background image

Chapter 4:  Cable Installation and Grounding 

Available Cable Options 

 

phn-3972 004v000 

Page 4-10 

Available Cable Options 

Fiber Optic Cables 

Table 11  Fiber Optic cables part numbers 

Marketing P/N 

Description 

N000082L139A 

PTP 820 Optical cable, SM, 30m 

N000082L140A 

PTP 820 Optical cable, SM, 50m 

N000082L141A 

PTP 820 Optical cable, SM, 80m 

N000082L142A 

PTP 820 Optical cable, SM, 100m 

N000082L143A 

PTP 820 Optical cable, SM, 150m 

N000082L146A 

PTP 820 Fiber 1+1 Splitter, SM 

N000082L147A 

PTP 820 Fiber Adapter 

 

DC Cable and Connector 

Table 12  DC cable and connector 

Part Number 

Description 

N000082L019A 

PTP 820 Outdoor_DC_cbl_2x18AWG_drum 

N000082L065A 

PTP 820 DC Connnector 

 

Ethernet Cable and Specifications 

Table 13  DC cable and connector 

Part Number 

Description 

N000082L015A 

CAT5E_Outdoor_305m_drum 

 

This cable is suitable for: 

o

 

Fast Ethernet 

o

 

Gigabit Ethernet 

o

 

PoE 

The following figure shows the cable design. The numbers in the figure refer to the items listed 
beneath the figure. 

Summary of Contents for PTP 820S Assured

Page 1: ...INSTALLATION GUIDE PTP 820S and PTP 820S Assured System Release 10 0 ...

Page 2: ...Accordingly any copyrighted material of Cambium its licensors or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Cambium Furthermore the purchase of Cambium products shall not be deemed to grant either directly ...

Page 3: ...es 6 In non EU countries 6 Chapter 1 Product description 1 1 Important Notes 1 2 Safety Precautions Declared Material 1 3 General Equipment Precautions 1 3 Précautions générales relatives à l équipement 1 4 Allgemeine Vorsichtsmaßnahmen für die Anlage 1 4 Chapter 2 Pre Installation Instructions 2 1 Packing 2 2 Transportation and Storage 2 2 Unpacking 2 2 Inspection 2 2 Chapter 3 Product Hardware D...

Page 4: ...lands 4 14 General Installation Procedure 4 15 Connecting an Optical Fiber Cable and SFP 4 20 Connecting a DC Power Cable 4 24 Connecting the Ethernet Cable 4 27 Preparing the Ethernet Cable and Plug in Field 4 27 Preparing the Ethernet Cable Already Assembled 4 30 Connection of Ethernet Cable to PTP 820S 4 31 Management Connection for 1 1 HSB Configurations 4 33 Preparing a Protection Signaling C...

Page 5: ...7 5 Required Tools 7 5 Procedure 7 5 2 0 Dual Polarization Remote Mount 7 8 List of Items 7 8 Required Tools 7 8 Common Installation Procedures 7 9 1 1HSB 2 0 Single Polarization Direct Mount 7 14 List of Items 7 14 Required Tools 7 14 Procedure 7 14 1 1HSB 2 0 Single Polarization Remote Mount 7 17 List of Items 7 17 Required Tools 7 17 Procedure 7 18 Mediation Device Losses 7 21 Chapter 8 Accepta...

Page 6: ...re 9 Glands 4 14 Figure 10 Removing glands 4 15 Figure 11 Protection Signaling Cable Pinouts 4 33 Figure 12 PoE Injector cable connection 5 2 Figure 13 PoE Injector Wall Mount Installation 5 4 Figure 14 Mount PTP 820S DC Pole Mount to Pole 6 3 Figure 15 Horizontal Vertical Pole 7 3 Figure 16 Twist orientation 7 3 Figure 17 2 0 Dual Polarization Direct Mount 7 5 Figure 18 2 0 Dual Polarization Remo...

Page 7: ...able Electrical Requirements 4 11 Table 16 Outdoor DC Cable Electrical Requirements 4 12 Table 17 Glands kit 4 14 Table 18 Materials for preparing Ethernet Data Cables 4 27 Table 19 Required items for Wall Mount PoE Injector 5 4 Table 20 Required item for 19 Rack Installation PoE Injector 5 6 Table 21 Required items PoE Injector ETSI Rack 5 8 Table 22 Required items for 1 1 Direct Mount configurat...

Page 8: ...ion and Connection Chapter 6 Generic Installation Procedures and Notes Chapter 7 PTP 820S Detailed Configurations Description Chapter 8 Acceptance and Commisioning Procedures Contacting Cambium Networks Support website https support cambiumnetworks com Main website http www cambiumnetworks com Sales enquiries solutions cambiumnetworks com Support enquiries https support cambiumnetworks com Repair ...

Page 9: ...re of the customer or anyone acting on the customer s behalf to abide by the instructions system parameters or recommendations made in this document Cross references References to external publications are shown in italics Other cross references emphasized in blue text in electronic versions are active links to the references This document is divided into numbered chapters that are divided into se...

