page 19
Qt Conference Room Edition Installation and Operations Guide
Surface mount on a suitable 4-gang electrical box (3-gang using EU/UK hardware)
4-gang electrical box (pre-installed or retrofitted) – after the cables have been run to the box, use four
supplied screws to attach the wall plate adapter. (In the case of EU 3-gang boxes, use M3 or M3.5 screws
as needed – these are not included.) Then attach the system back to the wall adapter.
Note:
The wall plate adaptor is ABS plastic and may be painted to match wall color. Use a standard
spray primer (Krylon) before painting.
INSTALLATION
Wall plate adapter
4-gang NEMA wall box
or low voltage clip
(not included)
Wall hole
8x wall plate
adapter screws
Controller
Case back
panel
4x control module
back panel screws
Wall hole
Wall plate adapter
3-gang EU/UK wall box
(not included)
6 x screw
(not included)
Controller
Case back panel
4 x #6
self-threading
screw