background image

Connecting 60 GHz cnWave™ Products

40

Connecting to the SFP+ optical module or SFP+ to copper
module to ODU

When ODU is powered through AC/DC PSU, an optical or copper Cat6A Ethernet interface can be
connected to the SFP port of the ODU for data interface.

Adapt the installation procedures in this section as appropriate for SFP interfaces, noting the following
differences from a PSU interface.

Connecting to the SFP+ optical module to ODU

Fitting the long cable gland

Optical SFP interface: Disassemble the long cable gland and thread its components over the LC connector
at the ODU end as shown below.

Copper Cat6a SFP interface : Disassemble the cable gland and thread its components over the RJ45
connector at the ODU end.

1. Disassemble the long cable gland used for optical SFP interface.

Disassemble the long cable gland used for copper SFP interface.

2. Thread each part onto the cable (the rubber bung is split).

3. Fit the parts into the body and lightly screw on the gland nut (do not tighten it).

Optical

Copper

Summary of Contents for cnWave Series

Page 1: ...QUICK START GUIDE 60 GHz cnWave System Release 1 0 ...

Page 2: ...he 3rd Party software supplied material contained in the Cambium products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Cambium Furthermore the purchase of Cambium products shall not be deemed to grant either directly or by implication estoppel or otherwise any license under the copy...

Page 3: ...3000 Client Node 11 V5000 Distribution Node 12 Radio mounting brackets 12 Radio accessories 15 Radio external interfaces 16 V1000 CN 16 V3000 CN 16 V5000 DN 17 60 GHz cnWave radios and mounting bracket option 18 Installing the cnWave radios 18 Attach ground cables to the radio 22 Mounting the ODU on the mast or wall 22 Connecting 60 GHz cnWave Products 35 Connect to the PSU port of the radio 35 Us...

Page 4: ...er injector 39 Connecting to the SFP optical module or SFP to copper module to ODU 40 Connecting to the SFP optical module to ODU 40 Inserting the SFP module 41 Connecting the cable 42 Fitting the gland 43 Removing the cable and SFP module 45 Configuration 45 Accessories Partnumbers 47 Glossary 50 Cambium Networks 51 ...

Page 5: ...ium Networks 60 GHz cnWave platform equipment This Quick Start Guide provides assistance to operators in acquiring a high level understanding of the 60 GHz cnWave platform hardware installation methods initial login procedures and safety warranty information ...

Page 6: ...de CN which acts as a cnWave client cnWave consists of 3 variants V5000 a dual sector Distribution Node V3000 and V1000 are Client Nodes l 60 GHz cnWave V1000 is featured with wide range 80 degrees beamforming for easy installation It is powered by 802 3af PoE and supports up to 2 Gbps for both PTP and PMP configurations l 60 GHz cnWave V3000 is featured with a 44 5 dBi high gain antenna with beam...

Page 7: ...ps DL with channel bonding throughput l Gigabit Ethernet Auxiliary Interface l Powered by passive PoE l Supports Aux PoE out 802 3af at PoE l IP 66 67 V5000 Distribution Node DN l Supports modulations BPSK to 16QAM MCS1 to MCS12 l Dual sector 280 degree antenna with beam forming l 38 dBm EIRP l 10 Gigabit Ethernet l Supports 10G SFP or 1G SFP l 1 8 Gbps UL 1 8 Gbps DL and 3 6 Gbps UL 3 6 Gbps DL w...

Page 8: ...y with current applicable national regulations including radio regulations electrical installation regulations surge protection regulations and working at heights regulations l Installation in accordance with Cambium Networks instructions l Confirming that the equipment settings are compliant with national or regional regulations l Familiarity with training material available on the Cambium Networ...

Page 9: ...e outdoor unit be contracted to a professional installer 4 Always use an appropriately rated and approved AC supply cord set in accordance with the regulations of the country of use 5 Before servicing 60 GHz cnWave equipment always switch off the power supply and unplug it from the PSU Do not disconnect the RJ45 drop cable connectors from the radio while the PSU is connected to the power supply Al...