Page 10: ...for one 1 year from date of shipment from Cambium Networks or a Cambium distributor Cambium Networks warrants that hardware will conform to the relevant published specifications and will be free from material defects in material and workmanship under normal use and service Cambium shall within this time at its own option either repair or replace the defective product within thirty 30 days of recei...

Page 11: ...zed security practices Security aspects to be considered are protecting the confidentiality integrity and availability of information and assets Assets include the ability to communicate information about the nature of the communications and information about the parties involved In certain instances Cambium makes specific recommendations regarding security practices however the implementation of ...

Page 12: ...he following format Warning Warning text and consequence for not following the instructions in the warning Cautions Cautions precede instructions and are used when there is a possibility of damage to systems software or individual items of equipment within a system However this damage presents no danger to personnel A caution has the following format Caution Caution text and consequence for not fo...

Page 13: ...m equipment in EU countries Disposal of Cambium equipment European Union EU Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE Do not dispose of Cambium equipment in landfill sites For disposal instructions refer to http www cambiumnetworks com support Disposal of surplus packaging Do not dispose of surplus packaging in landfill sites In the EU it is the individual recipient s res...

Page 14: ...iverse deployment scenarios PTP 820S supports cutting edge capacity boosting techniques such as QPSK to 2048 QAM and Header De Duplication to offer a high capacity solution for every network topology and every site configuration Its green compact all outdoor configuration makes PTP 820S ideal for any location This chapter includes Important Notes Safety Precautions Declared Material ...

Page 15: ...es or modifications of equipment not expressly approved by the manufacturer could void the user s authority to operate the equipment and the warranty for such equipment PTP 820S is intended for installation in a restricted access location PTP 820S must be installed and permanently connected to protective earth by qualified service personnel in accordance with applicable national electrical codes ...

Page 16: ...n those specified herein may result in hazardous radiation exposure Caution When working with a PTP 820S note the following risk of electric shock and energy hazard Disconnecting one power supply disconnects only one power supply module To isolate the unit completely disconnect all power supplies Caution Machine noise information order 3 GPSGV the highest sound pressure level amounts to 70 dB A or...

Page 17: ...nnan utrustning och samtidigt är kopplad till kabel TV nät kan i vissa fall medfőra risk főr brand Főr att undvika detta skall vid anslutning av utrustningen till kabel TV nät galvanisk isolator finnas mellan utrustningen och kabel TV nätet Précautions générales relatives à l équipement Caution L utilisation de commandes ou de réglages ou l exécution de procédures autres que celles spécifiées dans...

Page 18: ... 820S das folgende Stromschlag und Gefahrenrisiko Durch Abtrennen einer Stromquelle wird nur ein Caution Stromversorgungsmodul abgetrennt Um die Einheit vollständig zu isolieren trennen Sie alle Stromversorgungen ab Maschinenlärminformations Verordnung 3 GPSGV der höchste Schalldruckpegel beträgt 70 dB A oder weniger gemäß EN ISO 7779 ...

Page 19: ...72 004v000 Page 2 1 Chapter 2 Pre Installation Instructions This chapter describes the Pre Installation instructions for PTP 820S This chapter includes Packing Transportation and Storage Unpacking Inspection ...

Page 20: ...s required the packed equipment must be stored in a dry and cool environment and out of direct sunlight in accordance with ETS 300 019 1 1 Class 1 2 Unpacking The equipment is packed in sealed plastic bags and moisture absorbing bags are inserted Any separate sensitive product such as printed boards are packed in anti static handling bags The equipment is further packed in special designed cases M...

Page 21: ...ion This chapter describes the PTP 820S components interfaces and mediation devices This chapter includes PTP 820S Hardware Overview PoE Injector System Components Adaptors and Installation Kits Antenna Connection Power Specifications Environmental Specifications ...

Page 22: ...e Overview phn 3972 004v000 Page 3 2 PTP 820S Hardware Overview PTP 820S features an all outdoor architecture consisting of a single unit directly mounted on the antenna Figure 1 PTP 820S Rear View Left and Front View Right Figure 2 Cable Gland Construction ...

Page 23: ...10 100 1000Base T Supports PoE o Optical 1000Base X optional Data Port 2 for GbE traffic o Electric10 100 1000Base T o Optical 1000Base X optional Data Port 3 for GbE traffic o Electric 10 100 1000Base T o Optical 1000Base X optional Power interface 48VDC Management Port 10 100Base T 1 RF Interface Standard interface per frequency band RSL interface BNC connector Grounding screw ...

Page 24: ...an be mounted on a wall pole or indoor rack Each PoE Injector kit includes the following items PoE injector 2 caps Figure 4 PoE Injector The following table listst the Cambium approved PoE Injector Table 1 PoE Injector part number Part Number Description N000082L022A Includes two DC power ports with power input ranges of 18 60 V each ...

Page 25: ...n PoE Injector phn 3972 004v000 Page 3 5 PoE Injector Interfaces Power Over Ethernet PoE Port GbE Data Port supporting 10 100 1000Base T DC Power Port 1 18 60 V or 40 60 V DC Power Port 2 18 60 V Grounding screw Figure 5 PoE Injector Ports ...

