background image

Chapter 7:  PTP 820C HP Detailed Configurations Description 

2 x 2+0 Dual Polarization Remote Mount 

 

 

Page 7-37 

 

For 7, 8, 10, and 11 GHz, there is a single adaptor: 

Figure 38  Mounting the Single Adaptor for 7, 8, 10, and 11 GHz 

 

 

 

4  Mount and tighten the O-ring and the flexible waveguide to the adapter ports using the screws 

supplied with the flexible waveguide kit. 

Important: Verify that the O-rings are correctly mounted between the OMT ports and each flexible 
waveguide. 
 

Summary of Contents for PTP 820C HP

Page 1: ...phn 4794_002v000 Rev B INSTALLATION GUIDE PTP 820C HP ...

Page 2: ...material Accordingly any copyrighted material of Cambium its licensors or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Cambium Furthermore the purchase of Cambium products shall not be deemed to grant either ...

Page 3: ...iption 1 1 Important Notes 1 2 Safety Precautions Declared Material 1 3 Public and Occupational Boundary Distances Under Article 3 1 a of the RE Directive 1 3 General Equipment Precautions 1 3 Précautions générales relatives à l équipement 1 4 Allgemeine Vorsichtsmaßnahmen für die Anlage 1 5 Pre Installation Instructions 1 6 Packing 1 7 Transportation and Storage 1 7 Unpacking 1 7 Inspection 1 7 C...

Page 4: ... 5 Power Source 4 8 Surge Protection 4 9 Available Cable Options 4 10 Fiber Optic Cables Single Mode 4 10 Fiber Optic Cables Multi Mode 4 10 DC Cable and Connector 4 10 Cables for MIMO Connections 4 11 Ethernet Cable and Specifications 4 11 Outdoor Ethernet Cable Specifications 4 13 Outdoor DC Cable Specifications 4 13 Securing the Cables 4 15 Special Instructions for use of Glands 4 16 General In...

Page 5: ...emote Mount 7 5 List of Items 7 6 Required Tools 7 6 Procedure 7 6 2 0 Single Polarization Direct Mount 7 12 List of Items 7 12 Required Tools 7 12 Procedure 7 12 2 2 HSB Double Polarization Direct Mount 7 15 List of Items 7 15 Required Tools 7 15 Procedure 7 15 2 2 HSB Double Polarization Remote Mount 7 19 List of Items 7 19 Required Tools 7 19 Procedure 7 20 2 2 HSB Single Polarization Direct Mo...

Page 6: ...lator Direct Mount 7 62 4 0 Dual Polarization Remote Mount 7 63 List of Items 7 63 Required Tools 7 63 Procedure 7 63 4 0 with Dual Circulator Remote Mount 7 68 Dual Circulator Multi Carrier Kit Installation 7 69 List of Items 7 69 Required Tools 7 69 Procedure 7 69 AFR 1 0 Hub Site 7 75 List of Items 7 75 Required Tools 7 75 Procedure 7 76 Chapter 8 Installation Instructions for Configurations wi...

Page 7: ...ization 8 110 8 0 Dual Polarization 8 113 1 1 HSB 8 116 2 2 HSB Single Polarization 8 119 2 2 HSB Dual Polarization 8 125 Chapter 9 Installing PTP 820C HP on Third Party Antenna Adaptors 9 128 Special Note on Converting ValuLine 3 Antennas 9 1 Chapter 10 Acceptance and Commissioning Procedures 10 2 Site Acceptance Procedure 10 1 Site Acceptance Checklist Notes 10 5 Radio Link Commissioning Procedu...

Page 8: ...Signaling Cable Pinouts 4 34 Figure 22 4x4 MIMO or HSB Protection Configuration with External Management 4 35 Figure 23 Transparent Pressure Windows 5 2 Figure 24 PTP 820C HP Installation Radio and Diplexers Unit Pre Assembled 6 4 Figure 25 PTP 820C HP Installation Attaching the Diplexers Unit Before the Radio Unit 6 5 Figure 26 Fitting the Diplexer Unit to the Radio Unit Radio Side 6 7 Figure 27 ...

Page 9: ... 8 85 Figure 47 Right Rail Configuration 8 85 Figure 48 Left and Right Rail Configurations Together 8 85 Figure 49 Attaching the Radio to the OCU 8 86 Figure 50 Order of Fastening Screws 8 86 Figure 51 Angling the OCU Rail Underneath the Nose of the Branching Pole Profile 8 87 Figure 52 Final Position of OCU Radio Locked into Branching Pole Profile 8 87 Figure 53 Securing the OCU Radio Unit to the...

Page 10: ...anges 2 25 Table 8 Power connection options part numbers 2 26 Table 9 Grounding Cable 3 1 Table 10 Cable Grounding Kit 4 5 Table 11 Fiber Optic Cables Single Mode part numbers 4 10 Table 12 Fiber Optic Cables Multi Mode 4 10 Table 13 DC cable and connector 4 10 Table 14 Cables for MIMO Connections 4 11 Table 15 Ehternet cable 4 11 Table 16 Ethernet cable Color Code 4 12 Table 17 Ethernet Cable Ele...

Page 11: ...hing Chapter 7 PTP 820C HP Detailed Configurations Description Chapter 8 Installation Instructions for Configurations with Channel Filter Based Branching Chapter 9 Installing PTP 820C HP on Third Party Antenna Adaptors Chapter 10 Acceptance and Commisioning Procedures Contacting Cambium Networks Support website https support cambiumnetworks com Main website http www cambiumnetworks com Sales enqui...

Page 12: ...he customer or anyone acting on the customer s behalf to abide by the instructions system parameters or recommendations made in this document Cross references References to external publications are shown in italics Other cross references emphasized in blue text in electronic versions are active links to the references This document is divided into numbered chapters that are divided into sections ...

Page 13: ...or one 1 year from date of shipment from Cambium Networks or a Cambium distributor Cambium Networks warrants that hardware will conform to the relevant published specifications and will be free from material defects in material and workmanship under normal use and service Cambium shall within this time at its own option either repair or replace the defective product within thirty 30 days of receip...

Page 14: ...d security practices Security aspects to be considered are protecting the confidentiality integrity and availability of information and assets Assets include the ability to communicate information about the nature of the communications and information about the parties involved In certain instances Cambium makes specific recommendations regarding security practices however the implementation of th...

Page 15: ...owing format Warning Warning text and consequence for not following the instructions in the warning Cautions Cautions precede instructions and are used when there is a possibility of damage to systems software or individual items of equipment within a system However this damage presents no danger to personnel A caution has the following format Caution Caution text and consequence for not following...

Page 16: ...quipment in EU countries Disposal of Cambium equipment European Union EU Directive 2002 96 EC Waste Electrical and Electronic Equipment WEEE Do not dispose of Cambium equipment in landfill sites For disposal instructions refer to http www cambiumnetworks com support Disposal of surplus packaging Do not dispose of surplus packaging in landfill sites In the EU it is the individual recipient s respon...

Page 17: ... scenarios PTP 820C HP supports cutting edge capacity boosting techniques such as QPSK to 2048 QAM and Header De Duplication to offer a high capacity solution for every network topology and every site configuration Its green compact all outdoor configuration makes PTP 820C HP ideal for any location This chapter includes Important Notes Safety Precautions Declared Materials Pre Installation Instruc...

Page 18: ...or modifications of equipment not expressly approved by the manufacturer could void the user s authority to operate the equipment and the warranty for such equipment PTP 820C HP is intended for installation in a restricted access location PTP 820C HP must be installed and permanently connected to protective earth by qualified service personnel in accordance with applicable national electrical code...

Page 19: ...ational exposure limit is not of concern to workers operating in or around the parabolic dish antenna General Equipment Precautions Caution To avoid malfunctioning or personnel injuries equipment or accessories kits plug in unit installation requires qualified and trained personnel Changes or modifications not expressly approved by Cambium Networks can void user s authority to operate the equipmen...

Page 20: ...tplugg og eller via annet jordtilkoplet utstyr og er tilkoplet et kabel TV nett kan forårsake brannfare For å unngå dette skal det ved tilkopling av utstyret til kabel TV nettet installeres en galvanisk isolator mellom utstyret og kabel TV nettet Utrustning som är kopplad till skyddsjord via jordat vägguttag och eller via annan utrustning och samtidigt är kopplad till kabel TV nät kan i vissa fall...

Page 21: ...s die hier angegebenen kann dies gefährliche Strahlung verursachen Caution Beachten Sie beim Arbeiten mit PTP 820C HP das folgende Stromschlag und Gefahrenrisiko Durch Abtrennen einer Stromquelle wird nur ein Caution Stromversorgungsmodul abgetrennt Um die Einheit vollständig zu isolieren trennen Sie alle Stromversorgungen ab Maschinenlärminformations Verordnung 3 GPSGV der höchste Schalldruckpege...

Page 22: ...tion Instructions phn 4794_002v000 Page 1 6 Pre Installation Instructions This chapter describes the Pre Installation instructions for PTP 820C HP This chapter includes Packing Transportation and Storage Unpacking Inspection ...

Page 23: ...ired the packed equipment must be stored in a dry and cool environment and out of direct sunlight in accordance with ETS 300 019 1 1 Class 1 2 Unpacking The equipment is packed in sealed plastic bags and moisture absorbing bags are inserted Any separate sensitive product such as printed boards are packed in anti static handling bags The equipment is further packed in special designed cases Marking...

Page 24: ...rk replanning PTP 820C HP can be used with wide diplexer based branching enabling direct mount installation Diplexers can be used for direct mount configurations of up to 4 0 PTP 820C HP can also be used with channel filter based branching enabling configurations of up to 8 0 per polarization in remote mount and all indoor configurations To maximize operational flexibility both diplexers and chann...

Page 25: ...are Overview phn 4794_002v000 Page 2 9 PTP 820C HP Hardware Overview PTP 820C HP features an all outdoor dual carrier architecture consisting of a single unit Figure 1 PTP 820C HP Rear View Left and Front View Right Figure 2 Cable Gland Construction ...

Page 26: ...t 1 for GbE traffic o Electric 10 100 1000Base T RJ 45 Data Port 2 for GbE traffic o Optical 1000Base X SFP Data Port 3 EXT o Optical 1000Base X SFP o Optical MIMO port for data sharing Management and Protection o Electric 10 100Base T RJ 45 2 RF Interfaces Standard interface per frequency band RSL interface Dual pin connector Source sharing TNC connector Grounding screw ...