Page 10: ...h it does not follow the contour or run parallel to the supporting structure l All bends curves and connections must be routed towards the grounding electrode system ground rod or ground bar l Grounding conductors must be securely fastened l Braided grounding conductors must not be used l Approved bonding techniques must be used for the connection of dissimilar metals 13 Radios are not designed to...

Page 11: ... Figure 1 V1000 Client Node front and rear views V3000 Client Node V3000 is an outdoor CN which can be connected to a DN or another V3000 DN wirelessly V3000 supports 10 Gigabit Ethernet interface an 10G SFP interface port and a Gigabit Ethernet Aux interface V3000 can be powered using 60W passive POE or using a AC DC PSU through mini adapter for more information refer power supply and cable lengt...

Page 12: ...x interface Figure 3 V5000 Distribution Node front and rear views Radio mounting brackets V1000 wall and pole mount C000000L136A and C000000L137A The V1000 CN is supplied with a mounting plate and band clamp The mounting plate can be used for mounting the V1000 on a wall or it can be used with the band clamp to mount the V1000 on a pole with diameter in the range 40 mm to 77 mm 1 6 inches to 3 03 ...

Page 13: ...te alignment of the V3000 Figure 6 V3000 precision bracket For precision bracket components refer 60 GHz cnWave User Guide V3000 tilt bracket N000045L002A The tilt bracket Tilt bracket assembly figure below is used to provide elevation adjustment when a V3000 CN or V5000 DN is mounted on a pole The tilt bracket works with poles with diameter in the range 25 mm to 80 mm 0 98 inches to 3 14 inches T...

Page 14: ...n the range 25 mm to 80 mm 0 98 inches to 3 14 inches It provides coarse azimuth but not elevation adjustment Figure 8 V5000 pole mount V5000 wall mount C000000L136A The wall mount Wall mount figure below is used to mount a V5000 DN on a vertical wall It does not provide azimuth or elevation adjustment The wall mount requires additional fixing hardware suitable for the type of wall ...

Page 15: ...temporarily mounted on the bracket using the telescope mounting kit for precision brackets The telescope mounting kit consists of a mounting plate a knurled screw and two rubber O rings Order the telescope mounting kit from Cambium Networks Figure 10 Telescope mounting kit Order a suitable telescope from a specialist supplier specifying the following l Right angle erecting 9x50 mm alignment scope ...

Page 16: ...5 PoE input Standard 802 3af at PoE 100 1000 BASE T Ethernet Data and management V3000 CN Figure 13 External interfaces for V3000 CN Table 2 External interfaces V3000 CN Port name Connector Interface Description SFP SFP 10G BASE SR 10G BASE LR 1G Base SX using optional SFP SFP optical or copper module SFP 1G SX SFP 1G LX using optional SFP optical or copper module Data and management ...

Page 17: ...xternal interfaces for V5000 DN Table 3 External interfaces V5000 DN Port name Connector Interface Description SFP SFP 10G BASE SR 10G BASE LR 1G Base SX using optional SFP SFP optical or copper module SFP 1G SX SFP 1G LX using optional SFP optical or copper module Data and management PSU RJ45 PoE input Passive PoE 100m 1000m 2 5G BASE T 5G BASE T 10G BASE T Ethernet Data and management AUX RJ45 P...

Page 18: ...d cables to the radio 3 Mounting the ODU on the mast or wall Typical installation V1000 V1000 typical installation figure shows typical installation of cnWave CN on a mast and powered through PoE Power Injector 1 Use recommended grounding and Surge Suppressor connections 2 Use recommended cables for interfacing ODU refer powering options and cable length restrictions section in 60 GHz cnWave User ...