Page 26: ...w the main components used in the PTP 820S installation procedures Note In general the PTP 820S utilizes the exact same mediation devices as the RFU C unless stated otherwise Figure 6 System components PTP 820S Coupler OMT Remote Pole Mount Remote Dual Pole Remote Mount 4 0 4 4 Extender Remote Mount for 4 0 Twist PoE Injector ...

Page 27: ...2L084A N180082L050A RFU C Twist KIT N060082L148A N070082L304A N110082L093A N130082L061A N150082L083A N180082L049A RFU C OMT KIT N060082L146A N070082L302A N110082L091A N130082L059A N150082L081A N180082L047A Table 3 Adaptors and installation kits for 23 to 38 GHz Description 23GHz 26GHz 28 31GHz 32GHz 38GHz RFU C Coupler KIT N230082L037A N260082L030A N280082L040A N320082L023A N380082L047A RFU C Symm...

Page 28: ... Adaptor Remote Mount KIT N060082L003A N070082L001A N110082L001A N130082L001A RFU C WG Kit N060082L156A N070082L004A N110082L105A N130082L070A N150082L092A Table 5 Remote Mount 18 to 38 GHz Remote Mount 18 GHz 23 GHz 26 GHz 28 GHz 32 GHz 38 GHz RFU C Remote Mount KIT N000082L121A N000082L121A N000082L121A N000082L121A N000082L121A N000082L121A PTP 820C DC Remote Mount KIT N000082L120A N000082L120A...

Page 29: ...0082L311A N110082L104A N130082L069A N150082L091A N180082L057A Table 7 Antenna Circ Adapters for OMT for 12 to 38 GHz Antenna Circ Adapters for OMT 23GHz 26GHz 28GHz 32GHz 38GHz CommScope N230082L039A N260082L032A N280082L042A N320082L025A N380082L049A Radio Waves N230082L046A N260082L038A N280082L046A NA N380082L054A CNT N230082L047A N260082L039A N280082L047A N320082L030A N380082L055A Table 8 PoE ...

Page 30: ...Side Remote Flange Des Flex WG Side A Flange Des Flex WG Side B Flange Des Antenna Remote Flange Des Band Range GHz 6 L U GHz 5 8 7 1 31 8 mm WR137 UDR70 PDR70 PDR70 UDR70 7 8 GHz 7 1 8 5 26 mm WR112 UBR84 PBR84 PBR84 UBR84 10 11 GHz 10 0 11 7 18 mm WR90 UBR100 PBR100 PBR100 UBR100 13 GHz 12 7 13 3 15 mm WR75 UBR120 PBR120 PBR120 UBR120 15 GHz 14 5 15 4 13 5 mm WR62 UBR140 PBR140 PBR140 UBR140 18 ...

Page 31: ...nly be installed by service personnel The unit must have a permanent connection to protective grounding Data port 2 Data port 3 the Management port and the TNC connector do not provide protection from over voltages on telecommunication networks for host equipment users The RSL interface connector is intended for technician use only Disconnect device circuit breaker in the building installation Sha...

Page 32: ...19 1 4 Class 4 1 Temperature range for continuous operating temperature with high reliability 33 C 27 F to 55 C 131 F Temperature range for exceptional temperatures tested successfully with limited margins 45 C 49 F to 60 C 140 F Humidity 5 RH to 100 RH IEC529 IP66 Storage ETSI EN 300 019 1 1 Class 1 2 Transportation ETSI EN 300 019 1 2 Class 2 3 ...

Page 33: ...ounding procedure This chapter includes Minimum and Maximum Cable Diameter Cable Grounding Surge Protection Securing the Cables Available Cable Options Special Instructions for use of Glands Connecting an Optical Fiber Cable and SFP Connecting an Optical Fiber Cable and SFP Connecting a DC Power Cable Connecting the Ethernet Cable ...

Page 34: ...004v000 Page 4 2 Minimum and Maximum Cable Diameter To fit the gland the outer cable diameter should be between 6 10 mm This applies to all glands on both the PTP 820S unit and the PoE Injector To fit the grounding clamp the outer diameter of CAT5E Ethernet Cables must be between 6 7 1mm ...

Page 35: ...le on page 4 24 no grounding is required For Ethernet cables the shielded Ethernetcable SF UTP construction must be grounded to the antenna tower at the top next to the PTP 820 unit and the indoor cabinet and every 50m using the Ethernet Cable Grounding Kit N000082L017A Figure 7 Grounding cable To Connect the Grounding kit Table 10 Cable Grounding Kit Marketing P N Description CAT5E gnd Kit High S...

Page 36: ...nd Grounding Cable Grounding phn 3972 004v000 Page 4 4 2 Place the cable in the middle of the grounding bracket 3 Close the grounding bracket around the cable 4 Tighten the two screws to secure the grounding bracket around the cable ...

Page 37: ...ounding bar or directly to the tower 6 Tighten the grounding lug Grounding the PTP 820S Unit Required Tools Metric offset wrench key wrench 3 Metric wrench 10mm Procedure 1 On the front of each PTP 820S unit loosen the nut plain washer and serrated washer from the GND stud using the metric offset hexagon key and the wrench ...