Page 27: ... of PTP 820C HP in a specific band as well as the availability of any specific mediation device Presenting a specific component in this manual does not indicate that it is available for ordering Please consult with your pre sales engineer for specific component availability information Diplexer Based Branching Radio Components Figure 4 PTP 820C HP Radio Unit Figure 5 PTP 820C HP Diplexer Unit ...

Page 28: ...Chapter 2 PTP 820C HP Overview System Components Diplexer Based Branching phn 4794_002v000 Page 2 12 Diplexer Based Branching Branching Components Figure 6 OMT Figure 7 Space Diversity Branching Device ...

Page 29: ...Chapter 2 PTP 820C HP Overview System Components Diplexer Based Branching phn 4794_002v000 Page 2 13 Figure 8 Splitter Figure 9 Dual Coupler Splitter Circulator ...

Page 30: ...ter 2 PTP 820C HP Overview System Components Diplexer Based Branching phn 4794_002v000 Page 2 14 Diplexer Based Branching Accessory Components Figure 10 Remote Pole Mount Figure 11 Remote Pole Mount Adaptor ...

Page 31: ... Branching Note Refer to the product roadmap for availability of PTP 820C HP in a specific band as well as the availability of any specific mediation device Presenting a specific component in this manual does not indicate that it is available for ordering Please consult with your pre sales engineer for specific component availability information ...

Page 32: ... HP Overview System Components Channel Filter Based Branching phn 4794_002v000 Page 2 16 Figure 12 PTP 820C HP OCU Unit Rail Body Figure 13 PTP 820C HP Branching Pole Profile Part of PTP 820C HP Filters Remote Mount Kit ...

Page 33: ...Chapter 2 PTP 820C HP Overview System Components Channel Filter Based Branching phn 4794_002v000 Page 2 17 Figure 14 Short U Bend Figure 15 Long U Bend Figure 16 Splitter Coupler Figure 17 Termination ...

Page 34: ...mponents Channel Filter Based Branching phn 4794_002v000 Page 2 18 Figure 18 Radio Unit and Diplexer Unit In PTP 820C HP Port 1 is the upper port located closest to the handle and Port 2 is the lower port located closest to the Ethernet ports ...

Page 35: ...ines the radio unit Model placeholders Table 1 PTP 820C HP Radio Unit Model Placeholders P N Description Notes C060082B219A PTP 820C HP Basic Radio 6 GHz Eth SFP MIMO Port C070082B324A PTP 820C HP Basic Radio 7 GHz Eth SFP MIMO Port C080082B174A PTP 820C HP Basic Radio 8 GHz Eth SFP MIMO Port C110082B128A PTP 820C HP Basic Radio 11 GHz Eth SFP MIMO Port C060082B220A PTP 820C HP Basic Radio 6 GHz E...

Page 36: ...L241A PTP 820C HP RFU D HP Diplexer U6 GHz TR160A Ch7W12 Lo 6607 5 6672 5MHz N060082L242A PTP 820C HP RFU D HP Diplexer U6 GHz TR160A Ch13W16 Hi 6827 5 6872 5MHz N060082L243A PTP 820C HP RFU D HP Diplexer U6 GHz TR160A Ch13W16 Lo 6667 5 6712 5MHz N060082L222A PTP 820C HP RFU D HP Diplexer U6 GHz TR 340A CH1W4 Hi 6781 6939MHz N060082L223A PTP 820C HP RFU D HP Diplexer U6 GHz TR 340A CH1W4 Lo 6441 6...

Page 37: ...6 5 7485 5MHz N070082L328A PTP 820C HP RFU D HP Diplexer 7 GHz TR 154A CH2W3 Hi 7608 5 7667 5MHz N070082L329A PTP 820C HP RFU D HP Diplexer 7 GHz TR 154A CH2W3 Lo 7454 5 7513 5MHz N070082L330A PTP 820C HP RFU D HP Diplexer 7 GHz TR 154A CH3W4 Hi 7636 5 7695 5MHz N070082L331A PTP 820C HP RFU D HP Diplexer 7 GHz TR 154A CH3W4 Lo 7482 5 7541 5MHz N070082L332A PTP 820C HP RFU D HP Diplexer 7 GHz TR 15...

Page 38: ...OMT 6 GHz N070082L340A PTP 820C HP RFU D HP OMT 7 8 GHz N110082L141A PTP 820C HP RFU D HP OMT 11 GHz N060082L244A PTP 820C HP RFU D HP OMT Plate Adaptor 6 GHz N110082L148A PTP 820C HP RFU D HP OMT Plate Adaptor 11 GHz N070082L341A PTP 820C HP RFU D HP OMT Plate Adaptor 7 8 GHz N060082L227A PTP 820C HP RFU D HP Dual Coupler 6 GHz N110082L142A PTP 820C HP RFU D HP Dual Coupler 11 GHz N070082L342A PT...

Page 39: ...d various PTP 820C HP configurations Since the SKU is frequency dependent please check with Cambium Sales Reprsenttive for P N Table 4 PTP 820C HP Branching Unit Marketing Models Description PTP 820C HP OCU Mounting Kit PTP 820C HP Filters Cover Branching U Bend ff GHz PTP 820C HP FLT Cover Branch Long U Bend ff GHz PTP 820C HP PDR100 CPR90G WG 50ohm termination kit ff GHz PTP 820C HP Filters Cove...

Page 40: ... N070082L344A N110082L146 A SPLITTER KIT N060082L23 2A N070082L339A N110082L145 A OMT KIT N060082L22 6A N070082L340A N110082L141 A SPACE DIVERSITY KIT N060082L23 4A N070082L345A N110082L147 A REMOTE MOUNT KIT N000082L16 6A N000082L166A N000082L16 6A OMT PLATE ADAPTOR N060082L24 4A N070082L341A N110082L148 A WG Kit N060082L15 6A N070082L004A N110082L105 A Table 6 Antenna Circ Adapters for OMT Anten...

Page 41: ...ve can be used recommended Other antenna types using the flanges listed in the table below may also be used Table 7 Antenna Flanges Frequency Band Range GHz Rect WG Flange Des Radio Side Remote Flange Des 6 L U GHz 5 8 7 1 WR137 UDR701 7 8 GHz 7 1 8 5 WR112 UBR841 10 11 GHz 10 0 11 7 WR90 UBR1001 If a different antenna type CPR flange is used a flange adaptor is required Please contact your Cambiu...

Page 42: ...L169A PTP 820 Outdoor_DC_cbl_2x14AWG_drum 305m N000082L170A PTP 820 Outdoor_DC_cbl_2x10AWG_drum 305m Important Notes The unit must only be installed by service personnel The unit must have a permanent connection to protective grounding Data port 2 Data port 3 the Management port and the TNC connector do not provide protection from over voltages on telecommunication networks for host equipment user...

Page 43: ... 4 Class 4 1 Temperature range for continuous operating temperature with high reliability 33 C 27 F to 55 C 131 F Temperature range for exceptional temperatures tested successfully with limited margins 45 C 49 F to 60 C 140 F Humidity 5 RH to 100 RH IEC529 IP66 Storage ETSI EN 300 019 1 1 Class 1 2 Transportation ETSI EN 300 019 1 2 Class 2 3 ...

Page 44: ...keting Description Quantity N000082L116A PTP 820 GROUND CABLE FOR IDU and ODU 1 Required Tools Metric offset wrench key wrench 3 Metric wrench 10mm Procedure 1 On the front of each PTP 820C HP unit loosen the nut plain washer and serrated washer from the GND stud using the metric offset hexagon key and the wrench ...

Page 45: ...o the main ground bar or terminal ground bar of the site 5 Perform a resistance test between the 2 lugs of the GND cable Verify that the result is 0 2 ohms Notes The unit s earthing screw terminal shall be permanently connected to protective earth in a building installation in accordance with applicable national code and regulations by a service person Any outdoor antenna cable shield shall be per...

Page 46: ...20C HP cable installation and grounding procedure This chapter includes Minimum and Maximum Cable Diameter Cable Grounding Surge Protection Available Cable Options Securing the Cables Special Instructions for use of Glands Connecting an Optical Fiber Cable and SFP Connecting a DC Power Cable Connecting the Ethernet Cable Management Connection for 1 1 2 2 HSB Configurations ...

Page 47: ...02v000 Page 4 4 Minimum and Maximum Cable Diameter To fit the gland the outer cable diameter should be between 6 10 mm This applies to all glands on both the PTP 820C HP unit and the PoE Injector To fit the grounding clamp the outer diameter of CAT5E Ethernet Cables must be between 6 7 1mm ...

Page 48: ...ee connecting a DC power cable no grounding is required For Ethernet cables the shielded Ethernetcable SF UTP construction must be grounded to the antenna tower at the top next to the PTP 820 unit and the indoor cabinet and every 50m using the Ethernet Cable Grounding Kit N000082L017A Figure 19 Grounding cable To Connect the Grounding kit Table 10 Cable Grounding Kit P N Description N000082L017A P...

Page 49: ... Grounding phn 4794_002v000 Page 4 6 Procedure 1 Strip the Cable jacket 2 Place the cable in the middle of the grounding bracket 3 Close the grounding bracket around the cable 4 Tighten the two screws to secure the grounding bracket around the cable ...

Page 50: ...Chapter 4 Cable Installation and Grounding Cable Grounding phn 4794_002v000 Page 4 7 5 Install the grounding lug on the grounding bar or directly to the tower 6 Tighten the grounding lug ...

Page 51: ...40 VDC to 60 VDC Warning Availability of a UPS Uninterrupted Power Source battery backup and emergency power generator is desirable The power supply must have grounding points on the AC and DC sides Caution The user power supply GND must be connected to the positive pole in the PTP 820C HP power supply Any other connection may cause damage to the system Note For the warranty to be honored you must...

Page 52: ... standards set forth in the Surge Protection Requirements section of the PTP 820C HP Technical Description provided the Ethernet cables were prepared according to the instructions in Connecting the Ethernet Cable In areas in which severe lighting conditions are likely to occur it is strongly recommended to add additional protection by placing lightning protectors on all electrical Ethernet cables ...

Page 53: ...ptical CABLE SM 50m N000082L141A PTP 820 Optical CABLE SM 80m N000082L142A PTP 820 Optical CABLE SM 100m N000082L143A PTP 820 Optical CABLE SM 150m Fiber Optic Cables Multi Mode Table 12 Fiber Optic Cables Multi Mode Part Number Description N000082L019A PTP 820 Outdoor_DC_cbl_2x18AWG_drum 305m N000082L065A PTP 820 DC Connnector DC Cable and Connector Table 13 DC cable and connector Part Number Des...

