background image

Chapter 2: Packaging and Installation of Access Point

40

T-Bar mounting

38mm T-Bar:

The e410/e600 can be secured to a 38mm ceiling T-bar rail by using the ceiling mount bracket.

Summary of Contents for cnPilot E410 Indoor

Page 1: ...HARDWARE INSTALLATION GUIDE Enterprise Wi Fi Access Point System Release 6 4 1 ...

Page 2: ... or the 3rd Party software supplied material contained in the Cambium products described in this document may not be copied reproduced reverse engineered distributed merged or modified in any manner without the express written permission of Cambium Furthermore the purchase of Cambium products shall not be deemed to grant either directly or by implication estoppel or otherwise any license under the...

Page 3: ...On Premises 8 Reporting problems 8 Security advice 8 Safety and regulatory information 9 Human exposure to radio frequency energy 10 USA and Canada specific information 11 Federal Communication Commission interference statement 11 Specific expertise and training required for professional installers 12 Avoidance of weather radars 13 Ethernet networking skill 13 Ethernet cabling types 13 Pole or tow...

Page 4: ...g and Installation of Access Point 19 Unpacking the Access Point 19 Package contents 19 Mounting the device 19 Mounting XV3 8 21 Mounting XV2 2 24 Mounting XV2 2T XV2 2T1 28 Mounting XE3 4 34 Mounting e410 e600 38 Mounting e510 42 Mounting e430 44 Mounting e700 49 Cambium Networks 52 ...

Page 5: ...imit Overview of Cambium Networks products This User Guide describes various features supported by Cambium Network s Access Point AP It also provides detailed instructions for setting up and configuring the AP Intended audience The guide is intended to assist system designers system installers and system administrators Purpose This guide intends to instruct and assist personnel in the operation in...

Page 6: ...networks com support warranty Feedback For feedback e mail to support cambiumnetworks com New hardware platforms The System Release 6 4 1 includes support for the following new hardware platform Table 2 New hardware platform Hardware Platform Description XV2 2T1 Outdoor Wi Fi 6 Access point 2x2 Sector antenna Dual band 802 11ax 2x2 BLE 2 5GbE Existing hardware platforms Table 3 lists the existing ...

Page 7: ...in xirrus com respectively Mobile Application AP can be managed by using the Swift application To download the Swift application from App Store scan the QR code and follow instructions Note For cloud and mobile pplication management please ensure the AP has connectivity to the internet Connectivity can be verified using tools such as ping from the Troubleshooting tab of the AP UI Connection status...

Page 8: ... the software release notes of supported releases 2 Visit the Support website http www cambiumnetworks com support 3 Ask for assistance from the Cambium product supplier 4 Gather information from affected units such as any available diagnostic downloads 5 Escalate the problem by emailing or telephoning support https www cambiumnetworks com support contact support Security advice Cambium Network s ...

Page 9: ... grounded to protect against lightning It is the responsibility of the user to install the equipment in accordance with national regulations In the USA follow Section 810 of the National Electric Code ANSI NFPA No 70 1984 USA In Canada follow Section 54 of the Canadian Electrical Code These codes describe correct installation procedures for grounding the outdoor unit mast lead in wire and discharg...

Page 10: ...pplicable when working with RF equipment are l ANSI IEEE C95 1 1991 IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields 3 kHz to 300 GHz l Council recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz 1999 519 EC and respective national regulations l Directive 2004 40 EC of t...

Page 11: ...ed to try to correct the interference by one of the following measures l Reorient or relocate the receiving antenna l Increase the separation between the equipment and receiver l Connect the equipment into an outlet on a circuit different from that to which the receiver is connected l Consult the dealer or an experienced radio TV technician for help Attention Any changes or modifications not expre...

Page 12: ... only for indoor usage to reduce potential for harmful interference to co channel mobile satellite systems les dispositifs fonctionnant dans la bande 5150 5250 MHz sont réservés uniquement pour uneutilisationà l intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de satellites mobiles utilisant les mêmes canaux IC radiation exposure statement This equipment complies with...