Page 38: ...erify that the result is 0 2 ohms Note The unit s grounding screw terminal is permanently connected to protective earth in a building installation in accordance with applicable national code and regulations by a service person A 2 pole circuit breaker a branch circuit protector suitably certified in accordance with applicable national code and regulations rated maximum 20A shall be installed for f...

Page 39: ...om 40 VDC to 60 VDC Warning Availability of a UPS Uninterrupted Power Source battery backup and emergency power generator is desirable The power supply must have grounding points on the AC and DC sides Caution The user power supply GND must be connected to the positive pole in the PTP 820S power supply Any other connection may cause damage to the system Note For the warranty to be honored you must...

Page 40: ...omplies with surge immunity standard IEC 61000 4 5 level 4 provided the Ethernet cables were prepared according to the instructions in Preparing the Ethernet Cable and Plug in Field on page 4 27 In areas in which severe lighting conditions are likely to occur it is strongly recommended to add additional protection by placing lightning protectors on all electrical Ethernet cables near the connectio...

Page 41: ...972 004v000 Page 4 9 Securing the Cables All cables must be secured at every meter on site using a suitable Outdoor Cable Tie Take special care to apply the proper amount of force in order to avoid damage to the cable This is especially important for optical SFP cables ...

Page 42: ...43A PTP 820 Optical cable SM 150m N000082L146A PTP 820 Fiber 1 1 Splitter SM N000082L147A PTP 820 Fiber Adapter DC Cable and Connector Table 12 DC cable and connector Part Number Description N000082L019A PTP 820 Outdoor_DC_cbl_2x18AWG_drum N000082L065A PTP 820 DC Connnector Ethernet Cable and Specifications Table 13 DC cable and connector Part Number Description N000082L015A CAT5E_Outdoor_305m_dru...

Page 43: ... 4 Tinned copper braid 5 Jacket Table 14 Ethernet cable Color Code Pair Wire A Wire B 1 WHITE blue BLUE 2 WHITE orange ORANGE 3 WHITE green GREEN 4 WHITE brown BROWN Outdoor Ethernet Cable Specifications Table 15 Ethernet Cable Electrical Requirements Electrical Requirements Cable type CAT 5e SFUTP 4 pairs according to ANSI TIA EIA 568 B 2 Wire gauge 24 AWG Stranding Solid ...

Page 44: ...T5E gnd kit Operating and Storage temperature range 40 C 85 C Flammability rating According to UL 1581 VW1 IEC 60332 1 RoHS According to Directive 2002 95 EC Outdoor DC Cable Specifications Table 16 Outdoor DC Cable Electrical Requirements Electrical Requirements Cable type 2 tinned copper wires Wire gauge 18 AWG for 100m installations 12 AWG for 100m installations Stranding stranded Voltage ratin...

Page 45: ...vailable Cable Options phn 3972 004v000 Page 4 13 Jacket PVC double UV resistant Outer diameter 7 10 mm Operating Storage temperature range 40 C 85 C Flammability rating According to UL 1581 VW1 IEC 60332 1 RoHS According to Directive 2002 95 EC ...

Page 46: ...P 820S unit is supplied with two glands If additional glands are required they must be ordered separately in kits of five glands each Table 17 Glands kit Part Number Description N000082L014A PTP 820 Glands_x5_KIT In order to remove the plastic plugs for the unit you can use the flange of supplied glands to disconnect them See the figures below Figure 9 Glands ...

Page 47: ... 10 Removing glands General Installation Procedure This procedure applies to all cable types and explains how to install the cables using long glands The gland is supplied assembled 1 Before inserting a cable you must disassemble the gland cap and gland rubber from the gland body 2 Slide the gland cap into the cable ...

Page 48: ...gland without disturbing the cable 5 Optionally after securing the cable into the body of the gland close the other side of the gland with an M28 gland cap The gland cap protects the cable and connector from damage when elevating the cable and gland to the radio unit 6 The M28 gland cap has hook on top After attaching the gland cap to the gland connect a rope to the hook and use this to lift the g...

Page 49: ...ort 9 Screw the gland into the radio unit until there is full contact between the gland and the radio unit Note Before tightening the gland make sure the gland is aligned with the taped hole in the unit Tightening the gland at an angle can ruin the thread on the gland and prevent proper sealing of the interface Tighten the gland gently and make sure there is no resistance If there is resistance st...

Page 50: ... the gland Verify that the gland thread is not damaged and tighten the gland again Caution Pay attention that the gland rubber is properly located and not damaged during the tightening of the gland cap If the gland thread is damaged do not use it 11 Tighten the rear portion of the gland onto the main part of the gland and make sure that the main part of the gland does not have an additional swivel...

Page 51: ...Chapter 4 Cable Installation and Grounding Special Instructions for use of Glands phn 3972 004v000 Page 4 19 ...

Page 52: ...ting an Optical Fiber Cable and SFP To connect an optical fiber cable and the SFP transceiver 1 Use a pre assembled cable 2 Split the connector into two separate LC Connectors one for each fiber 3 Remove the gland cap and rubber from the gland body 4 Slide the gland cap into the cable 5 Slide the rubber into the cable ...

