Chapter 3: Grounding the PTP 820C HP Unit
Environmental Specifications
phn-4794_002v000
Page 3-2
2 Place the cable lug (supplied with the PTP 820C HP grounding kit) in place on the screw.
3 Secure the cable lug.
4 The second side of the GND cable should be connected to the main ground bar or terminal ground
bar of the site.
5 Perform a resistance test between the 2 lugs of the GND cable. Verify that the result is 0-2 ohms.
Notes
The unit’s earthing screw terminal shall be permanently connected to protective earth in a
building installation in accordance with applicable national code and regulations by a
service person.
Any outdoor antenna cable shield shall be permanently connected to protective earth in a
building installation.