Page 54: ...T_20M N000082L064A PTP 820 C SOURCE_SHARING_10M N000082L137A PTP 820 C SOURCE_SHARING_20M N000082L060A PTP 820 C MIMO or Prot management cable 10m N000082L136A PTP 820 C MIMO or Prot management cable 20m Ethernet Cable and Specifications Table 15 Ehternet cable Part Number Description N000082L016A PTP 820 CAT5E Outdoor 100m drum This cable is suitable for Fast Ethernet Gigabit Ethernet The followi...

Page 55: ...n 4794_002v000 Page 4 12 Figure 20 Cable design 1 Conductor 2 Insulation 3 Screen Alu Pet foil Alu outside 4 Tinned copper braid 5 Jacket Table 16 Ethernet cable Color Code Pair Wire A Wire B 1 WHITE blue BLUE 2 WHITE orange ORANGE 3 WHITE green GREEN 4 WHITE brown BROWN ...

Page 56: ...d Voltage rating 70V Shielding Braid Foil Pinout Ethernet Cable Mechanical Environmental Requirements Jacket PVC double UV resistant Outer diameter 7 1mm in order to be compatible with the grounding clamp CAT5E gnd kit Operating and Storage temperature range 40 C 85 C Flammability rating According to UL 1581 VW1 IEC 60332 1 RoHS According to Directive 2002 95 EC Outdoor DC Cable Specifications Tab...

Page 57: ...tallations Stranding stranded Voltage rating 600V for 9 AWG 300V for 14 AWG Spark test 4KV Dielectric strength 2KV AC min Mechanical Environmental Requirements Jacket PVC double UV resistant Outer diameter 6 10 5 mm Operating Storage temperature range 40 C 85 C Flammability rating According to UL 1581 VW1 IEC 60332 1 RoHS According to Directive 2002 95 EC ...

Page 58: ...ing the Cables All cables should be secured at every meter on site using either a T Rups kit Model Outdoor Ties or cable clamps When using the T Rups kit take special care to apply the proper amount of force in order to avoid damage to the cable This is especially important for optical SFP cables ...

Page 59: ...Each PTP 820C HP unit is supplied with two glands If additional glands are required they must be ordered separately in kits of five glands each Table 19 Glands kit Part Number Description N000082L014A PTP 820 Glands_x5_KIT In order to remove the plastic plugs for the unit you can use the flange of supplied glands to disconnect them See the figures below ...

Page 60: ...ables using long glands The gland is supplied assembled 1 Before inserting a cable you must disassemble the gland cap and gland rubber from the gland body 2 Slide the gland cap into the cable 3 Slide the gland rubber into the cable 4 Slide the cable into the body of the gland If a gland cap is being used see Step 5 make sure to leave enough space for the gland cap to fit into the gland without dis...

Page 61: ... 6 The M28 gland cap has hook on top After attaching the gland cap to the gland connect a rope to the hook and use this to lift the gland and cable up to the radio unit Before securing the gland into the radio unit remove the gland cap 7 If an M28 gland cap is used to close the gland when raising the gland and cable to the radio unit remove the gland cap from the gland at this point by unscrewing ...

Page 62: ... gland Verify that the gland thread is not damaged and tighten the gland again 10 Insert the main part of the gland into the thread in the radio body and tighten until there is full contact and the gasket is fully contained between the gland and the radio and cannot be seen Tighten the gland gently and make sure there is no resistance If there is resistance stop immediately and thread out the glan...

Page 63: ...he gland onto the main part of the gland and make sure that the main part of the gland does not have an additional swivel after the rear portion is secured Note If the main portion of the gland is rotated while the rear portion is seizing the cable this may ruin the cable connector 12 Secure the cable to the lip of the gland using a tie wrap ...

Page 64: ...ting an Optical Fiber Cable and SFP To connect an optical fiber cable and the SFP transceiver 1 Use a pre assembled cable 2 Split the connector into two separate LC Connectors one for each fiber 3 Remove the gland cap and rubber from the gland body 4 Slide the gland cap into the cable 5 Slide the rubber into the cable ...

Page 65: ...he cable to a radio unit on a tower this step is crucial to prevent the cable from slipping from the gland which could damage the connector 8 Connect the fibers to the SFP transceiver Listen for the click to ensure that it is fully inserted 9 Remove the tie wrap securing the cable to the gland Note A new tie wrap must be used to secure the cable to the gland at the end of the procedure as describe...

Page 66: ...and ensure it is aligned with the taped hole in the unit Tightening the gland at an angle can ruin the thread on the gland and prevent proper sealing of the interface Tighten the gland gently and make sure there is no resistance If there is resistance stop immediately thread out the gland and verify that the gland threads are not damaged Then tighten the gland again Caution If the gland thread is ...

Page 67: ...Chapter 4 Cable Installation and Grounding Connecting an Optical Fiber Cable and SFP phn 4794_002v000 Page 4 24 ...

Page 68: ...must be ordered separately See DC Cable and Connector To connect a DC power cable 1 Strip off 45 mm from the cable jacket 2 Expose 10 mm at the edge of each of the two wires 3 Insert the power cable into the gland 4 Insert the power cable wires into the power connector 5 Insert the power cable wires into the power connector Match to the 0V wire and to the 48V wire ...

Page 69: ...Chapter 4 Cable Installation and Grounding Connecting a DC Power Cable phn 4794_002v000 Page 4 26 6 Tighten the two top screws 7 Plug the power cable with connector into the PTP 820C HP power connector ...

Page 70: ...e gland make sure the gland is even with the cover Tighten the gland gently and make sure there is no resistance If there is resistance stop immediately and verify that the gland is not being inserted at an angle Tightening the gland at an angle can ruin the thread on the gland and prevent proper sealing of the interface 10 Tighten the gland cap 11 Secure the cable to the gland with a tie wrap ...

Page 71: ...nectivity it is recommended to use pre assembled Ethernet cables Preparing the Ethernet Cable and Plug in Field Note To ensure proper grounding the RJ 45 plug must be shielded with a crimping tail Table 20 Materials for preparing Ethernet Data Cables P N Description N000082L016A PTP 820 CAT5E Outdoor 100m drum N000082L014A PTP 820 Glands_x5_KIT N000082L017A PTP 820 Grounding Kit for CAT5e F UTP 8m...

Page 72: ...eath 7 Separate the wires and place the twisted braid between the separated wires 8 Insert the wires into the RJ45 plug Verify that each wire is fully inserted into the front of the RJ45 plug and in the correct order according to the pinouts shown in Section Outdoor Ethernet Cable Specifications The sheath of the Ethernet cable should extend into the plug by about 13 mm and held in place by the cr...

Page 73: ...res extend to the front of the RJ45 plug and make good contact with the metal contacts in the RJ45 plug 13 Push back the CAT5E plug cover on the connector plug Note It is recommended that the newly prepared cable be tested with a Cable Analyzer such as the FLUKE DTX 1800 or the equivalent to make sure the cable complies with ANSI TIA EIA 568 B 2 Make sure to verify both connectivity and grounding ...

Page 74: ...o the gland cap and into the rubber gland 3 Insert the CAT5E cable into the gland body Connection of Ethernet Cable to PTP 820C HP To connect the Ethernet cable to the PTP 820C HP 1 Remove the relevant cap from the PTP 820C HP radio You can use the side of the gland to unscrew the cap 2 Connect the CAT5E cable to the PTP 820C HP ...

Page 75: ...ghtening the gland make sure the gland is even with the cover Tighten the gland gently and make sure there is no resistance If there is resistance stop immediately and verify that the gland is not being inserted at an angle Tightening the gland at an angle can ruin the thread on the gland and prevent proper sealing of the interface 4 Tighten the gland cap ...

Page 76: ...Chapter 4 Cable Installation and Grounding Connecting the Ethernet Cable phn 4794_002v000 Page 4 33 5 Secure the cable to the gland using a tie wrap ...

Page 77: ...from Cambium in various lengths but users can also prepare them in the field The following sections explain how to prepare and connect these cables Preparing a MIMO Protection Signaling Cable The MIMO Protection signaling cables require the following pinouts Figure 21 MIMO Protection Signaling Cable Pinouts Note Other than the pinout connection described above the cable should be prepared accordin...

Page 78: ...and any HSB protection configuration must be performed manually using out of band management MIMO Protection signaling port Prot A MIMO Protection signaling cross cable as described above should be connected between this port and the other MIMO Prot port of the second splitter on the mate PTP 820C HP unit The following figure demonstrates a 4x4 MIMO configuration in which both PTP 820C HP units ar...

Page 79: ...tion for 1 1 2 2 HSB Configurations phn 4794_002v000 Page 5 1 Chapter 5 Generic Installation Procedures and Notes This chapter describes the generic nstallation procedure and notes for PTP 820C HP This chapter includes General Notes Concerning All Installation Procedures ...

Page 80: ...ach dual core configuration can be considered as single core configuration hardware ready for its dual core counterpart Therefore you should follow the same procedure for 2 0 SP installation if you want to install a 1 0 SP HW ready for 2 0 SP One of the major benefits of the PTP 820C HP and the dual core architecture is that upgrading can be done remotely by uploading the correct software license ...

Page 81: ... on the radio use 5 Nm torque When fastening a waveguide to the radio or mediation device use the following torque according to frequency and screw type 6 GHz M5 10 32 3 5 Nm 7 8 15 GHz M4 8 32 2 5 Nm In addition when connecting the diplexer to the radio and the radio to the mediation device screws should be cross tightened gradually In other words partially tighten one screw then partially tighte...

Page 82: ... to provide maximum flexibility In most cases the Diplexers unit should be attached to the antenna or mediation device first Then attach the radio unit to the Diplexers unit The PTP 820C HP radio can be assembled to the diplexers kit prior to installation then mounted to the antenna or mediation device as a single unit For details see Installing the Diplexer on the Radio Figure 24 PTP 820C HP Inst...

Page 83: ... 6 Installation Instructions for Configurations with Diplexe Based Branching Torque Requirements phn 4794_002v000 Page 6 5 Figure 25 PTP 820C HP Installation Attaching the Diplexers Unit Before the Radio Unit ...

Page 84: ...TP 820C HP Radio Unit 1 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 1 See Models for Diplexer Unit Required Tools Torque Wrench With Metric Hexagon Socket Key Wrench 4 Allen key Procedure 1 Prior to the installation remove the sticker which is covering the diplexer ports on the Diplexer unit and the sticker that covers the TRX ports on the radio unit 2 Position the diplexer unit on the r...

