Chapter 2: Tools
Using Spectrum Analyzer tool
Page
2-320
Spectrum Analyzer page of AP
The Spectrum Analyzer page of AP is explained in
Table 96 Spectrum Analyzer page attributes - AP
Attribute
Meaning
Display Data Path
Both means that the vertical and horizontal paths are displayed or an
individual path may be selected to display only a single-path reading.
Data
For ease of parsing data and to facilitate automation, the spectrum analyzer
results may be saved as an XML file. To save the results in an XML formatted
file, right-click the “SpectrumAnalysis.xml” link and save the file.
Display
Instantaneous means that each reading (vertical bar) is displayed with two
horizontal lines above it representing the max power level received (top
horizontal line) and the average power level received (lower horizontal line)
at that frequency.
Averaging means that each reading (vertical bar) is displayed with an
associated horizontal line above it representing the max power level
received at that frequency.
Summary of Contents for PMP 450 AP
Page 51: ...Chapter 1 Configuration Quick link setup Page 1 23 ...
Page 155: ...Chapter 1 Configuration Configuring security Page 1 127 ...
Page 163: ...Chapter 1 Configuration Configuring security Page 1 135 ...
Page 164: ...Chapter 1 Configuration Configuring security Page 1 136 ...
Page 193: ...Chapter 1 Configuration Configuring radio parameters Page 1 165 ...
Page 194: ...Chapter 1 Configuration Configuring radio parameters Page 1 166 ...
Page 195: ...Chapter 1 Configuration Configuring radio parameters Page 1 167 ...
Page 206: ...Chapter 1 Configuration Configuring radio parameters Page 1 178 ...
Page 210: ...Chapter 1 Configuration Configuring radio parameters Page 1 182 ...
Page 636: ...Chapter 5 Troubleshooting Logs Page 5 16 Figure 95 SM Authorization log ...