum of six hubs can be linked together, allowing 96 devices to be synced
from a single host computer.

Summary of Contents for ModIT-MAX

Page 1: ...Manual de usuario traducido ModIT MAX 2023 01 2022 Cambrionix Ltd Todos los derechos reservados ES...

Page 2: ...4 4 Conexi n al host 9 4 5 Charging 10 4 6 Cables 10 4 7 Llaves 10 4 8 Registration 10 4 9 Help and Support 10 5 Using your ModIT MAX 12 5 0 1 LED Configuration 12 5 1 Using without connecting to hos...

Page 3: ...de salida 27 6 3 Valores de riel de bandera de error 27 6 4 Especificaciones f sicas 27 6 5 Informaci n empaquetada 28 6 6 Consumibles y realizaci n de pedidos 28 7 Troubleshooting 31 7 1 Initial tro...

Page 4: ...rionix Device charging and synchronisation can be monitored through Cambrionix s LiveViewer Application the Application Programming Interface API or Command Line Interface CLI Cambrionix s free monito...

Page 5: ...se and safety during operation This user manual cannot cover all possible applications If you would like additional information or if problems arise that are not sufficiently addressed in this manual...

Page 6: ...ead operating instructions Mandatory regulation 3 4 Product modification Cambrionix products are designed and manufactured to meet the requirements of UK and International safety regulations Modificat...

Page 7: ...I N An electric shock or personal injury may occur l Do not use a damaged power cord or plug or a loose power socket l Do not touch the power plug with wet hands l Do not allow liquids to come into co...

Page 8: ...to your Cambrionix product may occur l Operate the product only in an environment where the ambient temperature is inside the operating temperature range l Operate the product only in an environment...

Page 9: ...e correct before opening This is to avoid retesting and repackaging any items that are not required When opening the packaging use a suitable method to open the box i e do not use a knife This is to e...

Page 10: ...eguir us ndolo 4 4 Conexi n al host Once the power is connected connect the ModIT MAX to your host system using a Thunderbolt 3 cable El uso de un cable de host incorrecto puede dar lugar a que el hub...

Page 11: ...nnect to our hubs 4 7 Llaves Your ModIT MAX comes with a set of keys which can be used to manually close and open the locking mechanisms on all of the slots at once Con ello se anula cualquier otra fu...

Page 12: ...ModIT MAX P gina 11 de 41 Providing serial and Purchase order numbers can help identify the product in question faster and speed up the process...

Page 13: ...ling the device Red Port is in charge mode and is charging Green Port is in charge mode and the device has reached the charged threshold Blue Port is in Sync mode and has a host connection LED Off No...

Page 14: ...n una interfaz para forzar la alimentaci n sistemas compatibles hay una interfaz para forzar la alimentaci n del controlador Thunderbolt Si se admite este comando solicitar al daemon que compatible es...

Page 15: ...string joined with n like cbrxapi cbrx_connection_set handle settings settings_unlock nsettings_rese t nsettings_set sync_chrg 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 nsettings_set alt_sync_ chrg 0 0 0 0 0 0...

Page 16: ...icamente Si este no es el caso o si se utiliza una plataforma Mac o Linux el controlador puede descargarse de www ftdichip com Los controladores VCP son obligatorios Para computadoras Linux o Mac se d...

Page 17: ...concentrador en la conexi n en cadena se conecta mediante uno de sus puertos Thunderbolt al puerto Thunderbolt restante del primer concentrador Es posible a adir un tercer cuarto y quinto hubs de la m...

Page 18: ...disconnect briefly whilst the profiling process takes place Once the profiling has taken place and a charging profile is selected the device will then draw a charge rate which will be defined by the...

Page 19: ...pple 5 4 4 Firmware The firmware can be kept up to date using our LiveViewer software As part of delivering an easy user experience our LiveViewer application is now a set and forget solution The Live...

Page 20: ...e Firmware versions and hardware We advise not to change the firmware version on any new products you receive as this may cause compatibility issues and stop your ModIT MAX from functioning PRECAUCI N...

Page 21: ...ound a bug that we have a fix for the Alpha and Beta releases may already have addressed these and implemented fixes 5 5 1 Installing Software Cambrionix has two pieces of software that can be used to...