Page 85: ...ns for Configurations with Diplexe Based Branching Torque Requirements phn 4794_002v000 Page 6 7 Figure 26 Fitting the Diplexer Unit to the Radio Unit Radio Side Figure 27 Fitting the Diplexer Unit to the Radio Unit Diplexer Unit Side ...

Page 86: ...pter 6 Installation Instructions for Configurations with Diplexe Based Branching Torque Requirements phn 4794_002v000 Page 6 8 Figure 28 Radio and Diplexer Units Together Figure 29 Hook and Carrying Handle ...

Page 87: ... unit to the radio unit using the eight M5 screws supplied with the radio unit First gently tighten the screws in the order shown in Figure 38 Then strongly tighten the screws in the same order Figure 30 Securing the Diplexer Unit to the Radio Unit 5 Proceed to install the PTP 820C HP in the desired configuration as described in the following sections ...

Page 88: ...ation Direct Mount 2 2 HSB Double Polarization Remote Mount 2 2 HSB Single Polarization Direct Mount 2 x 2 0 Dual Polarization Direct Mount 2 x 2 0 Dual Polarization Remote Mount 2 x 2 0 Single Polarization Direct Mount 2x2 LoS MIMO Direct Mount 2x2 LoS MIMO Remote Mount 4x4 LoS MIMO Direct Mount 4 0 Dual Polarization 2 2HSB Single Dual Polarization Direct Mount 4 0 with Dual Circulator Direct Mou...

Page 89: ...also be used for 1 0 DP HW ready for 2 0 DP configuration List of Items Item Description Quantity Model 1 PTP 820C HP Radio Unit 1 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 1 See Models for Diplexer Unit 3 PTP 820C HP OMT Kit 1 DXDH MD OMT ff 4 CIRC CIRC Adaptor 1 Per Antenna Vendor Required Tools Metric offset hexagon key set Metric wrench key set ...

Page 90: ...follow the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2 Connect the OMT kit to the antenna and secure it with four screws Important Verify that the O ring is properly mounted between the antenna transition and the OMT ...

Page 91: ...al Polarization Direct Mount Page 7 4 3 Connect the PTP 820C HP radio dual coupler to the OMT kit using the four M8 captive screws and washers supplied and tighten the screws Important Verify that the O rings are properly mounted between the OMT ports and the radio ...

Page 92: ...nnas up to six feet For standard interface antennas six feet and larger no OMT and no Circ Circ Adaptor are used and the flexible waveguides are connected directly to the antenna flanges For instructions how to connect the waveguides to the antenna flanges refer to the antenna vendor s documentation Note This procedure can also be used for 1 0 DP HW ready for 2 0 DP configurations ...

Page 93: ...rectangular transition swap the O ring and install the circular transition instead 2 Connect the OMT kit to the antenna and secure it with four screws Item Description Quantity Remarks 1 PTP 820C HP Radio Unit 1 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 1 See Models for Diplexer Unit 3 PTP 820C HP OMT Kit 1 4 Flexible Waveguide Kit PTP 820C HP 2 5 PTP 820C HP DC Adaptor Remote Mount Ki...

Page 94: ...2 0 Dual Polarization Remote Mount Page 7 7 Important Verify that the O ring is properly mounted between the antenna transition and the OMT 3 Mount and tighten the Remote MountAdapter to the PTP 820C HP OMT ports using the screws supplied with the adapter kit ...

Page 95: ... ports using the screws supplied with the flexible waveguide kit Important Verify that the O rings are correctly mounted between the OMT ports and each flexible waveguide 5 Mount and tighten the PTP 820C HP DC pole mount to the pole using the four washers and screws supplied with the PTP 820C HP DC pole mount kit 7 8 GHz 10 11 GHz Figure 31 6 GHz Mounting the First Adaptor ...

Page 96: ...o For 6 11 GHz configurations use 39 Nm torque Figure 32 Remote Pole Mount Kit 6 11 GHz Figure 33 Remote Pole Mount Kit 4 5 GHz 6 Mount and tighten the PTP 820C HP Remote Mount Adaptor plate supplied in PTP 820C HP Adaptor Remote Mount kit to the PTP 820C HP Pole Mount using the four flat screws supplied with thePTP 820C HP Adaptor Remote Mount kit ...

Page 97: ...2 0 Dual Polarization Remote Mount Page 7 10 Figure 34 Remote Pole Mount Kit 6 11 GHz Figure 35 Remote Pole Mount Kit 4 5 GHz 7 Mount and tighten the PTP 820C HP Radio to the PTP 820C HP Pole Mount using the four flat screws supplied with the PTP 820C HP Radio ...

Page 98: ... Configurations Description 2 0 Dual Polarization Remote Mount Page 7 11 8 Mount and tighten both Flexible WGs with their O ring to the PTP 820C HP Remote Mount Adaptor ports using the four screws supplied with each Flexible WG kit ...

Page 99: ...cription Quantity Model 1 PTP 820C HP RADIO 1 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 1 See Models for Diplexer Unit 3 PTP 820C HP Splitter Kit 1 Required Tools Metric offset hexagon key set Phillips 1 2 screwdriver Procedure 1 Adjust the twist on the Splitter Kit Perform one of the following steps according to the required polarization horizontal or vertical o For horizontal polariz...

Page 100: ...t Mount Page 7 13 o For vertical polarization locate the twist with the letter V on top 2 Mount and tighten the PTP 820C HP Splitter Kit on the antenna using the four M8 screws and washers Important Verify that the O ring is properly mounted between the antenna transition and the splitter ...

Page 101: ...Polarization Direct Mount Page 7 14 3 Connect the PTP 820C HP DC radio to the splitter kit using the four M8 captive screws and washers supplied and tighten the screws Important Verify that the O rings are properly mounted between the OMT ports and the radio dual coupler ...

Page 102: ...el 1 PTP 820C HP RADIO 2 See Models for Radio Unit 2 PP 820C HP Diplexer Unit 2 See Models for Diplexer Unit 3 PTP 820C HP OMT KIT 1 4 PTP 820C HP DUAL COUPLER KIT 1 5 CIRC CIRC ADAPTOR 1 Per Antenna Vendor Required Tools Metric offset hexagon key set Metric wrench key set Procedure 1 Prior to the installation follow the antenna manufacturer s instructions to use the circular adaptor Remove the ex...

Page 103: ...nect the PTP 820C HP OMT Kit to the antenna and secure it with four screws Verify existence of the O ring Important Verify that the O ring is properly mounted between the antenna transition and the OMT 3 Connect the PTP 820C HP Dual Coupler Kit to the OMT Kit using four M8 screws and washers and tighten the screws ...

Page 104: ...rify that the O rings are properly mounted between the OMT ports and the dual coupler 4 Mount and tighten the PTP 820C HP DC radio unit to both sides of the Dual Coupler Kit using the supplied captive screws and washers Pay attention that the O rings are correctly mounted on the radio ports of the PTP 820C HP Dual Coupler ...

Page 105: ...ption 2 2 HSB Double Polarization Direct Mount Page 7 18 5 Connect the MIMO signaling cable between the management ports of both units For additional instructions on preparing and connecting this cable refer to Preparing a MIMO Protection Signaling Cable ...

Page 106: ...tions List of Items Item Description Quantity Model 1 PTP 820C HP RADIO 2 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 2 See Models for Diplexer Unit 3 PTP 820C HP OMT KIT 1 4 PTP 820C HP DUAL COUPLER KIT 1 5 FLEXIBLE WG KIT 2 6 PTP 820C HP POLE MOUNT KIT 1 7 PTP 820C HP Adaptor Remote Mount KIT 1 8 CIRC CIRC ADAPTOR 1 Per Antenna Vendor Required Tools Metric offset hexagon key set Metric...

Page 107: ...edure 1 Prior to the installation follow the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2 Connect the OMT Kit to the antenna and secure it with four screws Verify the existence of the O ring ...

Page 108: ...ion Remote Mount Page 7 21 3 Mount and tighten the Remote Mount Adapter to the PTP 820C HP OMT ports using the screws supplied with the adapter kit 4 Mount and tighten the O ring and the flexible waveguide to the adapter ports using the screws supplied with the flexible waveguide kit ...

Page 109: ...22 Important Verify that the O rings are correctly mounted between the OMT ports and each flexible waveguide 5 Mount and tighten the PTP 820C HP DC pole mount to the pole using the four washers and screws supplied with the PTP 820C HP DC pole mount kit See Steps 5 and 6 in 2 0 Dual Polarization Remote Mount ...

Page 110: ... PTP 820C HP Remote Mount Adaptor plate supplied inPTP 820C HP Adaptor Remote Mount kit to the PTP 820C HP Pole Mount using the four flat screws supplied with the PTP 820C HP Adaptor Remote Mount kit 7 Mount and tighten the PTP 820C HP Radio to the PTP 820C HP Pole Mount using the four flat screws supplied with the PTP 820C HP Radio ...

Page 111: ...zation Remote Mount Page 7 24 8 Mount and tighten the PTP 820C HP Dual Coupler to the PTP 820C HP Pole Mount using the four screws and washers that are supplied with the PTP 820C HP Dual Coupler kit Pay attention that the O rings are mounted on the PTP 820C HP Remote Mount Adaptor ...

Page 112: ...Polarization Remote Mount Page 7 25 9 Mount and tighten the PTP 820C HP radios on each side of the PTP 820C HP Dual Coupler using the screws assembled on PTP 820C HP radio Payattention that the O rings are correctly assembled on the radio port of the PTP 820C HP Dual coupler ...

Page 113: ... supplied with each Flexible Waveguide Kit to the PTP 820C HP Dual Coupler antenna ports Tighten the screws and washers supplied with the Flexible Waveguide Kit 11 Connect the protection signaling cable between the management ports of both units For additional instructions on preparing and connecting this cable refer to Preparing a MIMO Protection Signaling Cable ...

Page 114: ...y Model 1 PTP 820C HP RADIO 2 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 2 See Models for Diplexer Unit 3 PTP 820C HP SPLITTER KIT 1 4 PTP 820C HP DUAL COUPLER KIT 1 Required Tools Metric offset hexagon key set Metric wrench key set Phillips 1 screwdriver Procedure 1 Adjust the twist on the Splitter Kit Perform one of the procedures below according to the required polarization horizonta...