Page 19: ...Hardware Overview 19 Figure 15 V1000 typical installation The image before describes the one the installation options For other installation options refer 60 GHz cnWave User Guide ...

Page 20: ...ing and LPU connections 2 Use recommended cables for interfacing ODU refer powering options and cable length restrictions section in 60 GHz cnWave User Guide 3 Always install ODU 0 5 meters below the tip of the pole Figure 16 V3000 typical installation The image before describes the one the installation options For other installation options refer 60 GHz cnWave User Guide ...

Page 21: ...ng and LPU connections 2 Use recommended cables for interfacing ODU refer powering options and cable length restrictions section in in 60 GHz cnWave User Guide 3 Always install ODU 0 5 meters below the tip of the pole Figure 17 V5000 typical installation The image before describes the one the installation options For other installation options refer 60 GHz cnWave User Guide ...

Page 22: ...ODU type and the choice of wall or pole mounting The wall mount plate for V1000 is included with the ODU Order the remaining brackets separately Select the most appropriate bracket mounting arrangement from the options listed in the section Mounting bracket options in 60 GHz cnWave User Guide Refer to individual procedures below for each of the options l V1000 pole mount l V1000 adjustable pole mo...

Page 23: ...1000 pole mount Follow the below instructions to mount V1000 to the pole 1 Insert the hose clamps through mounting plate and clamp to the pole by applying 3 0 Nm torque 2 Insert the radio into the mounting plate on the pole ...

Page 24: ... Follow the below instructions to mount V1000 to the adjustable pole 1 Insert the hose clamps through adjustable pole mount bracket and clamp to the pole by applying 3 0 Nm torque 2 Insert the radio into the adjustable pole mount bracket on the pole ...

Page 25: ... 1 Fix the mounting plate supplied with the V1000 ODU securely to a vertical wall using suitable fixings Note Fixing hardware is not supplied with the V1000 2 Slide the V1000 ODU onto the mounting plate from above ensuring that the spring clip in the mounting plate clicks into place on the radio ...

Page 26: ...hese instructions illustrate the procedure for assembling and using the precision bracket We also illustrate the mounting of the optional alignment telescope Refer 60 GHz cnWave User Guide for further information 1 Insert two of the long 120 mm screws through the azimuth arm and the bracket body The screws locate in the slots in the azimuth arm 2 Fit two flanged M8 nuts to the long screws on the b...

Page 27: ...n adjuster is located in the circular hole in the V3000 mount 4 Fit plain washers and M8 Nyloc nuts to the screws on the back of the bracket base Tighten using a 13 mm spanner 5 Insert the two remaining long 120 mm M8 screws through the bracket body and the azimuth arm The screws locate in the slots in the bracket body ...

Page 28: ...e underside of the bracket base Tighten using a 13 mm spanner 7 Attach the V3000 mount to the radio using the four short M6 bolts Tighten the four bolts to a torque setting of 5 0 Nm 3 7 lb ft using a 13 mm spanner or socket 8 Attach the precision bracket to the pole using the clamp and the remaining flanged nuts Adjust azimuth approximately and tighten the nuts to 10 Nm 7 4 lbft using a 13 mm spa...

Page 29: ... elevation using the fine elevation adjuster 10 Align the antenna azimuth using the fine azimuth adjuster 11 Lock the antenna alignment by tightening the five nyloc nuts see step 5 and step 8 to 10 Nm 7 4 lbft using a 13 mm spanner or socket ...

Page 30: ...s through the bracket body so that the bolt heads engage in the slots as shown Fit two of the short bolts into the side of the bracket body but do not tighten 3 Thread two of the nuts to the long bolts and tighten against the bracket body using a 13 mm spanner Fit the bracket strap and thread the remaining nuts onto the long bolts 4 Fix the assembled bracket body to the pole adjust the azimuth ang...