Page 13: ... cover the 100m maximum cable length runs For shorter runs under about 30m CAT5E cable is recommended For high radio frequency electric fields environments shielded CAT5E or CAT6 type cabling is recommended For 5Gbps Cambium Networks recommends CAT6 for cable runs under about 50m and CAT6a for lengths over 50m up to the maximum of 100m Shielding cables should be used and the shielded CAT6 CAT6a ne...

Page 14: ...on the wall of a building then in addition to the general protection requirements follow the below requirements also l Ensure that the position of the equipment is lower than the top of the building or its lightning air terminal l Ensure that the building is correctly grounded Connection examples of wall installations are shown in below figure ...

Page 15: ...to the AP Training The installer needs to have basic competence in radio and IP network installation The specific requirements applicable to the Cambium Networks Enterprise Wi Fi AP must be gained by reading this User Guide and by performing sample setups at base workshop before live installments Power density exposure limit This section includes the following topics ...

Page 16: ...alculation of power density and distance The following calculation is based on the ANSI IEEE C95 1 1991 method as that it provides a worst case analysis Details of the assessment to EN50383 2002 can be provided if required Peak power density in the far field of a radio frequency point source is calculated as follows Where l P Maximum average transmit power capability of the radio in W l G total Tx...

Page 17: ...etworks Enterprise Wi Fi AP adheres to all applicable EIRP limits for transmit power when operating in MIMO mode Separation distances and compliance margins include compensation for both transmitters Explanation of terms used in the following tables l P maximum average transmits power of the radio Watt l G total transmit gain as a factor converted from dB l S power density W m l d minimum safe sep...

Page 18: ...C 0 20 0 29 2 4G 5G 33 CE 0 1247 4 548 0 253 2 4G 5G 6G W m 25 e410 FCC 0 2506 0 4998 20 IC 0 54 0 975 2 4GHz 5GHz 20 CE 0 1947 5 737 2 4G 5G W m 20 e510 FCC 0 28 0 65 20 IC 0 22 0 186 20 CE 0 19 7 35 2 4G 5G W m 20 e430 FCC 0 139 0 164 20 IC 0 27 20 CE 0 1935 1 481 2 4G 5G W m 20 e600 FCC 0 168 0 5487 24 IC 0 49 20 CE 0 1375 6 257 2 4G 5G W m 24 e700 FCC 0 39317 0 55028 24 IC 0 45 0 975 2 4G 5G 2...

Page 19: ...listed in Package contents below are included in the package Check each item for damage If any item is damaged or missing notify your authorized Cambium Networks Enterprise Wi Fi AP sales representative Package contents A complete Cambium Networks Enterprise Wi Fi AP package contains all the items listed below 1 Cambium Networks Enterprise Wi Fi AP 2 Quick Start Guide QSG l Specifications l Safety...

Page 20: ...ment Enterprise Wi Fi APs are mounted in the following methods l Wall Mount l Celling Mount l T bar Mount l Pole Mount l Gang mount Table 6 provides an overview of the type of mountings each Enterprise Wi Fi APs supports Table 7 Types of mounting the device Access Point Wall Mount Ceiling Mount T bar Mount Pole Mount Gang Mount Table Mount XV3 8 ü ü ü XV2 2 ü ü ü XV2 2T ü ü XV2 2T1 ü ü XE3 4 ü ü ü...

Page 21: ...nd remove the ceiling tile 2 Using the hole template mark the hole locations 3 Drill the holes for the four mounting screws using a 5mm 3 6 diameter drill bit 4 Drill a hole for the RJ45 cable using a 15 mm 5 8 diameter bit 5 Hold the mounting plate on the top side of the ceiling tile and screw it on the mounting bracket 6 Run the RJ45 cable s through the 15mm hole and remount the ceiling tile 7 A...

Page 22: ...ng two screws with corresponding wall anchors The ceiling mount bracket can be used as a template to align the screws with the unit T bar Mounting The XV3 8 XE5 8 can be secured to a 38mm ceiling T bar rail by using the ceiling mount bracket The A marking on the bracket must be used for this width T bar rail 38mm T Bar ...

Page 23: ...ar rail using the clips built into the underside of the unit The B marking on the bracket must be used for this width T bar rail 14mm T Bar The XV3 8 XE5 8 unit can be mounted to a 14mm width T bar rail using the clips built into the underside of the unit The C marking on the bracket must be used for this width T bar rail ...