Page 53: ...the cable to a radio unit on a tower this step is crucial to prevent the cable from slipping from the gland which could damage the connector 8 Connect the fibers to the SFP transceiver Listen for the click to ensure that it is fully inserted 9 Remove the tie wrap securing the cable to the gland Note A new tie wrap must be used to secure the cable to the gland at the end of the procedure as describ...

Page 54: ...and ensure it is aligned with the taped hole in the unit Tightening the gland at an angle can ruin the thread on the gland and prevent proper sealing of the interface Tighten the gland gently and make sure there is no resistance If there is resistance stop immediately thread out the gland and verify that the gland threads are not damaged Then tighten the gland again Caution If the gland thread is ...

Page 55: ...Chapter 4 Cable Installation and Grounding Connecting an Optical Fiber Cable and SFP phn 3972 004v000 Page 4 23 ...

Page 56: ...r Cable To connect a DC power cable 1 Strip off 45 mm from the cable jacket 2 Expose 10 mm at the edge of each of the two wires 3 Insert the power cable into the gland 4 Insert the power cable wires into the power connector 5 Insert the power cable wires into the power connector Match to the 0V wire and to the 48V wire ...

Page 57: ...Grounding Connecting a DC Power Cable phn 3972 004v000 Page 4 25 6 Tighten the two top screws 7 Plug the power cable with connector into the PTP 820S power connector 8 Tighten the two front screws 9 Screw the gland into the radio unit ...

Page 58: ...n with the cover Tighten the gland gently and make sure there is no resistance If there is resistance stop immediately and verify that the gland is not being inserted at an angle Tightening the gland at an angle can ruin the thread on the gland and prevent proper sealing of the interface 10 Tighten the gland cap 11 Secure the cable to the gland with a tie wrap ...

Page 59: ...rnet Cable to PTP 820S Note To ensure proper grounding and connectivity it is recommended to use pre assembled Ethernet cables Preparing the Ethernet Cable and Plug in Field Note To ensure proper grounding the RJ 45 plug must be shielded with a crimping tail Table 18 Materials for preparing Ethernet Data Cables Marketing P N Description CAT5E_SFUTP_Outdoor_50m CABLE RJ45 TO RJ45 STR 50M CAT 5E ETH...

Page 60: ...nd wrap the drain wire around the foil Do not remove any insulation from the conductors 5 Align the colored wires Note Cord colors should be matched to the same pins on both ends of the cable 6 Trim all wires to the same length About 12 mm on the left should be exposed from the inner sheath 7 Separate the wires and place the twisted braid between the separated wires 8 Insert the wires into the RJ4...

Page 61: ...re proper grounding it is essential that the twisted braid be firmly connected to the RJ45 plug 11 Crimp the RJ45 plug with the crimp tool Make sure the twisted braid is crimped firmly to the RJ45 plug 12 Verify that the wires ended up the correct order and that the wires extend to the front of the RJ45 plug and make good contact with the metal contacts in the RJ45 plug 13 Push back the CAT5E plug...

Page 62: ...equivalent to make sure the cable complies with ANSI TIA EIA 568 B 2 Make sure to verify both connectivity and grounding continuity at both ends of the cable Preparing the Ethernet Cable Already Assembled To prepare the Ethernet cable already assembled 1 Release the gland cap and the gland rubber slightly 2 Insert the CAT5E cable into the gland cap and into the rubber gland 3 Insert the CAT5E cabl...

Page 63: ...ect the CAT5E cable to the PTP 820S 3 Screw the gland into the radio unit Caution Before tightening the gland make sure the gland is even with the cover Tighten the gland gently and make sure there is no resistance If there is resistance stop immediately and verify that the gland is not being inserted at an angle Tightening the gland at an angle can ruin the thread on the gland and prevent proper ...

Page 64: ...Chapter 4 Cable Installation and Grounding Connecting the Ethernet Cable phn 3972 004v000 Page 4 32 4 Tighten the gland cap 5 Secure the cable to the gland using a tie wrap ...

Page 65: ...explain how to prepare and connect these cables Preparing a Protection Signaling Cable The Protection signaling cables require the following pinouts Figure 11 Protection Signaling Cable Pinouts CAT5E cable 2 4 6 8 RJ 45 connector male Port1 TX Port1 TX Port1 RX Port1 RX Port2 TX Port2 TX Port2 RX Port2 RX 1 3 5 7 2 4 6 8 RJ 45 connector male Port1 TX Port1 TX Port1 RX Port1 RX Port2 TX Port2 TX Po...

Page 66: ...nagement port Mng A standard CAT5E cable should be connected to the splitter s management port in order to utilize out of band external management Note Even for systems that use in band management initial configuration of an HSB protection configuration must be performed manually using out of band management Protection signaling port Prot A Protection signaling cross cable as described above shoul...

Page 67: ...tion This chapter describes the PTP 820S PoE Injector installation and connection procedure This chapter includes PoE Injector Cable Connection PoE Injector Grounding PoE Injector Wall Mount Installation PoE Injector 19 Rack Installation PoE Injector ETSI Rack Installation ...