Page 31: ...low instructions to assemble the Tile bracket with band clamps 1 Follow step 1 of the V3000 V5000 tilt bracket assembly procedure 2 Feed the band clamps through the slots in the bracket body Secure the bracket body to the pole using band clamps not supplied by Cambium ensuring that the arrow in the body is pointing upwards Adjust the azimuth angle and tighten the band clamps to a torque setting of...

Page 32: ... a 13 mm spanner 3 Fix the bracket to the back of the radio using the four short M6 bolts ensuring that the arrow in the plate points towards the top of the radio Tighten the four bolts to a torque setting of 5 0 Nm 3 7 lb ft using a 13 mm spanner or socket 4 Attach the pole mount bracket to the pole using the clamp and the remaining flanged nuts Adjust azimuth and tighten the nuts to 10 Nm 7 4 lb...

Page 33: ...adio using the four short M6 bolts ensuring that the arrow in the plate points towards the top of the radio Tighten the four bolts to a torque setting of 5 0 Nm 3 7 lb ft using a 13 mm spanner or socket 3 Insert the four short M8 bolts into the sides of the bracket body 4 Fit the bracket body to the mounting plate by positioning the short bolts into the open ended slots Tighten the bolts to a torq...

Page 34: ...scope mounted to the V3000 radio using the knurled screw 2 Attach the telescope by looping the two elastic O rings over the ears of the mount ensure that the telescope is located securely in the mount 3 If a telescope with a smaller body is used shorten the O rings by twisting ...

Page 35: ...le the rubber bung is split Assemble the spring clip and the rubber bung 2 Fit the parts into the body and lightly screw on the gland nut do not tighten it 3 Connect the RJ45 plug into the main PSU port of the ODU 4 Rotate the gland clockwise to tightly fit the gland on the PSU port Warning Ensure the cable clamp is not attached tightened at this stage this could cause damage to the RJ45 or PCB ...

Page 36: ...Disconnect the drop cable to the radio 1 Loosen and remove cable clamp by rotating anti clockwise from the PSU port Warning Loosen the cable clamp completely and then unscrew the gland Not releasing the cable may cause damage to the RJ45 socket and or PCB 2 Remove the gland 3 Press tab on RJ45 plug to remove the cable from PSU port ...

Page 37: ... regulations of the country of use Attention As the V5000 3000 60W DC Power Injector and V1000 15 W power injector are not water proof locate it away from sources of moisture either in the equipment building or in a ventilated moisture proof enclosure Do not locate the PSU in a position where it may exceed its temperature rating Attention Plug only recommended Cambium 60 GHz cnWave PSU into the PS...

Page 38: ... network equipment 3 Connect 60 W 56V 5 GbE PoE port of the power injector to ODU drop cable Installing the AC DC PSU 1 Connect input side of the AC DC PSU to AC power line 2 Connect output side of DC PSU to ODU through cable joiner and DC mini adapter Refer 60 GHz cnWave User Guide for connecting installing Cable joiner and Mini adapter Figure 2 AC DC PSU Figure 3 Cable joiner Figure 4 DC to RJ45...

Page 39: ... assembly of cable joiner and mini adapter to ODU PSU port refer 60 GHz cnWave User Guide Installing the V1000 power injector 1 Connect the 56V Gigabit Data power port to ODU and Gigabit Data port to the network equipment Figure 6 V1000 power injector Figure 7 V1000 powering diagram ...

Page 40: ... to the SFP optical module to ODU Fitting the long cable gland Optical SFP interface Disassemble the long cable gland and thread its components over the LC connector at the ODU end as shown below Copper Cat6a SFP interface Disassemble the cable gland and thread its components over the RJ45 connector at the ODU end 1 Disassemble the long cable gland used for optical SFP interface Disassemble the lo...

Page 41: ...SFP module To insert the SFP module into the ODU follow the below steps 1 Remove the blanking plug from the SFP port of the ODU Optical SFP module Copper SFP module 2 Insert the SFP module into the SFP receptacle with the label on bottom Optical Copper ...