Page 24: ... Ceiling mount 1 Determine where XV2 2 needs to be mounted and remove the ceiling tile 2 Using the hole template mark the hole locations 3 Drill the holes for the 4 mounting screws using a 5mm 3 6 diameter drill bit 4 Drill the RJ45 cable hole using a 15 mm 5 8 diameter bit 5 Hold the mounting plate on the top side of the ceiling tile and screw it on the mounting bracket ...

Page 25: ...o the mounting bracket Wall mounting You can mount XV2 2 unit to any wall by using two screws with corresponding wall anchors The ceiling mount bracket can be used as a template to align the screws with the unit T bar mounting The XV2 2 unit can be secured to a 38mm ceiling T bar rail by using the ceiling mount bracket The A marking on the bracket must be used for this width T bar rail ...

Page 26: ...th T bar rail using the clips built into the underside of the unit The B marking on the bracket must be used for this width T bar rail 14mm T Bar The XV2 2 unit can be mounted to a 14mm width T bar rail using the clips built into the underside of the unit The C marking on the bracket must be used for this width T bar rail ...

Page 27: ...Chapter 2 Packaging and Installation of Access Point 27 ...

Page 28: ...XV2 2T XV2 2T1 unit on the wall perform the following steps 1 Drill two holes of each Ø6 mm Ø0 25 Inch on the wall where you want to mount the XV2 2T XV2 2T1 AP 2 Press fit the plastic anchor and assemble fastener 3 Leave 5mm to 6mm gap between the wall and the fastener head as shwon in below figure 4 Use the four mounting slots given on the back of the radio to mount it on the wall 5 Make sure th...

Page 29: ...Chapter 2 Packaging and Installation of Access Point 29 6 Hang the XV2 2T unit to the wall mount bracket and tighten the four screws as shown in below figure ...

Page 30: ...he XV2 2T XV2 2T1 unit on the pole perform the following steps 1 Insert the hose mounting clamp though the pole mounting level bracket 2 Fix the clamp to the pole by applying 9 0 Nm torque 3 Fasten four mounting screws 4 Align the chassis with the guide hole of the pole mounting level bracket and ...

Page 31: ...of Access Point 31 5 Slide it downwards Pole mount with tilt bracket Only for XV2 2T1 To mount the XV2 2T1 unit on the pole perform the following steps 1 Assemble the pole mount holder to XV2 2T1 by using the four M5 screws as shown below ...

Page 32: ...s Point 32 2 Install the pole mount bracket to the pole by using two hose clamps with the 9Nm torque 3 Assemble XV2 2T1 with pole mount holder to pole mount bracket Use M12 stud washer and M12 nut to secure it by applying 3Nm torque as shown below ...

Page 33: ...Chapter 2 Packaging and Installation of Access Point 33 ...

Page 34: ...l Wall mounting or l T bar mounting Ceiling mount To mount the XE3 4 unit by using the ceiling mount technique perform the following steps 1 Determine a place or location where you want to mount the XE3 4 unit 2 Remove the ceiling tile 3 Using the hole template mark the hole locations 4 Drill the holes for the four mounting screws using a 5mm 3 6 diameter drill bit ...

Page 35: ...the ceiling tile 8 Attach the RJ45 cable s to XE3 4 unit 9 Slide XE3 4 unit into the mounting bracket Wall mounting You can mount XE3 4 to any wall by using two screws with corresponding wall anchors The ceiling mount bracket can be used as a template to align the screws with the unit T bar mounting 38mm T Bar The XE3 4 unit can be secured to a 38mm ceiling T bar rail by using the ceiling mount br...

Page 36: ...nd Installation of Access Point 36 24mm T Bar The XE3 4 unit can be mounted to a 24mm width T bar rail using the clips built into the underside of the unit The B marking on the bracket must be used for this width T bar rail ...

Page 37: ...nd Installation of Access Point 37 14mm T Bar The XE3 4 unit can be mounted to a 14mm width T bar rail using the clips built into the underside of the unit The C marking on the bracket must be used for this width T bar rail ...

Page 38: ...ount technique perform the following steps 1 Determine where the AP needs to be mounted and remove the ceiling tile 2 Using the hole template mark the hole locations 3 Drill the holes for the 4 mounting screws using a 5mm 3 6 diameter drill bit 4 Drill the RJ45 cable hole using a 15 mm 5 8 diameter bit 5 Hold the mounting plate on the top side of the ceiling tile and screw it on the mounting brack...

