PMP 400/430 and PTP 200/230 Series Configuration and User Guide
pmp-0042 (March 2014)
Page 49 of 98
Procedure 2: Finding collocation values using Frame Calculators
Using the
Tools => Frame Calculator
on an OFDM module, enter the desired Downlink
Data %, Range, and Control Slot settings, click Calculate, and observe the “Rec SEQ
Start” value.
Using the
Tools => Frame Calculator
on an FSK module, enter the desired Downlink
Data %, Range, and Control Slot settings, click Calculate, and observe the “Rec SEQ
Start” value.
Iterate, usually adjusting the FSK Downlink Data % and the OFDM Downlink Data %
values by a few percent each time, until the “Rec SEQ Start” times of all collocated
modules are within 300 bit times of each other.
Configure the OFDM modules using the resulting OFDM values, and the FSK modules
using the resulting FSK values.
The frame calculator page (FSK and OFDM) has been simplified with Release 10.3 to show only
information pertinent to co-location. It will now display AP TX end time and AP RX start time which
allows the operator to more easily calculate co-location duty cycles.
5.8 GHz OFDM
AP TX End Time
and
AP RX Start Time