Page 42: ...ting the cable Attention The Fiber optic cable assembly is very delicate To avoid damage handle it with extreme care Ensure that the fiber optic cable does not twist during assembly especially when fitting and tightening the weatherproofing gland Do not insert the power over Ethernet drop cable from the PSU into the copper SFP module as this will damage the module ...

Page 43: ...r into the SFP module ensuring that it snaps home Optical Copper Fitting the gland 1 Fit the gland body to the SFP port and tighten it to a torque of 5 5 Nm 4 3 lb ft 2 Fit the gland nut and tighten until the rubber seal closes on the cable Do not over tighten the gland nut as there is a risk of damage to its internal components ...

Page 44: ...Connecting 60 GHz cnWave Products 44 3 Fit the gland nut to the rubble seal on the gland body and tighten it to a torque of 5 5 Nm 4 3 lb ft ...

Page 45: ...tical Copper 2 Pull the bale clasp latch to the unlocked position Extract the module by using a screwdriver Optical Copper Configuration Configuring the management PC 1 Select Properties for the Ethernet port In Windows 7 Windows 10 this is found in Control Panel Network and Internet Network Connections Local Area Connection 2 Select Internet Protocol TCP IP 3 Click Properties 4 Enter an IP addres...

Page 46: ...the power supply AC DC according to configuration refer 60 GHz cnWave User Guide 2 Connect the PC Ethernet port to the LAN port of the PSU or AUX port according to device configuration refer 60 GHz cnWave User Guide 3 Open a web browser and type 169 254 1 1 When prompted enter admin admin to login to the GUI and complete the configuration For complete configuration refer 60 GHz cnWave User Guide ...

Page 47: ...z cnWave V1000 Client Node with China Cord C600500C012A 60GHz cnWave V1000 Client Node with South Africa Cord C600500C013A 60GHz cnWave V1000 Client Node with India Cord C600500C014A 60GHz cnWave V1000 Client Node with no Cord C600500C016A 60GHz cnWave V1000 Client Node with Israel cord Israel Only C000000L137A Universal Pole Mount Bracket for 1 3 diameter poles C000000L136A Universal Wall Mount B...

Page 48: ...tdoor Cable 100m N000082L172B CAT6A Outdoor Cable 305m N000082L174B RJ45 Connector for CAT6A Cable Qty 10 SFP 10G SR 10G SFP MMF SR Transceiver 850nm 40C to 85C SFP 10G LR 10G SFP SMF LR Transceiver 1310nm 40C to 85C N000082L215A Optical CABLE MM 1m N000082L191A Optical CABLE MM 2 2m N000082L192A Optical CABLE MM 10m N000082L193A Optical CABLE MM 20m N000082L194A Optical CABLE MM 30m N000082L195A ...

Page 49: ...r 56V 10 100 1000 BaseT N000082L173A Grounding Kit for CAT5E F UTP 8mm and Cat6A Cable C000000L138A Grounding Cable 0 6m with M6 ring to M6 ring C000000L123A Cable Gland for 6 9mm cable M25 Qty 10 C000000L176A Cable Gland for 4 6mm cable M25 Qty 10 C000000L125A cnWave Precision Mounting Bracket N000045L002A Tilt Bracket Assembly C000000L139A Telescope mounting kit N000900L017A PoE 15 4W 56V GbE DC...

Page 50: ...lossary Term Definition ACM Adaptive Coding and Modulation CN Client Node DN Distribution Node E2E Controller End to End Controller PoP Point of Presence LPU Lighting Protection Unit SFP Small Form factor Pluggable ...

Page 51: ...rks around the world our PMP access network solutions prove themselves day in and day out in residential access leased line replacement video surveillance and smart grid infrastructure applications Cambium Networks solutions are proven respected leaders in the wireless broadband industry We design deploy and deliver innovative data voice and video connectivity solutions that enable and ensure the ...

Reviews: