cfgmgr -v >/tmp/cfg.log 2>&1
Should identify the card and configure it.
If cfg.log contains the ID 7710002x and no driver is found,
then the adapter driver is not installed.
During boot, the number displayed when configuring the
adapter is hex 0x911 (FC adapter).
/usr/lpp/cbxfc/mbtest fscsi1
This test code may be used to get fibre channel status from the
adapter or from attached devices. Type the command as above
for a list of subcommands.
/usr/lpp/cbxfc/mbtest fscsi1 fab
This command will list the persistent bindings between SCSI ID
and WWN on adapter scsi1. It will also list the loop ID and
port ID (fabric address) which can change dynamically as
devices are connected or disconnected.
/usr/lpp/cbxfc/mbtest fscsi1 getp
This command will show the fibre channel ports which are
currently logged in to adapter scsi1.
/usr/lpp/cbxfc/sctest fscsi1
This test code may be used to get IOCINFO information from
the adapter or to see the results of SCSI Inquiry or
TestUnitReady commands to SCSI devices attached to the
adapter. Type the command as above for a list of
subcommands.
/usr/lpp/cbxdpf/dpfutil listall
This will list the failover devices and paths. The active path
will be shown on the left. Status is shown by letter codes:
“F’ indicates a failed path.
“O” indicates offline paths.
24