Page 68: ...ecting a DC Power Cable on page4 24 The total length of the cable between the PTP 820S port and the Switch Router the device is connected to must not exceed 100m 328ft This length includes the connection between the PTP 820S and the PoE Injector X1 X2 100m 328ft in the figure below Note The length of the cable connecting the customer equipment to the PoE injector should not be longer than 10m acco...

Page 69: ... To ground the PoE Injector On the right side of each PoE Injector loosen the screw plain washer and serrated washer Place the cable lug supplied with the PoE injector kit between the plain and serrated washer Tighten the screw Perform a resistance test between the 2 lugs of the GND cable Verify that the result is 0 2 ohms ...

Page 70: ... Metric offset wrench key wrench set Hammer Drilling Machine Procedure 1 Mount and tighten the PoE Injector to a wall using two M6 bolts and anchors The M6 bolts and anchors must be purchased separately Note Use anchor stainless steel with flanged hexagonal nut M6X70 2 Drill two 6mm diameter holes with 100mm distance between the center of the holes 3 Insert the anchors with the bolts 4 Place the w...

Page 71: ...Chapter 5 PoE Injector Installation and Connection PoE Injector Wall Mount Installation phn 3972 004v000 Page 5 5 ...

Page 72: ...d item for 19 Rack Installation PoE Injector Item Description Quantity Remarks 1 PoE Injector 1 2 PoE Injector 19 Rack Mount KIT 1 Required Tools Philips Screwdriver Procedure To mount the PoE Injector on a rack 1 Mount the PoE Injector to a 19 rack using a 19 rack adaptor 2 Mount the PoE Injector on the 19 adaptor through the wall mounting holes using M6 screws and washers ...

Page 73: ...Chapter 5 PoE Injector Installation and Connection PoE Injector 19 Rack Installation phn 3972 004v000 Page 5 7 3 Mount the 19 rack adaptor to a 19 rack using four M6 screws and cage nuts ...

Page 74: ...equired items PoE Injector ETSI Rack Item Description Quantity Remarks 1 PoE Injector 1 2 PoE Injector ETSI Rack Mount KIT 1 Required Tools Philips Screwdriver Procedure To mount the PoE Injector to an ETSI rack 1 Mount the PoE Injector to an ETSI rack using a 19 rack adaptor and ETSI adapting ears 2 Connect the ETSI adapting ears to a 19 rack adaptor using four M6 screws ...

Page 75: ...on phn 3972 004v000 Page 5 9 3 Mount the PoE Injector on the adaptor through the wall mounting holes using M6 screws and washers 4 Mount the 19 rack adaptor with the ETSI ears on the ETSI rack using four M6 screws and cage nuts Note For this type of installation a 2RU space is required ...

Page 76: ...4v000 Page 6 1 Chapter 6 Generic Installation Procedures and Notes This chapter describes the generic nstallation procedure and notes for PTP 820S This chapter includes Torque Requirements Pole Mount Installation ...

Page 77: ...20 Nm torque for radio antenna radio mediation device and mediation device antenna connections In order to avoid misalignment screws should be tightened progressively When fastening a waveguide to the radio or mediation device use the following torque according to frequency and screw type 6 GHz M5 10 32 3 5 Nm 7 8 15 GHz M4 8 32 2 5 Nm 18 42 GHz M3 4 40 1Nm ...

Page 78: ...DC Pole Mount Procedure List of Items Table 22 Required items for 1 1 Direct Mount configuration Item Description Quantity Remarks 1 PTP 820S DC Pole Mount KIT 1 Required Tools Metric offset wrench key wrench set Procedure 1 Mount and tighten the PTP 820S DC pole mount to a pole with a diameter of 114 mm using the four washers and screws supplied with the PTP 820S DC pole mount kit Figure 14 Mount...

Page 79: ... This chapter describes the PTP 820S detailed configuration description This chapter includes 1 0 Direct Mount Installation 2 0 Dual Polarization Direct Mount 2 0 Dual Polarization Remote Mount 1 1HSB 2 0 Single Polarization Direct Mount 1 1HSB 2 0 Single Polarization Remote Mount ...

Page 80: ...or 1 1 Direct Mount configuration Item Description Quantity Remarks 1 PTP 820S Radio 1 Required Tools The following tools are required for the PTP 820S installation Metric offset hexagon key wrench 6 Phillips 2 screwdriver Procedure 1 To install the PTP 820S in a direct mount 1 0 configuration Caution Do not remove the transparent pressure window located on the antenna interface ...

Page 81: ...ion 1 0 Direct Mount Installation phn 3972 004v000 Page 7 3 Note If necessary change the antenna polarization by rotating the unit in accordance with the relevant antenna installation guide Figure 15 Horizontal Vertical Pole Figure 16 Twist orientation ...

Page 82: ... below the letter V on the pins and fasten the two screws Note For 6 GHz separate irises are used for vertical and horizontal polarization The vertical iris comes assembled with the PTP 820S The horizontal iris MA 1840 X PTP 820S Twist 6Ghz Horizontal is included in the PTP 820S 2 Mount the PTP 820S on the antenna using the four M8 captive screws and washers that are supplied and tighten the screw...

