PTP 670 QUICK START GUIDE
PAGE 26
Terminate with RJ45 connectors and glands
Attention Check that the crimp tool matches the RJ45 connector, otherwise the cable or
connector may be damaged.
Thread the cable gland (with black cap) onto the main drop cable.
Strip the cable outer sheath and fit the RJ45 connector load bar.
Fit the RJ45 connector housing as shown. To ensure there is effective strain relief, locate the cable inner
sheath under the connector housing tang. Do not tighten the gland nut:
Hoist and fix the main drop cable
Warning Failure to obey the following precautions may result in injury or death:
Use the hoisting grip to hoist one cable only. Attempting to hoist more than one cable
may cause the hoisting grip to break or the cables to fall.
Do not use the hoisting grip for lowering cable unless the clamp is securely in place.
Maintain tension on the hoisting grip during hoisting. Loss of tension can cause
dangerous movement of the cable and result in injury or death to personnel.
Do not release tension on the grip until after the grip handle has been fastened to the
supporting structure.
Do not apply any strain to the RJ45 connectors.
Attention Do not lay the drop cable alongside a lightning air terminal.
Hoist the top end of the main drop cable up to the top LPU, following the hoist manufacturer’s instructions.
When the cable is in position, fasten the grip handle to the supporting structure and remove the hoist line.
Connect the main drop cable to the top LPU by following the procedure Connect the drop cable to the ODU
(PSU port) and LPU on page 16.
Run the main drop cable to the site of the bottom LPU.
Attach the main drop cable to the supporting structure using site approved methods.