Page 39: ...ch the RJ45 cable to the device 8 Slide the device into the mounting bracket Wall mounting You can mount e410 e600 to any wall by using two screws with corresponding wall anchors The ceiling mount bracket can be used as a template to align the screws with the unit ...

Page 40: ...Chapter 2 Packaging and Installation of Access Point 40 T Bar mounting 38mm T Bar The e410 e600 can be secured to a 38mm ceiling T bar rail by using the ceiling mount bracket ...

Page 41: ...cess Point 41 24mm T Bar The e410 can be mounted to a 24mm width T bar rail using the clips built into the underside of the unit 14mm T Bar The e410 can be mounted to a 14mm width T bar rail using the clips built into the underside of the unit ...

Page 42: ...s Point 42 Mounting e510 The e510 units are mounted by using one of the following mounting techniques l Pole mount l Wall mounting Pole mount Insert hose clamps through pole mounting bracket and clamp to pole by applying 6 0Nm torque Wall mounting ...

Page 43: ...ccess Point 43 1 Drill 4 holes of Ø6mm Ø0 25 Inch on wall 2 Press fit plastic anchor and assembly fastener 3 Leave 5mm to 6mm gap between wall and fastener head 4 Use the four mounting slots given on the back of the radio to mount to the wall ...

Page 44: ...thernet cable to the upper RJ 45 port labelled Eth1 PoE at the rear side of e430 to provide connectivity Use the other RJ 45 port labelled Pass Through for any additional cable that might need to pass through e430 4 Align the two slots at rear side of the e430 with two hooks on the bracket 5 Secure e430 to the bracket with a screw at the bottom edge of e430 using standard Torx security screw or st...

Page 45: ...Chapter 2 Packaging and Installation of Access Point 45 Dual gang mounting 1 Remove dual gang box cover 2 Place Cambium dual gang wall bracket on the gang box and secure with at least two screws ...

Page 46: ... port labelled Eth1 PoE at the rear side of e430 to provide connectivity Use the other RJ 45 port labelled Pass thru for any additional cable that might need to pass through e430 5 Align the two slots at rear side of e430 with two hooks on the bracket 6 Secure e430 to the bracket with a screw at the bottom edge of e430 using standard Philips head or Torx security screwdriver ...

Page 47: ... 1 Choose location on the wall to mount the bracket using the four mounting screws and anchors if needed 2 Connect the short Ethernet jumper cable between the two RJ 45 connections on the rear side of e430 3 Mount e430 into the Generic Wall bracket by aligning the hooks ...

Page 48: ...n of Access Point 48 4 Secure e430 to the bracket using Torx or standard screw on the lower edge of e430 5 Power e430 either with a 48Vdc 1A power adapter or using the PASS THRU port at the bottom edge of the device using Ethernet power ...

Page 49: ...le mount l Wall mounting Pole mount 1 Assemble the radio holder to the pole mounting bracket and secure it with M8 nuts by applying 3 0 Nm torque 2 Insert hose clamps through pole mounting bracket and clamp to pole by applying 6 0 Nm torque 3 Align the radio chassis with the guide rails of radio holder and slide it downwards until it clicks into place ...

Page 50: ...n of Access Point 50 4 Insert RJ45 to radio housing and the lock cable gland to radio housing with 1 5Nm to 2Nm torque 5 Align Radio to required angle by tilting up and down The maximum radio tilting angle is 40 with an incremental of 10 ...

Page 51: ...oint 51 Wall mounting 1 Drill 4 holes of Ø6mm Ø0 25 Inch on wall 2 Press fit plastic anchor and assembly fastener 3 Leave 5mm to 6mm gap between wall and fastener head 4 Use the four mounting slots given on the back of the radio to mount to the wall ...

Page 52: ... connectivity solutions in urban suburban and rural environments with wireless that just works Support website https support cambiumnetworks com Support enquiries Technical training https learning cambiumnetworks com learn Main website http www cambiumnetworks com Sales enquiries solutions cambiumnetworks com Warranty https www cambiumnetworks com support standard warranty Telephone number list ht...