Page 83: ...DP configuration List of Items Table 24 Required items for 2 0 Dual polarization direct mount configuration Item Description Quantity Remarks 1 PTP 820S Radio 2 2 RFU C OMT KIT 1 Required Tools Metric offset hexagon key set Metric wrench key set Procedure 1 Prior to the installation follow the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transitio...

Page 84: ...Mount phn 3972 004v000 Page 7 6 2 Connect the RFU C OMT Kit to the antenna and secure it with four screws Verify the existence of the O ring 3 Mount the two O Rings supplied with the RFU C OMT kit on the OMT body Make sure the mounting direction is correct as shown in the section view ...

Page 85: ...ve screws and washers supplied through the radio and OMT holder and tighten the screws Make sure the polarization mounting direction is correct 5 Tilt the entire assembly as described in the dual polarization link alignment procedure to achieve maximum XPD Cross Polar Differentiation After link alignment tighten the four M8 screws left open in step 2 above ...

Page 86: ...2 0 DP configuration Figure 18 2 0 Dual Polarization Remote Mount List of Items Table 25 Required items for 2 0 Dual polarization direct mount configuration Item Description Quantity Remarks 1 PTP 820S Radio 1 2 RFU C OMT KIT 1 3 FLEXIBLE WG KIT 2 4 RFU C Pole Mount KIT 1 5 RFU C Remote Mount Adaptor KIT 1 From 6 13GHz Required Tools Metric offset hexagon key set Metric wrench key set Phillips 1 2...

Page 87: ...urer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2 Connect the RFU C OMT Kit to the antenna and secure it with four screws Verify the existence of the O ring 3 Mount the two O Rings supplied with the RFU C OMT kit on the OMT body Make sure the mounting direction is correct as shown in the section ...

Page 88: ...r 6Ghz UDR70 i Mount the O Ring supplied with the OMT kit ii Mount OMT Adaptor 1 on the OMT and tighten using four M4 screws and washers supplied with the OMT adaptor kit iii Mount OMT Adaptor 2 on OMT Adaptor 1 and tighten using four M4 screws and washers supplied with the OMT adaptor kit iv Mount the flexible waveguide as usual 2 For 7 11 GHz UBR84 and UBR100 i Mount the O Ring supplied with the...

Page 89: ...ling gasket on the OMT and tighten using the four M4 screws and washers supplied with the OMT Adaptor kit iii Mount the flexible waveguide without its gasket only for the OMT side 3 For 13 GHz UBR120 to 38 GHz UG383 U connect the flexible waveguide and its gasket supplied with the Flexible WG Kit directly to the OMT port 4 Loosen the 2 screws and remove the twist ...

Page 90: ...to RFU C Pole Mount Bracket using the four captive screws and washers supplied assembled in the PTP 820S 6 Connect the Flexible Waveguide and sealing O Ring supplied with the Flexible Waveguide Imperial kit Tighten the four metric screws supplied with the RFU C Adaptor kit Note Remote Configuration Frequencies 13 38 GHz do not require adaptors ...

Page 91: ...Chapter 7 PTP 820S Detailed Configurations Description 2 0 Dual Polarization Remote Mount phn 3972 004v000 Page 7 13 Frequencies 6 13 GHz require remote mount adaptors ...

Page 92: ... Required items for 1 1HSB 2 0 Single Polarization Direct Mount configuration Item Description Quantity Remarks 1 PTP 820S Radio 2 2 RFU C Coupler Splitter KIT 1 For 1 1HSB configuration a coupler must be used 3 RFU C Twist KIT 1 Required Tools The following tools are required for the installation Metric offset hexagon key wrench 6 Phillips 2 screwdriver Metric offset hexagon key wrench 2 5 and 3 ...

Page 93: ... must be mounted in the twist grooves For 6 GHz frequency a gasket is used instead of an O Ring The gasket must be mounted between the twist and the RFU C Coupler kit 1 Mount the twist to the coupler using the O Ring and four screws supplied in the Twist kit and tighten the screws Caution Make sure the polarization mounting direction of the twist to the coupler is according to the antenna polariza...

Page 94: ...r radio on the antenna using the four M8 screws and washers supplied with the RFU C Coupler kit and tighten the screws 3 Mount the two O Rings supplied with the RFU C Coupler kit as shown in the following figure 4 Mount the PTP 820S to the body of the coupler using the four M8 captive screws and washers that are supplied and tighten the screws ...

Page 95: ...rization Remote Mount HSB ACCP List of Items Table 27 Required items for 1 1HSB 2 0 Single Polarization Remote Mount configuration Item Description Quantity Remarks 1 PTP 820S Radio 1 2 RFU C Pole Mount KIT 1 3 RFU C Coupler Splitter KIT 1 For 1 1HSB configuration a coupler should be used FLEXIBLE WG Metric KIT 1 Required Tools The following tools are required for the installation Metric offset he...

Page 96: ... attached to a coupler while the coupler is connected to the antenna via flexible WG To install the PTP 820S in a remote mount 1 1 configuration 1 Mount the RFU C coupler to the RFU C pole mount bracket using the four M8 screws and washers supplied with the RFU C Coupler kit and tighten the screws 2 Mount the two O Rings supplied with the Coupler kit according to the Coupler kit instructions ...