Page 115: ...Chapter 7 PTP 820C HP Detailed Configurations Description 2 2 HSB Single Polarization Direct Mount Page 7 28 o For vertical polarization locate the twist with the letter V on top ...

Page 116: ...ers and tighten the screws 3 Connect the PTP 820C HP Dual Coupler Kit to the Splitter Kit using four M8 screws and washers and tighten the screws 4 Mount and tighten the PTP 820C HP radio unit to both sides of the Dual Coupler Kit using the supplied captive screws and washers Pay attention that the O rings are correctly mounted on the radio ports of the PTP 820C HP Dual Coupler ...

Page 117: ...on 2 2 HSB Single Polarization Direct Mount Page 7 30 5 Connect the protection signaling cable between the management ports of both units For additional instructions on preparing and connecting this cable refer to Preparing a MIMO Protection Signaling Cable ...

Page 118: ...C HP RADIO 2 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 2 See Models for Diplexer Unit 3 PTP 820C HP OMT KIT 1 4 PTP 820C HP DUAL COUPLER or SPLITTER KIT 1 5 CIRC CIRC ADAPTOR 1 Per Antenna Vendor Required Tools Metric offset hexagon key set Metric wrench key set Procedure 1 Prior to the installation follow the antenna manufacturer s instructions to use the circular adaptor Remove the e...

Page 119: ...7 PTP 820C HP Detailed Configurations Description 2 x 2 0 Dual Polarization Direct Mount Page 7 32 2 Connect the PTP 820C HP OMT Kit to the antenna and secure it with four screws Verify existence of the O ring ...

Page 120: ...C HP Dual Coupler Kit to the OMT Kit using four M8 screws and washers and tighten the screws 4 Mount and tighten the PTP 820C HP DC radio unit to both sides of the Dual Coupler Kit using the supplied captive screws and washers Pay attention that the O rings are correctly mounted on the radio ports of the PTP 820C HP Dual Coupler ...

Page 121: ...onfigurations List of Items Item Description Quantity Models 1 PTP 820C HP RADIO 2 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 2 See Models for Diplexer Unit 3 PTP 820C HP OMT KIT 1 4 PTP 820C HP DUAL COUPLER OR DUAL SPLITTER KIT 1 5 FLEXIBLE WG KIT 2 6 PTP 820C HP DC POLE MOUNT KIT 1 7 PTP 820C HP DC REMOTE MOUNT ADAPTOR KIT 1 8 CIRC CIRC ADAPTOR 1 Per Antenna Vendor Required Tools Metr...

Page 122: ...use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2 Connect the OMT kit to the antenna and secure it with four screws Important Verify that the O ring is properly mounted between the antenna transition and the OMT 3 Mount and tighten the appropriate adapter to the PTP 820C HP OMT ports using the screws supplied with the ...

Page 123: ...Chapter 7 PTP 820C HP Detailed Configurations Description 2 x 2 0 Dual Polarization Remote Mount Page 7 36 Figure 36 6 GHz Mounting the First Adaptor Figure 37 6 GHz Mounting the Second Adaptor ...

Page 124: ... there is a single adaptor Figure 38 Mounting the Single Adaptor for 7 8 10 and 11 GHz 4 Mount and tighten the O ring and the flexible waveguide to the adapter ports using the screws supplied with the flexible waveguide kit Important Verify that the O rings are correctly mounted between the OMT ports and each flexible waveguide ...

Page 125: ...20C HP DC pole mount to the pole using the four washers and screws supplied with the PTP 820C HP DC pole mount kit 6 Mount and tighten the PTP 820C HP Remote Mount Adaptor plate supplied in PTP 820C HP Adaptor Remote Mount kit to the PTP 820C HP Pole Mount using the four flat screws supplied with the PTP 820C HP Adaptor Remote Mount kit ...

Page 126: ...P Detailed Configurations Description 2 x 2 0 Dual Polarization Remote Mount Page 7 39 7 Mount and tighten the PTP 820C HP Radio to the PTP 820C HP Pole Mount using the four flat screws supplied with the PTP 820C HP Radio ...

Page 127: ...Model 1 PTP 820C HP RADIO 2 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 2 See Models for Diplexer Unit 3 PTP 820C HP Splitter Kit 1 4 PTP 820C HP Dual Splitter Kit 1 Required Tools Metric offset hexagon key set Metric wrench key set Phillips 1 screwdriver Procedure 1 Adjust the twist on the Splitter Kit Perform one of the procedures below according to the required polarization horizontal...

Page 128: ...Chapter 7 PTP 820C HP Detailed Configurations Description 2 x 2 0 Single Polarization Direct Mount Page 7 41 For vertical polarization locate the twist with the letter V on top ...

Page 129: ... 2 0 Single Polarization Direct Mount Page 7 42 2 Mount the Dual Core Kit on the antenna using four M8 screws and washers and tighten the screws 3 Connect the PTP 820C HP Dual Coupler Kit to the Splitter Kit using four M8 screws and washers and tighten the screws ...

Page 130: ... Polarization Direct Mount Page 7 43 4 Mount and tighten the PTP 820C HP DC radio unit to both sides of the Dual Coupler Kit using the supplied captive screws and washers Pay attention that the O rings are correctly mounted on the radio ports of the PTP 820C HP Dual Coupler ...

Page 131: ...2HSB SP configurations ACCP Protected List of Items Item Description Quantity Model 1 PTP 820C HP RADIO 2 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 2 See Models for Diplexer Unit 3 Adaptor Remote Mount Kit 1 4 PTP 820C HP SPLITTER KIT 1 5 PTP 820C HP DUAL COUPLER KIT 1 6 FLEXIBLE WG KIT 2 7 RFU C POLE MOUNT KIT 2 Required Tools Metric offset hexagon key set Metric wrench key set Philli...

Page 132: ...ur flat screws supplied with the PTP 820C HP Adaptor Remote Mount kit 2 Mount and tighten the PTP 820C HP Splitter to the PTP 820C HP Pole Mount using the four captive screws and washers that are assembled to the PTP 820C HP Splitter kit 3 Mount and tighten the PTP 820C HP Dual Coupler to the PTP 820C HP Splitter using the four captive screws and washers that are supplied with the PTP 820C HP Dual...

Page 133: ... HP Detailed Configurations Description 2 2 HSB Single Polarization Remote Mount Page 7 46 4 Attach the Diplexer unit to the Dual Coupler using 8 M4 screws provided with the Diplexer kit as shown below using 20Nm torque ...

Page 134: ...he Diplexer unit 5 Secure the edges of the Diplexer unit to the Dual Coupler using the four M8 captive screws and washers supplied with the Diplexer kit using 20Nm torque These screws are colored blue in the following picture Be sure to tighten the screws in the same diagonal manner as in the previous step 4 M8 Screws 6 Attach the Radio unit to the Diplexer unit using the 8 M5 captive screws suppl...

Page 135: ...n Pin Hole Location Pin Hole Not Shown 7 Repeat steps 4 6 to attach the second Diplexer unit and the second Radio unit to the other side of the Dual Coupler Dual Splitter or Dual Circulator 1 Connect the Flexible Waveguide and Sealing Gasket supplied with the Flexible Waveguide kit to the RFU C Adaptor plate Tighten the four screws supplied with the Flexible Waveguide kit ...

Page 136: ...Models for Radio Unit 2 PTP 820C HP Diplexer Unit 1 See Models for Diplexer Unit 3 PTP 820C HP Dual Core Kit 1 4 Flexible WG Kit 1 Optional 5 Coax to WG Kit 1 Optional Required Tools Metric offset hexagon key set Phillips 1 2 screwdriver Procedure 1 Adjust the twist on the Splitter Kit Perform one of the procedures below according to the required polarization horizontal or vertical o For horizonta...

Page 137: ...Chapter 7 PTP 820C HP Detailed Configurations Description 2x2 LoS MIMO Direct Mount Page 7 50 o For vertical polarization locate the twist with the letter V on top ...

Page 138: ...er Kit on the antenna using four M8 screws and washers and tighten the screws 3 Connect the PTP 820C HP DC radio to the Splitter kit using the four M8 captive screws and washers supplied and tighten the screws Important Verify that the O rings are properly mounted between the OMT ports and the radio dual coupler ...

Page 139: ...te This procedure can also be used for 1 0 SD configurations List of Items Item Description Quantity Model 1 PTP 820C HP RADIO 1 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 1 See Models for Diplexer Unit 3 PTP 820C HP DC Adaptor Remote Mount KIT 1 Required Tools Metric offset hexagon key set Metric wrench key set ...

Page 140: ...20C HP Adaptor Remote Mount kit to the PTP 820C HP Pole Mount using the four flat screws supplied with the PTP 820C HP Adaptor Remote Mount kit 2 Mount and tighten the PTP 820C HP Radio to the PTP 820C HP Pole Mount using the four captive screws and washers that are supplied with the PTP 820C HP Radio Pay attention that the O rings are mounted on the PTP 820C HP Remote Mount Adaptor ...

Page 141: ...ailed Configurations Description 2x2 LoS MIMO Remote Mount Page 7 54 3 Mount and tighten both Flexible WGs with their O ring to the PTP 820C HP Remote Mount Adaptor ports using the four screws supplied with each Flexible WG kit ...

Page 142: ...is procedure can also be used for 2 2 SD configurations List of Items Item Description Quantity Model 1 PTP 820C HP RADIO 2 See Models for Radio Unit 2 PTP 820C HP Diplexer Unit 2 See Models for Diplexer Unit 3 PTP 820C HP OMT KIT 2 4 MIMO DATA CABLE 1 5 SOURCE SHARING CABLE 1 6 CAT5E MIMO SIGNALING CABLE 1 7 CIRC CIRC ADAPTOR 1 Per Antenna Vendor Required Tools Metric offset hexagon key set Metri...

Page 143: ...ions on installation of the PTP820C OMT and radios see 2 0 Dual Polarization Direct Mount 2 Connect the source sharing cable between both EXT REFPTP 820C HP radio connectors The maximum torque for connecting this cable to the radio is 5Lb in 0 5N m 3 Connect the MIMO data sharing cable between both P3PTP 820C HP ports ...

Page 144: ... Description 4x4 LoS MIMO Direct Mount Page 7 57 4 Connect the MIMO signaling cable between the management ports of both units For additional instructions on preparing and connecting this cable refer to Preparing a MIMO Protection Signaling Cable ...