Page 22: ...rt is in Charge mode the charge profile current energy rate charge duration and end time are displayed In addition to individual port information and control LiveViewer shows the hub rail voltages tim...

Page 23: ...ation and control can be provided through the API Calls are sent as a request to the API to Get port device or Hub information or Set port functions such as mode A library of sample code can be obtain...

Page 24: ...nto Add or remove programs finding the software you wish to remove selecting it and pressing uninstall macOS To remove the software from a macOS system locate the application in the Finder drag the ap...

Page 25: ...ll the installed packages that match those letters at the beginning of their names 5 5 6 Command Line Instructions CLI Command Line Instructions can be used to control and monitor the functions of the...

Page 26: ...rama amarilla l Desenchufe el cable del m dulo l Una vez retirado el cable original conecte el nuevo cable y repita los pasos a la inversa 5 6 2 Ajuste del tope trasero Puede ajustar el tope trasero a...

Page 27: ...Limpie el producto con un pa o limpio seco y suave No utilice detergentes que contengan alcohol disolvente ni agentes tensoactivos No roc e agua ni detergente directamente sobre el producto l Humedez...

Page 28: ...de salida 5 0 V 5 Corriente de salida m x por puerto 2 4 A Potencia de salida m x por puerto 12 W Potencia de salida total 200 W 6 3 Valores de riel de bandera de error Riel de cinco voltios m x 5 58...

Page 29: ...T5A 240V Cables 16 x USB 3 2 tipo A If you require any spare parts such as the power cables or Thunderbolt 3 cable these can be ordered by quoting the product part number and the spare part number ava...

Page 30: ...ModIT MAX P gina 29 de 41...

Page 31: ...ModIT MAX P gina 30 de 41...

Page 32: ...ewer if this is not already downloaded then go onto our website and download both the API and LiveViewer www cambrionix com software 2 Once in LiveViewer on the left hand side of the screen select the...

Page 33: ...ngs either by going through the advanced settings and turning Sync charge off or through the API and disabling it via code For example the instructions would be below using the command line settings_u...

Page 34: ...ositivo en la conexi n inicial Esto tambi n podr a deberse a una cantidad insuficiente de puntos finales disponibles en el controlador USB en el sistema host Esta limitaci n dentro del controlador USB...

Page 35: ...or E mark type C cables may not work on the daisy chain when connecting the expansion port to another PDysnc 4 We recommend to use passive type C cables and not to use cables fitted with e markers see...

Page 36: ...rionix cambrionix log cfg 7 7 Software troubleshooting Some users have noted that the API can cause a high level of CPU usage This can sometimes be linked to the API recorder service If you are findin...

Page 37: ...the Council of the European Union on the waste electrical and electronic equipment WEEE and in jurisdictions adopting that Directive is marked as being put on the market after August 12 2005 and shou...

Page 38: ...f the delivery note detailing this 9 2 What happens after I have requested a Return l If you have not purchased the Product s direct from Cambrionix please contact the vendor the item was originally p...

Page 39: ...sitos de seguridad de la norma EN 60950 para equipos inform ticos l Probado y marcado seg n la Parte 15 de la FCC l Alojado en una envolvente a prueba de incendios de la especificaci n UL94 VO l Cumpl...

Page 40: ...trademarks service marks and other protected names and or symbols contained in this manual and related documents are the property of their respective holders Mac and macOS are trademarks of Apple Inc...

Page 41: ...MOD IT 90079186690001 007918669 0001 90079186690001 MOD IT 90079186690002 007918669 0002 90079186690002 MOD IT 90079186690003 007918669 0003 90079186690003 MOD IT 90079186690004 007918669 0004 9007918...

Page 42: ...2a6ebe915fe9 202012310 202012310 MOD IT MM 195758 MOD IT MM 329441 001 MOD IT MM 29 735 479 MOD IT 6077256 6077256 6077256 MOD IT STACK 6077257 6077257 6077257 MOD IT STACK 081a4b9c69eb 202012312 2020...

Page 43: ...ad Cambridge CB4 0DS Reino Unido 44 0 1223 755 520 enquiries cambrionix com www cambrionix com Cambrionix Ltd es una empresa registrada en Inglaterra y Gales con el n mero de empresa 06210854 2023 01...