Page 97: ...e supplied assembled in the PTP 820S and tighten the screws 4 Place the O Ring in the flexible waveguide flange groove 5 Mount the flexible waveguide on the coupler and tighten the screws and washers Note For 6 GHz only4 screws should be used as shown in the following figures 6 Place the O Ring in the other end of the flexible waveguide flange groove 7 Mount the flexible waveguide on the antenna a...

Page 98: ...Chapter 7 PTP 820S Detailed Configurations Description 1 1HSB 2 0 Single Polarization Remote Mount phn 3972 004v000 Page 7 20 ...

Page 99: ...Remote Mount antenna Added on remote mount configurati ons 0 5 0 5 1 2 1 5 1 5 1 0 Direct Mount Integrated antenna 0 2 0 2 0 4 0 5 0 5 OMT Direct Mount Integrated antenna 0 3 0 3 0 3 0 5 0 5 Splitter Direct Mount Integrated antenna 3 3 3 4 3 4 3 4 3 5 Note The antenna interface is always the PTP 820S interface If other antennas are to be used an adaptor with a 0 1 dB loss must be considered The nu...

Page 100: ...cedure is to verify correct installation and operation of the installed link and the interoperability with customer end equipment Cambium s Acceptance and Commissioning procedure includes the following stages Site Acceptance Procedure Commissioning of Radio Link The Site Acceptance Procedure is a checklist that summarizes the installation requirements of the site at which the products were install...

Page 101: ...model Site name Site code Radio link code Site address 2 ANTENNA MOUNTING Antenna mount type Mount is of sufficient height to clear local obstructions OK Mount is safely positioned to not cause a safety hazard OK Mount is secure and perpendicular OK Mount is grounded as per site specifications OK All steelwork is Galvanized or Stainless Steel as appropriate OK 3 ANTENNA Antenna type model and size...

Page 102: ...ysical damage and connectors are sealed OK All flexible waveguide bolts are secured using washers and lock washers as appropriate OK Flexible waveguide is secured to the pole OK 6 CAT5 Fiber Optic CABLE Overall cable length Cable type CAT5 connectors assembled properly on the cable OK Cable connected securely to ODU and IDU OK Cable connector is covered by gland and secure by cable tie at the ODU ...

Page 103: ...vals 0 5 m recommended OK Flexible WG has no sharp bends kinks or crushed areas All bends are per manufacturer specifications OK Flexible WG point of entry to building shelter is weather proof OK Flexible WG ends are properly labeled OK 8 DC POWER SUPPLY Two Inputs Measured DC voltage input to the IDU 40 5 to 60 VDC Power Supply maximum current Power Supply is properly grounded OK DC power backup ...

Page 104: ...Procedures Site Acceptance Procedure phn 3972 004v000 Page 8 26 SITE ACCEPTANCE CHECKLIST continued 10 REMARKS NOTES 11 GENERAL INFORMATION Site accepted by Name Title Company Signature Date Site approved by Name Title Company Signature Date ...

Page 105: ...n above o Antenna sway braces are fitted and installed correctly where applicable Typically for an antenna of 1 2 m or larger an extra sway brace is fitted to the mounting frame of the antenna This sway brace should not be mounted to the same pole as the antenna but should be installed directly back to the tower or an alternative point o Antenna Water Drain Plugs are fitted and removed where appro...

Page 106: ...hecklist Notes phn 3972 004v000 Page 8 28 Antenna labels for link identity and bearing ODU labels for link identity frequency and polarization Cat5 Fiber cable labels for link identity close to the ODU switch and either end of any joint Switch labels for link identity ...

Page 107: ... Interfaces Test Connect Ethernet Packet Analyzer to the GbE port Use physical loop at remote end or connect second analyzer Run Packet Loss test for at least one hour load rate as per Cambium s specifications for the chosen MRMC Connect Ethernet Packet Analyzer to the FE port Use physical loop at remote end or connect second analyzer Run Packet Loss test for at least one hour load rate as per Cam...

Page 108: ... link and that you are able to perform changes to the link configuration frequency channel Tx power system name time date etc Verify that correct parameters are reported when performing the above Verify that there are no active alarms on the link If the management station is located at a remote site Network Operation Center verify that the management station can manage the link and receive traps ...

Page 109: ...ommissioning Log is important for tracking your installations and to provide essential data for Cambium Networks Upon completing the Commissioning Log send the log to Cambium Networks support center at https support cambiumnetworks com PTP 820 LINK COMMISSIONING LOG 1 GENERAL INFORMATION Customer Radio model Configuration Radio link code Site 1 name add Site 2 name add 2 ODU RFU Site 1 Site 2 ODU ...

Page 110: ...SL Main dBm RSL Diversity dBm Deviation from exp RSL 4 dB 5 COMMISSIONING TESTS Site 1 Site 2 Line loopback Pass Pass ODU loopback Pass Pass Radio BER Pass Pass FE test Pass Pass GbE test Pass Pass 6 MANAGEMENT CONFIGURATION Site 1 Site 2 Eth IP Address Eth IP mask Default router In band VLAN 7 REMARKS NOTES 8 INSTALLATION INFORMATION Installed by Name Company Date Signature Commissioned by Name C...