Page 145: ...0C HP OMT Splitter Kit 1 Required Tools Metric offset hexagon key set Metric wrench key set Procedure 1 Mount the OMT for dual polarization or Splitter for single polarization to the antenna and secure it with four screws Important Verify that the O ring is properly mounted between the antenna transition and the OMT Splitter o If you are using a Splitter adjust the twist on the Splitter Kit 2 Perf...

Page 146: ...Chapter 7 PTP 820C HP Detailed Configurations Description 4 0 Single Dual Polarization Direct Mount Page 7 59 o For vertical polarization locate the twist with the letter V on top ...

Page 147: ...ers and tighten the screws 4 Connect the PTP 820C HP Dual Coupler Kit to the OMT Splitter Kit using four M8 screws and washers and tighten the screws 5 Mount and tighten the PTP 820C HP radio unit to both sides of the Dual Coupler Kit using the supplied captive screws and washers Pay attention that the O rings are correctly mounted on the radio ports of the PTP 820C HP Dual Coupler ...

Page 148: ...n 4 0 Single Dual Polarization Direct Mount Page 7 61 6 Connect the protection signaling cable between the management ports of both units For additional instructions on preparing and connecting this cable refer to Preparing a MIMO Protection Signaling Cable ...

Page 149: ... Page 7 62 4 0 with Dual Circulator Direct Mount The following example illustrates a typical configuration assuming that The regulation specifies a channelization of 8 consecutive 28 38MHz channels 1 8 ch The actual channels in use are channels 1 5 Figure 39 4 0 with Dual Circulator Direct Mount ...

Page 150: ...io Unit 2 PTP 820C HP Diplexer Units 2 See Models for Diplexer Unit 3 PTP 820C HP OMT Kit 1 4 Flexible Waveguide Kit 2 5 PTP 820C HP Dual Circulator Splitter 1 6 Adaptor Remote Mount Kit 1 Required Tools Metric offset hexagon key set Metric wrench key set Procedure 1 Connect the OMT kit to the antenna and secure it with four screws Important Verify that the O ring is properly mounted between the a...

Page 151: ...HP Adaptor Remote Mount kit See Steps 5 and 6 in 2 0 Dual Polarization Remote Mount 3 Mount and tighten the PTP 820C HP Dual Coupler to thePTP 820C HP Pole Mount using the four screws and washers that are supplied with the PTP 820C HP Dual Circulator Splitter kit Make sure that the O rings are mounted on the PTP 820C HP Remote Mount Adaptor 4 Attach the PTP 820 C Diplexer units to the PTP 820 C Du...

Page 152: ...Diplexer unit 5 Secure the edges of the Diplexer unit to the Dual Circulator Splitter using the four M8 captive screws and washers supplied with the Diplexer kit using 20Nm torque These screws are colored blue in the following picture Be sure to tighten the screws in the same diagonal manner as in the previous step 4 M8 Screws 6 Attach the Radio unit to the Diplexer unit using the 8 M5 captive scr...

Page 153: ...h the second Diplexer unit and the second Radio unit to the other side of the Dual Circulator Splitter 8 Connect both Flexible Waveguides and Sealing Gaskets supplied with each Flexible Waveguide Kit to the antenna ports on the Remote Mount Adaptor Tighten the screws and washers supplied with the Flexible Waveguide Kit 9 Attach the OMT Remote Mount Adapter to the OMT using the screws supplied with...

Page 154: ... Description 4 0 Dual Polarization Remote Mount Page 7 67 10 Connect both Flexible Waveguides and Sealing Gaskets supplied with each Flexible Waveguide Kit to the OMT Remote Mount Adaptor using the screws supplied with the Flexible Waveguide kits ...

Page 155: ... Circulator Remote Mount Page 7 68 4 0 with Dual Circulator Remote Mount The following example illustrates a typical configuration assuming that The regulation specifies a channelization of 8 consecutive 28 38MHz channels 1 8 ch The actual channels in use are channels 1 5 ...

Page 156: ...odels for Diplexer Unit 3 Dual Circulator 2 4 PTP 820C HP_MC_DUAL_CIRC_kit_xxG 1 Required Tools Metric offset hexagon key set Metric wrench key set Procedure 1 Mount and tighten the pillar adapter brackets to pole supplied in PTP 820C HP Adaptor Remote Mount kit Tighten the four M10 Hex screws and washers supplied within the kit 6 8 GHz 1 Mount and tighten the PTP 820C HP MC Dual Cir to the PTP 82...

Page 157: ...70 11 GHz only 1 Mount and tighten the PTP 820C HP MC extender to the PTP 820C HP pillar adapter bracket using the four M8 Hex screws and washers supplied within the kit 2 Mount and tighten the PTP 820C HP MC Dual Cir to the PTP 820C HP MC Extender using the four M8 Hex screws and washers supplied within the kit ...

Page 158: ...g the four M8 Hex screws and washers supplied in the PTP 820 Dual Circ kit Pay attention that the O rings on the PTP 820C HP MC Dual Circ are well in place during the mounting 2 Mount and tighten the PTP 820C HP radios to each PTP 820C HP Dual Circ radio port using the four screws assembled on the PTP 820C HP radio Pay attention that the O rings on the PTP 820C HP Dual Circ are well in place durin...

Page 159: ...r screws assembled on the PTP 820C HP radio Pay attention that the O rings on the PTP 820C HP MC Remote mount adapter are well in place during the mounting 4 Mount and tighten the O ring and the Flexible WG to the PTP 820C HP MC Remote mount adapter ports using the four screws supplied with the Flexible WG kit 5 Mount and tighten the O ring and flexible WG to both antenna ports using the four scre...

Page 160: ...ion Dual Circulator Multi Carrier Kit Installation Page 7 73 The following example illustrates a typical configuration assuming The regulation specifies a channelization of 8 consecutive 28 30 MHz channels 1 8ch The actual channels in use are channels 1 5 ...

Page 161: ...Configuration Antenna Ports Low Channels Radio i e Ch1 V H High Channels Radio i e Ch5 V H 1 2 3 4 5 6 7 8 Antenna Ports High Channels Radio i e Ch5 V H Low Channels Radio i e Ch1 V H High Channels Radio i e Ch5 V H Low Channels Radio i e Ch1 V H Lower Band Radio i e 6L Upper Band side i e 6H 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 6H 6L ...

Page 162: ...te mount configuration in which two flexible waveguides are used to connect the two Remote Mount Adaptor ports to an antenna This chapter describes a hub site installation For standard interface antennas six feet and larger no OMT and no Circ Circ Adaptor are used and the flexible waveguides are connected directly to the antenna flanges For instructions how to connect the waveguides to the antenna...

Page 163: ...tor Remove the existing rectangular transition swap the O ring and install the circular transition instead 2 Mount and tighten the Flexible WG to the antenna port using the four screws supplied with the Flexible WG kit 3 Mount and tighten the PTP 820C HP Remote Mount Adaptor plate supplied in PTP 820C HP Adaptor Remote Mount kit to the PTP 820C HP Pole Mount using the four flat screws supplied wit...

Page 164: ...n AFR 1 0 Hub Site Page 7 77 4 Mount and tighten the PTP 820C HP to the PTP 820C HP Pole Mount using the four captive screws and washers that are supplied with the PTP 820C HP Pay attention that the O rings are mounted on the PTP 820C HP Remote Mount Adaptor ...

Page 165: ...h their O ring to the PTP 820C HP Remote Mount Adaptor ports using the four screws supplied with each Flexible WG kit The following figure shows the complete installation Note This figure shows an installation with horizontal polarization Vertical polarization can also be used The same polarization must be used for both links ...

Page 166: ...bly Explains how to assemble each individual component used in channel filter based branching configurations Channel Filter Based Branching Configurations Explains how to assemble channel filter based branching configurations with references to the relevant component assembly instructions Channel Filter Based Branching Component Assembly Assembling the OCU Mounting Kit This section explains how to...

Page 167: ...80 Figure 41 Branching Pole Profile Figure 42 Branching Pillars with Screws Nuts and Washers Required Tools Metric offset wrench key wrench set Procedure 1 Mount and tighten the two Branching Pillars to a pole with a diameter of 114 mm using the four M10x150 screws four washers and eight nuts supplied with the OCU Mounting kit Use torque of 45 Nm ...

Page 168: ...lter Based Branching Channel Filter Based Branching Component Assembly Page 8 81 2 Mount and tighten the Branching Pole to one of the Branching Pillars using the four M10x25 screws supplied with the OCU Mounting kit Use torque of 45 Nm 2 1 M10x25 Screws Holes for Screws ...

Page 169: ...Included in OCU kit 3 OCU Rail 1 per OCU kit Included in OCU kit 4 PTP 820C HP Radio 2 4 See Models for Radio Unit 5 Screw Socket hex head SS DIN 912 M8x25 A2 70 4 per OCU kit Included in OCU kit 6 Screw Socket hex head SS DIN 912 M8x30 A2 70 2 per OCU kit Included in OCU kit 7 Washer Plain SS DIN 125 A8 4 A2 70 6 per OCU kit Included in OCU kit 8 Washer Helical spring lock SS DIN 127 B8 A2 70 6 p...

Page 170: ...anne Filter Based Branching Channel Filter Based Branching Component Assembly Page 8 83 Figure 43 1 2 4 OCU Kit Body Rail and M8x25 Screws 1 2 4 3 PTP 820C HP Radio 4 M8x25 Screw 5 M8x30 Screw 6 Washers Plain 7 Washers Helical spring lock 8 Branching Pole Profile ...

Page 171: ...5 Nm M8 screws with OCU 20 Nm Configuration Options for OCU Kit Assembly Attach the OCU rail to the OCU body using the 4 M8 X 25 screws helical washers and flat washers provided with the OCU kit The rail can be oriented in either of the two ways shown in Figure 1 and Figure 2 With the nose of the rail protruding to the left when facing the inside of the OCU Figure 46 With the nose of the rail prot...

Page 172: ...1 2 4 Figure 48 shows the Left Rail and Right Rail configurations in the context of a full configuration in which four radios and four OCUs are attached to the Branching Pole Profile Important The figure below is illustrative only Do not mount the OCU to the Branching Pole Profile until the radio unit has been attached to the OCU as described below Figure 48 Left and Right Rail Configurations Toge...

Page 173: ...screws without tightening them in a diagonal fashion as shown in Figure 50 Once all the screws have been partially fastened tighten all the screws in the same order using 2 5 Nm torque Figure 49 Attaching the Radio to the OCU 1 3 Figure 50 Order of Fastening Screws 1 6 4 8 7 2 5 3 Connecting the Combined OCU and Radio to the Branching Pole Profile Once the OCU and radio unit have been connected mo...

Page 174: ...Rail Underneath the Nose of the Branching Pole Profile 3 8 2 2 Level the OCU radio unit so that the nose of the OCU Rail is locked underneath and inside of the nose of the Branching Pole Profile Figure 52 Figure 52 Final Position of OCU Radio Locked into Branching Pole Profile 3 8 2 3 Partially attach the OCU radio unit to the Branching Pole Profile with the two M8 30 screws included in the OCU ki...

Page 175: ... to the Branching Pole Profile 2 8 5 3 1 Waveguide Assemblies At this point in the installation you must install all required waveguide assemblies such as U Bends Flexible Waveguides and Terminations For instructions refer to the specific type of configuration you are installing in Channel Filter Based Branching Configurations Tightening the M8 30 Screws When you have finished installing all waveg...

Page 176: ...y Once all the screws have been fully fastened the complete assembly is ready to be raised via a crane Make sure to loop the cable through both shackles on the OCU Rail as shown in Figure 54 You must also loop the cable through all the PTP 820C HP radio handles in the configuration Figure 54 Raising the Assembly Via Crane Long U Bends Terminations Terminations Cable Shackles ...

Page 177: ... PTP 820C HP Branching Short U Bend Kit Depends on Configuration 2 8 32 Socket Hex Screws 12 Per U Bend Embedded in U Bend Figure 55 1 Short U Bend Required Tools Imperial Allen key set Required Torque 8 32 socket hex screws embedded in U Bend 2 5 Nm Procedure 1 Before attaching the U Bend make sure that the U Bend is already fitted with bushings in both ports The U Bend should be supplied with bu...

Page 178: ... Channe Filter Based Branching Channel Filter Based Branching Component Assembly Page 8 91 the OCUs as shown in the figure below Make sure the sealing gaskets supplied with the U Bend are in place before mounting the U Bends Sealing Gaskets 1 Use 2 5 Nm Torque ...

Page 179: ...ds on Configuration 2 8 32 Socket Hex Screws 12 Per U Bend Embedded in U Bend Figure 56 1 Long U Bend Required Tools Imperial Allen key set Required Torque 8 32 socket hex screws embedded in U Bend 2 5 Nm Procedure 1 Before attaching the U Bend make sure that the U Bend is already fitted with bushings in both ports The U Bend should be supplied with bushings to seal the RF 2 Long U Bends are conne...

Page 180: ... Channel Filter Based Branching Component Assembly Page 8 93 ports of the OCUs as shown in the figure below Make sure the sealing gaskets supplied with the U Bend are in place before mounting the U Bends Sealing Gaskets 1 2 1 Radio OCU 2 Radio OCU 3 Radio OCU 4 Radio OCU 1 Use 2 5 Nm Torque ...

Page 181: ...tem Description Quantity Model 1 PTP 820C HP Termination Kit Depends on Configuration 2 8 32 Socket Hex Screws 8 Per Termination Kit Included in Termination Kit 3 Washer Helical Spring Lock SS DIN 127 B8 A2 70 8 Per Termination Kit Included in Termination Kit 4 Washer Plain SS DIN 125 A8 4 A2 70 8 Per Termination Kit Included in Termination Kit 5 Sealing Gasket 1 Per Termination Kit Included in Te...

Page 182: ...nds on Configuration 3 6 GHz 10 32 Screws 7 11 GHz 8 32 Screws 8 Per Kit Included in Splitter Coupler Kit 4 6 GHz Washer Helical spring lock SS ANSI 10 7 11GHz Washer Helical spring lock SS ANSI 8 8 Per Kit Included in Splitter Coupler Kit 5 6GHz Washer Plain SS DIN 125 A5 3 A2 70 7 11GHz Washer Plain SS DIN 125 A4 3 A2 70 8 Per Kit Included in Splitter Coupler Kit 6 Sealing Gasket 1 Per Kit Inclu...

Page 183: ...Page 8 96 Procedure A Remote Mount Splitter or Remote Mount Coupler is attached to the OCU using the 8 screws helical spring washers and plain washers provided with the Coupler or Splitter kit as shown in the figure below The other interfaces can be connected to the antenna or flexible waveguide depending on the configuration 1 4 2 5 3 OCU ...

Page 184: ...t 4 PTP 820C HP OCU Kit 1 See Models for OCU Unit 5 PTP 820C HP Termination Kit 1 6 Flexible Waveguides 2 Procedure 1 Assemble the OCU Mounting Kit See Assembling the OCU Mounting Kit 2 Assemble the OCU attach the PTP 820C HP radio to the OCU and connect the radio OCU assembly to the Branching Pole Profile Use a Left Rail Configuration to assemble the OCU See Assembling the OCU 3 On the side of th...

Page 185: ...ons for Configurations with Channe Filter Based Branching Channel Filter Based Branching Configurations Page 8 98 5 Connect a flexible waveguide from the upper radio port of the OCU on the side facing away from the pole to the antenna ...

Page 186: ...RM MOUNT kit 4 PTP 820C HP OCU Kit 1 See Models for OCU Unit 5 PTP 820C HP Termination Kit 2 6 PTP 820C HP OMT Kit 1 7 Flexible Waveguide Kit 2 Procedure 1 Assemble the OCU Mounting Kit See Assembling the OCU Mounting Kit 2 Assemble the OCU attach the PTP 820C HP radio to the OCU and connect the radio OCU assembly to the Branching Pole Profile Use a Left Rail Configuration to assemble the OCU See ...

Page 187: ...nfigurations with Channe Filter Based Branching Channel Filter Based Branching Configurations Page 8 100 1 On the side of the OCU facing away from the pole connect the flexible waveguides between the radio ports and the OMT Vertical Horizontal ...

Page 188: ...tion Kit 1 6 PTP 820C HP Branching Short U Bend Kit 2 7 Flexible Waveguides 2 Procedure 1 Assemble the OCU Mounting Kit See Assembling the OCU Mounting Kit 2 Assemble an OCU using a Left Rail Configuration attach the PTP 820C HP radio to the OCU and connect the radio OCU assembly to the Branching Pole Profile See Assembling the OCU 3 Assemble the second OCU using a Right Rail Configuration attach ...

Page 189: ...ions Page 8 102 Connect a flexible waveguide from the lower radio port of the OCU on the left to the upper radio port of the OCU on the right Connect a flexible waveguide from the upper radio port of the OCU on the left to the antenna Connect a Termination to the lower radio port of the OCU on the right See Assembling a Termination ...

Page 190: ...e Assembling the OCU Mounting Kit 2 Assemble an OCU using a Left Rail Configuration attach the an PTP 820C HP radio to the OCU and connect the radio OCU assembly to the Branching Pole Profile See Assembling the OCU 3 Assemble the second OCU using a Right Rail Configuration attach the second PTP 820C HP radio to the OCU and connect the radio OCU assembly to the Branching Pole Profile See Assembling...

Page 191: ...ity Model 1 PTP 820C HP Radio Unit 3 See Models for Radio Unit 2 PTP 820C HP Branching Pole Profile 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 PTP 820C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 PTP 820C HP OCU Kit 3 See Models for OCU Unit 5 PTP 820C HP Termination Kit 1 6 PTP 820C HP Branching Short U Bend Kit 2 7 PTP 820C HP Branching Long U Bend Kit 1 8 Flexible Wav...

Page 192: ...l Configuration and one using a Right Rail Configuration Attach an PTP 820C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Assembling the OCU Left Left Right 3 On the side of the OCU facing the pole 4 Attach Short U Bends between the radio ports of the two OCUs See Assembling a Short U Bend 5 Attach a Termination to the ...

Page 193: ...e OCU on the left to the antenna 8 Connect a flexible waveguide from the lower radio port of the OCU on the left to the upper radio port of the adjacent OCU 9 Connect a Long U Bend between the lower radio port of the middle OCU and the lower radio port of the OCU on the right See Assembling a Long U Bend 10 On the OCU on the right connect a flexible waveguide from the upper radio port to the lower...

Page 194: ...of OCU Mounting kit FXDH RM MOUNT kit 4 PTP 820C HP OCU Kit 3 See Models for OCU Unit 5 PTP 820C HP Termination Kit 2 6 PTP 820C HP Branching Short U Bend Kit 2 7 PTP 820C HP Branching Long U Bend Kit 2 8 PTP 820C HP OMT Kit 1 9 Flexible Waveguides 2 Procedure 1 Assemble the OCU Mounting Kit See Assembling the OCU Mounting Kit 2 Assemble three OCUs two using a Left Rail Configuration and one using...

Page 195: ...age 8 108 Left Left Right 3 On the side of the OCU facing the pole 4 Attach Short U Bends between the radio ports of the two OCUs See Assembling a Short U Bend 5 Attach a Termination to each radio port of the OCU on the right See Assembling a Termination 6 Connect the OMT to the antenna See Steps 1 4 in 2 0 Dual Polarization Remote Mount ...

Page 196: ...Filter Based Branching Configurations Page 8 109 7 On the side facing away from the pole 8 On the OCU to the left connect a flexible waveguide from each radio port of the OCU to the OMT 9 Connect a Long U Bend between each set of radio ports on the two OCUs to the right See Assembling a Long U Bend ...

Page 197: ...ity Model 1 PTP 820C HP Radio Unit 4 See Models for Radio Unit 2 PTP 820C HP Branching Pole Profile 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 PTP 820C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 PTP 820C HP OCU Kit 4 See Models for OCU Unit 5 PTP 820C HP Termination Kit 1 6 PTP 820C HP Branching Short U Bend Kit 4 7 PTP 820C HP Branching Long U Bend Kit 1 8 Flexible Wav...

Page 198: ...our OCUs two using a Left Rail Configuration and two using a Right Rail Configuration Attach an PTP 820C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Assembling the OCU Left 1 Left 3 Right 2 Right 4 3 On the side of the OCU facing the pole for each pair of adjacent OCUs attach two Short U Bends between the adjacent rad...

Page 199: ...de from the upper radio port of OCU 1 to the lower radio port of OCU 2 6 Connect a flexible waveguide from the lower radio port of OCU 1 to the antenna 7 Connect a flexible waveguide from the lower radio port of OCU 3 to the upper radio port of OCU 4 8 Connect a Long U Bend between the upper radio port of OCU 2 and the upper radio port of OCU 3 See Assembling a Long U Bend 9 Attach a Termination t...

Page 200: ...of OCU Mounting kit FXDH RM MOUNT kit 4 PTP 820C HP OCU Kit 4 See Models for OCU Unit 5 PTP 820C HP Termination Kit 2 6 PTP 820C HP Branching Short U Bend Kit 4 7 PTP 820C HP Branching Long U Bend Kit 2 8 PTP 820C HP OMT Kit 1 9 Flexible Waveguides 2 Procedure 1 Assemble the OCU Mounting Kit See Assembling the OCU Mounting Kit 2 Assemble four OCUs two using a Left Rail Configuration and two using ...

Page 201: ... Branching Configurations Page 8 114 Left 1 Left 3 Right 2 Right 4 3 On the side of the OCU facing the pole for each pair of adjacent OCUs attach two Short U Bends between the adjacent radio ports See Assembling a Short U Bend 4 Connect the OMT to the antenna See Steps 1 4 in 2 0 Dual Polarization Remote Mount ...

Page 202: ...On the side facing away from the pole refer to the numbering in the figure above 6 Connect a flexible waveguide from each of the radio ports on OCU 1 to the OMT 7 Connect Long U Bends between the upper and lower radio ports of OCU 2 and OCU 3 See Assembling a Long U Bend 8 Attach a Termination to each radio port on OCU 4 See Assembling a Termination ...

Page 203: ...em Description Quantity Model 1 PTP 820C HP Radio Unit 2 See Models for Radio Unit 2 PTP 820C HP Branching Pole Profile 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 PTP 820C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 PTP 820C HP OCU Kit 2 See Models for OCU Unit 5 PTP 820C HP Termination Kit 6 6 PTP 820C HP Coupler Kit 1 7 Flexible Waveguides 2 ...

Page 204: ...rations Page 8 117 Procedure 1 Assemble the OCU Mounting Kit See Assembling the OCU Mounting Kit 2 Assemble two OCUs both using a Left Rail Configuration Attach an PTP 820C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Assembling the OCU Left 1 Left 2 ...

Page 205: ...ee Assembling a Termination 4 On the side facing away from the pole refer to the numbering in the figure above Connect a Coupler to the upper radio port of OCU 1 See Assembling a Splitter or Coupler for Filter Based Branching Connect a flexible waveguide from the Coupler to the upper radio port of OCU 2 Attach a Termination to each of the lower radio ports See Assembling a Termination 5 Attach a w...

Page 206: ...0C HP Radio Unit 4 See Models for Radio Unit 2 PTP 820C HP Branching Pole Profile 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 PTP 820C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 PTP 820C HP OCU Kit 4 See Models for OCU Unit 5 PTP 820C HP Termination Kit 4 6 PTP 820C HP Branching Short U Bend Kit 4 7 PTP 820C HP Splitter Kit Depends on Configuration 8 PTP 820C HP SPLITTER...

Page 207: ...Branching Channel Filter Based Branching Configurations Page 8 120 Procedure 1 Prior to the installation follow the antenna manufacturer s instructions to use the circular adaptor Remove the existing rectangular transition swap the O ring and install the circular transition instead ...

Page 208: ...ching Channel Filter Based Branching Configurations Page 8 121 2 Connect the OMT Kit to the antenna and secure it with four screws Verify the existence of the O ring 3 Mount and tighten the Remote Mount Adapter to the PTP 820C HP OMT ports using the screws supplied with the adapter kit ...

Page 209: ...el Filter Based Branching Configurations Page 8 122 4 Mount and tighten the O ring and the flexible waveguide to the adapter ports using the screws supplied with the flexible waveguide kit 5 Important Verify that the O rings are correctly mounted between the OMT ports and each flexible waveguide ...

Page 210: ...CUs two using a Left Rail Configuration and two using a Right Rail Configuration Attach an PTP 820C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Assembling the OCU Left 1 Left 3 Right 2 Right 4 8 On the side of the OCU facing the pole for each pair of adjacent OCUs attach two Short U Bends between the adjacent radio po...

Page 211: ...adio port of OCU 1 See Assembling a Splitter or Coupler for Filter Based Branching 11 Connect a flexible waveguide from the upper Splitter to the upper radio port of OCU 3 12 Connect a flexible waveguide from the lower Splitter to the lower radio port of OCU 3 13 Attach a Termination to each of the radio ports on OCU 2 and OCU 4 See Assembling a Termination 14 Attach waveguides between the Splitte...

Page 212: ...Description Quantity Model 1 PTP 820C HP Radio Unit 2 See Models for Radio Unit 2 PTP 820C HP Branching Pole Profile 1 Part of OCU Mounting kit FXDH RM MOUNT kit 3 PTP 820C HP Branching Pillar 2 Part of OCU Mounting kit FXDH RM MOUNT kit 4 PTP 820C HP OCU Kit 2 See Models for OCU Unit 5 PTP 820C HP Termination Kit 4 6 PTP 820C HP Coupler Kit 2 7 PTP 820C HP OMT Kit 1 8 Flexible Waveguides 2 ...

Page 213: ...ble two OCUs both using a Left Rail Configuration Attach an PTP 820C HP radio to each OCU and connect the radio OCU assemblies to the Branching Pole Profile as shown in the following figure See Assembling the OCU Left 1 Left 2 3 Connect the OMT to the antenna See Steps 1 4 in 2 0 Dual Polarization Remote Mount 4 On the side of the OCU facing the pole attach a Termination to each of the four radio ...

Page 214: ...age 8 127 5 On the side facing away from the pole refer to the numbering in the figure above 6 Connect a Coupler to each radio port of OCU 1 See Assembling a Splitter or Coupler for Filter Based Branching 7 Connect a flexible waveguide from each Coupler to each radio port of OCU 2 8 Attach a waveguide between the antenna and the Coupler ...

Page 215: ...Valuline Antenna Convert kit 6GHz N110082L003A PTP 820 Andrew Valuline Antenna Convert kit 11GHz N110082L004A PTP820 Radiowave Antenna Conversion kit Exalt Cambium 11 GHz 2ft N110082L005A PTP820 Radiowave Antenna Conversion kit Exalt Cambium 11 GHz 3ft N110082L006A PTP820 Radiowave Antenna Conversion kit Exalt Cambium 11 GHz 4ft N110082L007A PTP820 Radiowave Antenna Conversion kit Exalt Cambium 11...

Page 216: ...Installing PTP 820C HP on Third Party Antenna Adaptor Channel Filter Based Branching Configurations Page 9 129 Note For instructions how to install these third party adaptors refer to the RFU C Installation Guide ...

Page 217: ...CommScope s ValuLine 3 antennas 1 6ft However since there are some unique cases in which CommScope provided special antennas which are not supported by these adaptors it is recommended that you supply your Cambium Networks representative with a picture of the current antenna back plain side in order to confirm the antenna s compatibility prior to implementing this solution You can also check the f...

Page 218: ... procedure is to verify correct installation and operation of the installed link and the interoperability with customer end equipment Cambium s Acceptance and Commissioning procedure includes the following stages Site Acceptance Procedure Commissioning of Radio Link The Site Acceptance Procedure is a checklist that summarizes the installation requirements of the site at which the products were ins...

Page 219: ...NA MOUNTING Antenna mount type Mount is of sufficient height to clear local obstructions OK Mount is safely positioned to not cause a safety hazard OK Mount is secure and perpendicular OK Mount is grounded as per site specifications OK All steelwork is Galvanized or Stainless Steel as appropriate OK 3 ANTENNA Antenna type model and size Antenna is securely fixed to mount OK Antenna is grounded as ...

Page 220: ...s are secured using washers and lock washers as appropriate OK Flexible waveguide is secured to the pole OK 6 CAT5 Fiber Optic CABLE Overall cable length Cable type CAT5 connectors assembled properly on the cable OK Cable connected securely to ODU and IDU OK Cable connector is covered by gland and secure by cable tie at the ODU OK At the ODU cable has a service drip loop to prevent moisture from e...

Page 221: ... m recommended OK Flexible WG has no sharp bends kinks or crushed areas All bends are per manufacturer specifications OK Flexible WG point of entry to building shelter is weather proof OK Flexible WG ends are properly labeled OK 8 DC POWER SUPPLY Two Inputs Measured DC voltage input to the IDU 40 5 to 60 VDC Power Supply maximum current Power Supply is properly grounded OK DC power backup type IDU...

Page 222: ...ssioning Procedures Site Acceptance Procedure Page 10 4 SITE ACCEPTANCE CHECKLIST continued 10 REMARKS NOTES 11 GENERAL INFORMATION Site accepted by Name Title Company Signature Date Site approved by Name Title Company Signature Date ...

Page 223: ...ger an extra sway brace is fitted to the mounting frame of the antenna This sway brace should not be mounted to the same pole as the antenna but should be installed directly back to the tower or an alternative point o Antenna Water Drain Plugs are fitted and removed where appropriate Some antennas have moisture drain plugs installed at various points around the antenna The purpose of these plugs i...

Page 224: ...ces Test Connect Ethernet Packet Analyzer to the GbE port Use physical loop at remote end or connect second analyzer Run Packet Loss test for at least one hour load rate as per Cambium s specifications for the chosen MRMC Connect Ethernet Packet Analyzer to the FE port Use physical loop at remote end or connect second analyzer Run Packet Loss test for at least one hour load rate as per Cambium s s...

Page 225: ...d that you are able to perform changes to the link configuration frequency channel Tx power system name time date etc Verify that correct parameters are reported when performing the above Verify that there are no active alarms on the link If the management station is located at a remote site Network Operation Center verify that the management station can manage the link and receive traps ...

Page 226: ...r tracking your installations and to provide essential data for Cambium Networks Upon completing the Commissioning Log send the log to Cambium Networks support center at https support cambiumnetworks com PTP 820 LINK COMMISSIONING LOG 1 GENERAL INFORMATION Customer Radio model Configuration Radio link code Site 1 name add Site 2 name add 2 ODU RFU Site 1 Site 2 ODU model ODU p n ODU s n ODU SW Tx ...

Page 227: ...viation from exp RSL 4 dB 5 COMMISSIONING TESTS Site 1 Site 2 Line loopback Pass Pass ODU loopback Pass Pass Radio BER Pass Pass FE test Pass Pass GbE test Pass Pass 6 MANAGEMENT CONFIGURATION Site 1 Site 2 Eth IP Address Eth IP mask Default router In band VLAN 7 REMARKS NOTES 8 INSTALLATION INFORMATION Installed by Name Company Date Signature Commissioned by Name Company Date Signature ...

Reviews: